background image

6. TROUBLE SHOOTING

MAINTENANCE

7.  CLEANING & MAINTENANCE

IMPORTANT! 

BEFORE CLEANING YOUR HIGH PRESSURE 

CLEANER OR CARRYING OUT ANY MAINTENANCE 

PROCEDURE, MAKE SURE THAT THE MOTOR IS OFF AND 

THE TOOL DISCONNECTED FROM THE POWER SUPPLY 

TO PREVENT ACCIDENTAL STARTING.

IMPORTANT! 

WAIT UNTIL THE HIGH PRESSURE CLEANER 

HAS COMPLETELY COOLED DOWN. RISK OF BURNS!

Cleaning

•   Keep the safety devices free of dirt and dust as far as possible. 

Wipe the equipment with a clean cloth or blow it with compressed 

air at low pressure.

•   We recommend that you clean the appliance immediately after you 

use it.

•   Clean the appliance regularly with a damp cloth and some soft 

soap. Do not use cleaning agents or solvents; these may be 

aggressive to the plastic parts in the appliance. Ensure that no 

water can get into the interior of the appliance.

•   You must disconnect the hose and any spraying tools from the 

compressor before cleaning. Do not clean the compressor with 

water, solvents or the like.

Testing the water intake filter

Periodically check the intake filter in 

order to prevent clogging, which could 

jeopardize operation of the pump.
To do this, unscrew the connector 

for the water inlet hose from the 

high pressure cleaner and clean the 

exposed inlet sieve under running 

water.

Problem

Cause

Solution

The high pressure 

cleaner does not start

1. No power supply

1.  Check the power 

supply, the power 

plug and the 

socket-outlet.

2.  Insufficient supply 

power

2.  Make sure that 

the extension 

cable is not too 

long.

3.  Outside temperature 

is too low

3.  Never operate 

with an outside 

temperature of 

below 5°c.

4.  Motor is overheated

4.  Allow the motor 

to cool down. 

If necessary, 

remedy the 

cause of the 

overheating.

The motor starts but 

there is no pressure 

build-up

1.  Water intake filter is 

clogged

1.  Clean the water 

intake filter

2.  Air intake in the 

water inlet

2.  Check the supply 

hose and hose 

connectors 

and replace if 

necessary

3.  Water tap closed

3.  Turn open the 

water tap

The operating 

pressure is irregular

1.  Air intake in the 

water inlet

1.  Check the supply 

hose and hose 

connectors 

and replace if 

necessary

Содержание PWVCK-1312

Страница 1: ...maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Austr...

Страница 2: ...an be used for storage of the gun lance and high pressure hose Deck patio cleaner 1 Attach the extension onto the deck patio cleaner 2 Fasten from the underside using the 2 screws provided 3 Attach the rotor arm to the deck patio cleaner and secure by inserting the U clip SETUP PREPARATION ACCESSORIES WARNING ENSURE THE TOOL IS SWITCHED OFF AND DISCONNECTED FROM THE POWER SUPPLY BEFORE PERFORMING ...

Страница 3: ...for proper operation Note A filter is fitted to the inlet connector preventing any debris from entering the pump Inspect and clean the filter before use as insufficient water supply could damage the pump 2 CONNECTIONS Gun and lance 1 Fasten the lance to the gun by pushing and twisting Quick connect system The connections of the accessories are attached with a quick connection system 1 To Connect p...

Страница 4: ...ed to prevent accidental spraying Disengage trigger lock before squeezing trigger Adjustable spray nozzle The shape of the water jet can be adjusted from solid cone or flat fan by turning the nozzle Detergent spray bottle Fill the detergent spray bottle with suitable cleaning agent Note Use only cleaning agents which are expressly suitable for high pressure cleaners The quantity of cleaning agent ...

Страница 5: ...r on the gun until there is a steady flow of water from the nozzle 1 Switch the machine On set the On Off switch to position I On 2 Squeeze trigger to begin spraying 3 When finished set On Off switch to position 0 Off 4 Release built up water pressure by squeezing the trigger 5 Turn water supply off 6 Switch off the mains power supply and remove the electrical plug ...

Страница 6: ...h water solvents or the like Testing the water intake filter Periodically check the intake filter in order to prevent clogging which could jeopardize operation of the pump To do this unscrew the connector for the water inlet hose from the high pressure cleaner and clean the exposed inlet sieve under running water Problem Cause Solution The high pressure cleaner does not start 1 No power supply 1 C...

Страница 7: ...il enquires ozito com au SPARE PARTS min Revolutions or reciprocation per minute l min Litres per minute dB Decibel level psi Pounds per square inch BAR Pressure rating Regulator compliance mark Warning Read instruction manual Hp Horse power Ingress protection from water IPX5 W Watts Alternating current Volts V Hz Hertz Warning High pressure jets can be dangerous if not used properly Do not direct...

Страница 8: ... connection of dust extraction and collection facilities ensure these are connected and properly used Use of dust collection can reduce dust related hazards 4 Power tool use and care a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it was designed b Do not use the power tool if the switch doe...

Страница 9: ... manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Australia New Zealand Head Office 1 23 Letcon Driv...

Страница 10: ... down 2 Insert the castor assemblies into the base of the tank Fitting the Motor 1 When fitting the motor to the tank position it so that the tank securing clips on the motor align with the fastening points on the tank 2 Fasten the tank securing clips to the tank making sure that they lock into place correctly 3 To remove the motor open the tank securing clips and lift the motor out of the tank Fi...

Страница 11: ... wet vacuuming slip the supplied foam filter over the filter basket NOTE Do not use the filter bag and or dust bag when vacuuming liquid Fitting the Filter Bag Vacuuming Dry Matter For dry vacuum cleaning always use the filter bag Mount the filter bag so that no air is sucked through the filter cage without being filtered NOTE Do not use the foam filter when vacuuming dry matter 2 FITTING THE FILT...

Страница 12: ... FOAM IS EMITTED WITH THE EXHAUST AIR WHEN WET VACUUM CLEANING IMPORTANT WHEN WET VACUUMING THE SAFETY FLOAT TURNS OFF THE WET AND DRY VACUUM CLEANER AUTOMATICALLY WHEN THE MAXIMUM LEVEL IS REACHED IMPORTANT THE WET AND DRY VACUUM CLEANER IS NOT SUITABLE FOR THE VACUUMING OF COMBUSTIBLE LIQUIDS PWVCK 1312 On Off Switch Switch position 0 OFF Switch position I ON Dry Vacuuming Use the dust bag and t...

Страница 13: ...e should not be disposed of with household waste but in an environmentally friendly way Please recycle where facilities exist Check with your local council authority for recycling advice Recycling packaging reduces the need for landfill and raw materials Reuse of recycled material decreases pollution in the environment Please recycle packaging where facilities exist Check with your local council a...

Страница 14: ...ngs refers to your mains operated corded power tool or battery operated cordless power tool 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bystanders away wh...