DESCRIPTION OF SYMBOLS
CARING FOR THE ENVIRONMENT
Power tools that are no longer usable should not be disposed of
with household waste but in an environmentally friendly way. Please
recycle where facilities exist. Check with your local council authority
for recycling advice.
Recycling packaging reduces the need for landfill and raw materials.
Reuse of recycled material decreases pollution in the environment.
Please recycle packaging where facilities exist. Check with your
local council authority for recycling advice.
Spare parts can be ordered from the Special Orders Desk
at your local Bunnings Warehouse.
For further information, or any parts not listed here, visit
www.ozito.com.au or contact Ozito Customer Service:
Australia 1800 069 486 New Zealand 0508 069 486
E-mail: [email protected]
SPARE PARTS
ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS
WARNING!
Read all safety warnings and all instructions.
Failure to follow the warnings and
instructions may result in electric shock, fire and/or serious injury.
Save these instructions
1. Work area safety
a.
Keep work area clean and well lit
. Cluttered or dark areas invite accidents.
b.
Do not operate pumps in explosive atmospheres, such as in the presence of flammable liquids,
gases or dust.
Pumps create sparks which may ignite the dust or fumes.
c.
Keep children and bystanders away while operating a pump.
Distractions can cause you to lose control.\
2. Electrical safety
a.
Pump plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs
with earthed (grounded) pumps.
Unmodified plugs and matching outlets will reduce risk of electric shock.
b.
Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and
refrigerators.
There is an increased risk of electric shock if your body is earthed or grounded.
c.
Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the pump. Keep cord
away from heat, oil, sharp edges or moving parts.
Damaged or entangled cords increase the risk of
electric shock.
d.
When operating a pump, use an extension cord suitable for wet conditions.
Use of a cord suitable for
wet use reduces the risk of electric shock.
e.
This pump must be used with a residual current device with rated residual current of 30mA or less.
Use of an RCD reduces the risk of electric shock.
3. Personal safety
a.
Stay alert, watch what you are doing and use common sense when operating a pump. Do not use
a pump while you are tired or under the influence of drugs, alcohol or medication.
A moment of
inattention while operating a pump may result in serious personal injury.
b.
Avoid accidental starting. Ensure the switch is in the off position before plugging in.
Carrying pump
with your finger on the switch or plugging in pumps that have the switch on invites accidents.
c.
Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and
refrigerators.
There is an increased risk of electric shock if your body is earthed or grounded.
d.
When operating a pump outdoors, use an extension cord suitable for outdoor use.
Use of a cord
suitable for outdoor use reduces the risk of electric shock.
4. Pump use and care
a.
Disconnect the plug from the power source before making any adjustments, changing accessories,or
storing pumps.
Such preventive safety measures reduce the risk of starting the pump accidentally.
b.
Maintain pumps. Check for misalignment or binding of moving parts, breakage of parts and any other
condition that may affect the pumps operation. If damaged, have the pump repaired before use.
Many
accidents are caused by poorly maintained pumps.
c.
Use the pump, and accessories etc., in accordance with these instructions and in the manner
intended for the particular type of pump, taking into account the working conditions and the work to
be performed.
Use of the pump for operations different from intended could result in a hazardous situation.
5. Service
a.
Have your pump serviced by a qualified repair person using only identical replacement parts.
This will
ensure that the safety of the pump is maintained.
b.
If the supply cord is damaged,
it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
GENERAL SAFETY WARNINGS
ELECTRICAL SAFETY
WARNING!
This product is intended for pumping water in a Home Domestic application. Do
not use it for corrosive, abrasive, explosive or dangerous liquids. Fluids other than water will
damage the water pump and/or create a fire hazard.Failure to follow all instructions listed below
may result in electric shock, fire and/or serious injury.
WARNING!
This product is not suitable for use with drinking (potable) water.
This appliance is not intended for use by person (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
• Ensure the water pump is disconnected from mains power when installing.
• Do not install or operate the water pump in an explosive environment or near flammable material.
• Do not operate the water pump without liquid.
• Do not run the water pump dry.
WARNING!
The water pump together with associated pipework operate under pressure. Do not
disconnect water pump or pipework until internal pressure has been released. Failure to do this
could result in personal injury and damage to property.
• Avoid inserting hands into the inlets/outlets of the water pump while it is connected to power.
• Before using the water pump, always inspect it visually. Do not use the pump if it is cracked and/or damaged.
If the water pump is damaged, contact Ozito customer service.
• The water pump has a built-in thermal protection overload switch. The water pump stops if an overload
occurs. The motor restarts automatically after it has cooled down.
• The pump must not be used when people are in the water.
• Never work or perform maintenance on the pump without first making sure it has been disconnected from the
mains power.
• Pollution of the liquid could occur due to leakage of lubricants Important:
Avoid inserting hands into the mouth of the pump if it is connected to the mains.
The electrical connection must always be made in a dry area. Make sure that electrical connections are protected
from inundations.
Protect the plug and the power cable from heat, oil or sharp edges.
If damaged, The power cable must be replaced by a qualified electrician.
WARNING!
When using mains-powered tools, basic safety precautions, including the
following, should always be followed to reduce risk of fire, electric shock, personal injury and
material damage
.
Read and understand the manual prior to operating this pump
.
Save these instructions and other documents supplied with this pump for future reference. The electric motor has
been designed for 230V and 240V only. Always check that the power supply corresponds to the voltage on the
rating plate
.
Note:
The supply of 230V and 240V on Ozito pumps are interchangeable for Australia and New Zealand. This
pump is earthed in accordance with AS/NZS 60335-2-41.
Note:
The power outlet used for the water pump must be protected by a 30mA residual current device or earth
leakage circuit breaker. If the power outlet is external, ensure that it is weather proof. If the supply cord is
damaged, it must be replaced by an electrician or a power tool repairer to avoid a hazard. The water pump has
a built-in thermal protection overload switch. The water pump stops if an overload occurs. The motor restarts
automatically after it has cooled down.
Using an Extension Lead
Always use an approved extension lead suitable for the power input of this product. Before use, inspect the
extension lead for signs of damage, wear and ageing. Replace the extension lead if damaged or defective. Then
using an extension lead on a reel, always unwind the lead completely. Use of an extension lead not suitable for
the power input of this product or which is damaged or defective may result in a risk of fire and electric shock.
V
Volts
Hz
Hertz
~
Alternating current
W
Watts
/min
Revolutions or
n
o
No load speed
reciprocation per minute
l
Litres
ºC
Degrees celsius
p/hr
Per hour
kPa
Pressure rating (kilopascals)
bar
Pressure rating
F
Insulation class
PVC
Polyvinyl chloride
IPX8
Ingress protection from water
Regulator compliance mark
Warning
Read instruction manual