background image

7 • Oz Charge manual 

 www.ozcharge.com.au

STEP 4 - Disconnecting the Battery charger from Battery

• 

If the Battery is out of the vehicle:

  

(1) Switch OFF and Remove the AC Power Socket from the outlet.

      

(2) Remove the Black lead and then the Red lead.

• 

If  the battery is still in the vehicle:

  

(1) Switch OFF and Remove the AC Power Socket from the outlet.

  

(2) Remove the lead from the vehicle chassis.

  

(3) Remove the lead from the battery.

Note: Check electrolyte levels if possible after charging as they may need topping up with distilled 
water. (This does not apply to sealed maintenance free batteries)

LED STATUS INDICATOR TABLE:

LED

Status

Description

Power  / Fault LED – Green / Red

Green

ON

AC power is connected

Green

Flash

ECO mode and no battery connected

Red

ON

Short circuit / reverse polarity connection

Red

Flash (Slow) Automatic Rejuvenation or charge cycle has timed out

Red

Flash (Fast) Over temperature protection mode

Charge /  Reconditioning LED – Blue  / Yellow

Blue

Flash

Rejuvenation (Reconditioning)  or  Soft start charging

Blue

ON

Bulk charge  or Absorption charging

Yellow

ON

Battery is flat (less than 3V) or Battery failed analysis test

 Full LED -Green

Green

ON

Fully charged - Float / Maintenance mode

RED

BLACK

RED

BLACK

CONNECTION

 

IN

 

VEHICLE

(

NEGATIVELY

 

EARTHED

)

RED

BLACK

CONNECTION

 

IN

 

VEHICLE

(

POSITIVELY

 

EARTHED

)

Содержание OC121.5

Страница 1: ...RED BLACK CONNECTION IN VEHICLE NEGATIVELY EARTHED RED BLACK CONNECTION IN VEHICLE POSITIVELY EARTHED OWNER S MANUAL Model OC121 5 Australian New Zealand STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...k medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or b...

Страница 3: ...left on 24 7 to ensure your battery is always maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor...

Страница 4: ...rity SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthecharger frombeingdamagedifthepositiveandnegati...

Страница 5: ...ture 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 140mm x 65mm x 35mm Weight 0 45kg Approvals CE UL cUL AS NZS EMC CHARGING INSTRUCTIONS STEP 1 Pre charge check ele...

Страница 6: ...sitively or negatively earthed If Negatively Earthed Most Common FIRST Connect the Red Crocodile clip or ring terminal lead to the positive battery terminal and then connect the Black Crocodile clip o...

Страница 7: ...esn t reach 9V within 24 hours the Rejuvenation process will time out 3 Soft Start Charging Blue Charging LED Flashing Gently charges the battery using a reduced charge output until the battery voltag...

Страница 8: ...topping up with distilled water This does not apply to sealed maintenance free batteries LED STATUS INDICATOR TABLE LED Status Description Power FaultLED Green Red Green ON AC power is connected Gree...

Страница 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE...

Страница 10: ...ocodile clips ring terminals are connected to the correct polarity Note The charger output is only present when connected to a battery No charging current Fault Red LED is Flashing Battery is severely...

Страница 11: ...a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods...

Страница 12: ...OC121 5 Owner s Manual Rev 1 1 11 14 Specifications subject to change without notice SAAApproval No GMA 102826 EA 001...

Отзывы: