background image

6 • Oz Charge manual   

www.ozcharge.com.au

STEP 4 - Plug the battery charger back into Mains Power (240Vac)

• 

The charger will automatically start when AC power is connected and switched on.     

Once the charger is switched on, please check the correct battery type is selected as 

per STEP 1.         

Note:

 If all LED’s flash when turned on, please check your connections as it’s likely that 

the Positive and Negative Leads are reversed. Refer to Trouble Shooting Page for further 

information.

THE CHARGING PROCESS: LEAD ACID

1)  Automatic Rejuvenation - Orange Charging Blinking

If the initial qualification detected that the battery was in poor condition, the automatic 

rejuvenation process will begin automatically. During the rejuvenation process a high voltage 

equalising and 16V peak pulse reconditioning charge is used to repair the sulphated battery. 

This unique patented feature will break down and dissolve the lead-sulphate crystal build up 

on the battery plates which will extend the life of your battery. It can also balance out high 
concentrations of acid. This feature is time limited and will transit to Soft Start after 24 hours.

2)  Soft Start Charging - Orange Charging Flashing

Gently charges the battery using a reduced charge output until the battery voltages reaches 
10V.   If the battery voltage doesn’t reach 10V within 24 hours, the safety timer protection will 
stop the unit from charging and the Charging, Full and Lead Acid LED’s will all flash.

3)  Bulk Charging - Orange Charging LED ON

Uses the maximum charge output (0.8A) until the battery voltage reaches 14.4V.                                        
If the battery voltage doesn’t reach 14.4V within 48 hours, the safety timer protection will stop 
the unit from charging and the Charging, Full and Lead Acid LED’s will all flash.

4)  Battery Cell Check - Cell Analysis

During Bulk Stage, the charger will check and analyses the battery condition to determine 
whether the battery contains a dead/shorted cell. If this analysis fails, the Charging, Full and 
Lead Acid LED’s will all flash.

5)  Absorption Charging - Orange Charging LED ON

Uses a constant voltage of 14.4V while reducing the charging output current to ensure the 
battery receives a full charge without overcharging the battery. 

6)  Sulphation Check Battery Analysis - Orange Charging LED ON

The battery analysis stage checks the condition of the battery after the charge cycle is 
completed. If the battery voltage drops too quickly during the analysis mode, this means the 
battery is probably faulty. This is indicated by the Green Full LED flashing.

7)  Float Mode - Full Green LED ON

This stage allows you to keep the charger connected 24/7 to ensure your battery is well 
maintained and kept 100% fully charged. Float mode will maintain the battery at a constant 
13.6V.

Содержание OC-PRO80L

Страница 1: ...OWNER S MANUAL Model OC PRO80L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...een dropped or damaged Do not attempt to use the charger if the cables or plugs are damaged If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualifi...

Страница 3: ...conditioningtorepairsulphatedbatteries Thisfeatureisfullyautomaticand dependsontheinternalimpedanceofthebattery Lead AcidModeOnly Can be left on 24 7 to ensure your battery is always maintained and fu...

Страница 4: ...ON The charger output will be disabled if the output leads are short circuited Thispreventsthechargerfrombeingdamagedifthepositive andnegativecrocodileclipsorringterminalsaccidentallytoucheachotherwhi...

Страница 5: ...ZS EMC CHARGING INSTRUCTIONS STEP 1 DETERMINE AND SELECTYOUR BATTERYTYPE BEFORE CONNECTINGTHE CHARGERTOYOUR BATTERY PLUG IN CHARGER ANDTURN AC POWER ON ONCE THE CORRECT BATTERYTYPE IS SELECTED SWITCH...

Страница 6: ...ttery is out of the vehicle ConnecttheRed Orange Crocodileclip orringterminaltothepositive battery terminal ConnecttheBlack Crocodileclip orringterminaltothenegative battery terminal If Negatively Ear...

Страница 7: ...ttery voltage doesn t reach 10V within 24 hours the safety timer protection will stop the unit from charging and the Charging Full and Lead Acid LED s will all flash 3 Bulk Charging Orange Charging LE...

Страница 8: ...thout overcharging the battery 5 Absorption Charging Stage 2 Orange Charging LED ON Steps up the constant voltage to 14 4V while reducing the charging output current to ensure the battery receives a f...

Страница 9: ...ON OFF ON Absorption Charging ON OFF ON Bad Cell Sulphated battery Reverse Polarity Soft Start or Bulk Charging time out error Flash Flash Flash Full Float mode OFF ON ON Final Analysis check fail OF...

Страница 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVES...

Страница 11: ...Check that the crocodile clips ring terminals are connected to the correct polarity Note The charger output is only present when connected to a battery The full light won t come on All LED s are flas...

Страница 12: ...the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accepts no respon...

Отзывы: