background image

TECHNICAL SPECIFICATIONS:

Model Number 

OC-RM800i

Output

12V DC / 800A Max.

Input Voltage

3V - 15.5V

Battery Capacity

8,000mAh (Lithium Titanate)

Standby Current Consumption

5mA max. / 0.1mA Typical

Emergency Start Switch Activation 3V to 13.5V
Accepts Charging

>13.5V

Over Voltage Cut Off Protection

14.3V

Operating Temperature

-20 to 80 C° 

IP Rating

IP65

Operating Humidity

90% RH Max.

Size (L*W*H)

224 x 154 x 103mm

Weight

2.9kg approx.

Approvals

FCC, AS/NZS CISPR 32:2015, EN55032:2015, 
EN55024:2010+A1:2015

INPUTS / OUTPUTS:

1) LED/Switch  - 

Push Button LED. Activates the On-board Emergency Starter Output.

2) Remote Switch/LED Input - 

The Remote Switch/LED connects here. Activates the On-

board Emergency Starter Output.

3) Battery Connection 

- Connect to main starter battery.

1

2

3

2 • OzCharge manual   

www.ozcharge.com.au

Содержание OC-RM800i

Страница 1: ...OWNER S MANUAL Model OC RM800i On Board Emergency Starter...

Страница 2: ...ing cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to use this device on a damaged battery frozen battery or non rechar...

Страница 3: ...peratingTemperature 20 to 80 C IP Rating IP65 Operating Humidity 90 RH Max Size L W H 224 x 154 x 103mm Weight 2 9kg approx Approvals FCC AS NZS CISPR 32 2015 EN55032 2015 EN55024 2010 A1 2015 INPUTS...

Страница 4: ...ted next to your starter battery It connects directly to your battery and provides power for starting your engine jump starting your vehicle when required If theVehicle doesn t start simply press the...

Страница 5: ...unless you press the Emergency Start Switch again to deactivate the units output Red Flash The LED will flash RED when the vehicles battery voltage is under 10 5V TROUBLE SHOOTING Problem Indication...

Страница 6: ...manual www ozcharge com au UNIT DIAGRAM MEASUREMENTS 103mm 224mm 154mm 150mm 100mm Positive connection must be fused Use existing vehicle fuse or add a 350A Mega Fuse by Littlefuse Hole Size for LED S...

Страница 7: ...of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclus...

Страница 8: ...OC RM800i Owner s Manual Rev 1 0 06 18 Specifications subject to change without notice...