background image

3 • Oz Charge manual 

 www.ozcharge.com.au

TEMPERATURE & SAFETY PROTECTION: 

• 

INTERNAL OVERHEAT PROTECTION: 

The charger has a built-in overheat and 

an overload electronic circuit. This protects the charger from being damage if 

overheated or overloaded and will automatically decrease the charging current. 

Once the units internal temperature decreases to a safe level, the charger will 

resume normal charging. 

• 

SAFETY TIMER PROTECTION: 

The charger has safety timers for every stage. If 

the battery voltage doesn’t reach a certain voltage within a certain time, the unit 

will stop charging as it’s highly likely that you’re attempting to charge a severely 

discharged or heavily sulphated battery. If any of the stages time out, the charger 

will immediately stop charging in order to protect the battery and the Charging, Full 

and selected Battery Type LED’s will all flash.

• 

REVERSE POLARITY: 

The charger has reverse polarity protection. If the charger 

output leads are connected reverse polarity, the Charging, Full and selected Battery 

Type LED’s will all flash and the charger will be disabled. Simply unplug  the charger 

from AC power and then connect the output leads to the correct polarity.

• 

SHORT CIRCUIT PROTECTION: 

The charger output will be disabled if the output 

leads are short circuited. This prevents the charger from being damaged if the positive 

and negative crocodile clips or ring terminals accidentally touch each other while the 

charger is turned on.

• 

ECO MODE: 

This Oz Charge battery charger has a built in ultra low power 

consumption circuit. If AC power is connected and the battery is disconnected, 

after 10 seconds the charger will automatically go into an ECO mode. 

During this mode the power drawn is less than 0.36W which totals 0.01kWh 

per day power consumption. If AC power is connected and the battery 

is connected, once the battery is fully charged and during the long term 

maintenance  stage,  the  total  power  consumption  is  around  0.03kWh  per  day.                                                                                 

(Lead Acid Mode Only)

 The Lead Acid battery type LED will flash when in Eco Mode.

BATTERY TYPES & CAPACITY:

• 

S

uits 12V conventional lead acid type batteries (VRLA) AGM, EFB, Gel & Wet and 

compatible 

Lithium-ion (including LiFePO4) batteries

. It can also be used as a 

maintenance charger only for Calcium SMF batteries if required in Lead Acid mode.

• 

The Ah (Ampere-hour) capacities shown below are to be used as a general guide only.

Some batteries may be able to handle a higher charge current. Refer to the battery 

manufacturers specifications and recommendations for your charging requirements. 

Battery Capacity: Charging

2 - 20Ah (150 CCA)

Battery Capacity: Maintaining

2 - 80 Ah (600 CCA)

Содержание OC-PRO80L

Страница 1: ...OWNER S MANUAL Model OC PRO80L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...een dropped or damaged Do not attempt to use the charger if the cables or plugs are damaged If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualifi...

Страница 3: ...conditioningtorepairsulphatedbatteries Thisfeatureisfullyautomaticand dependsontheinternalimpedanceofthebattery Lead AcidModeOnly Can be left on 24 7 to ensure your battery is always maintained and fu...

Страница 4: ...ON The charger output will be disabled if the output leads are short circuited Thispreventsthechargerfrombeingdamagedifthepositive andnegativecrocodileclipsorringterminalsaccidentallytoucheachotherwhi...

Страница 5: ...ZS EMC CHARGING INSTRUCTIONS STEP 1 DETERMINE AND SELECTYOUR BATTERYTYPE BEFORE CONNECTINGTHE CHARGERTOYOUR BATTERY PLUG IN CHARGER ANDTURN AC POWER ON ONCE THE CORRECT BATTERYTYPE IS SELECTED SWITCH...

Страница 6: ...ttery is out of the vehicle ConnecttheRed Orange Crocodileclip orringterminaltothepositive battery terminal ConnecttheBlack Crocodileclip orringterminaltothenegative battery terminal If Negatively Ear...

Страница 7: ...ttery voltage doesn t reach 10V within 24 hours the safety timer protection will stop the unit from charging and the Charging Full and Lead Acid LED s will all flash 3 Bulk Charging Orange Charging LE...

Страница 8: ...thout overcharging the battery 5 Absorption Charging Stage 2 Orange Charging LED ON Steps up the constant voltage to 14 4V while reducing the charging output current to ensure the battery receives a f...

Страница 9: ...ON OFF ON Absorption Charging ON OFF ON Bad Cell Sulphated battery Reverse Polarity Soft Start or Bulk Charging time out error Flash Flash Flash Full Float mode OFF ON ON Final Analysis check fail OF...

Страница 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVES...

Страница 11: ...Check that the crocodile clips ring terminals are connected to the correct polarity Note The charger output is only present when connected to a battery The full light won t come on All LED s are flas...

Страница 12: ...the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accepts no respon...