6 • Oz Charge manual
www.ozcharge.com.au
THE CHARGING PROCESS:
1) Bulk Charging - (C
harge Voltage depends on battery type selection)
Uses the maximum charge output until the battery voltage reaches a selected voltage. If the
battery voltage doesn’t reach this within 24 hours, the safety timer protection will stop the unit
from charging and LED 4 will be flashing.
2) Absorption Charging
Uses a constant voltage while reducing the charging output current to ensure the battery
receives a full charge without overcharging the battery.
3) Equalisation Charging
A well proven process that carefully overcharges the battery to restore it’s full capacity. The
Equalisation charge voltages are shown in the specifications on Page #3.
4) Float Mode - Fully Charged
This stage allows you to keep the charger connected 24/7 to ensure your battery is well main-
tained and kept 100% fully charged. Float mode will maintain the battery at a constant 13.6V.