OzCharge OC-DC1215 Скачать руководство пользователя страница 5

4 • Oz Charge manual   

www.ozcharge.com.au

Please ensure you have adequate cable size for the output cables. If the output cables are too small, 
the voltage drop across the cable will cause the battery not to be charged at the correct voltage. 
Voltage drop isn’t as critical on the input side, so the cable size can be a little smaller.
The ON/OFF (Switched Ign) wire can be 0.8mm / 18AWG .
Please refer to our recommendations below.

Input Battery Cables

Output Battery Cables

Cable Length

Minimum Cable Size

Cable Length

Minimum Cable Size

< 1.0m

1.3mm

/ 16AWG

< 0.5m

1.3mm

/ 16AWG

< 2.0m

1.6mm

/ 15AWG

< 1.0m

2.6mm

2

/ 14AWG

< 3.0m

2.1mm

/ 14AWG

< 1.5m

3.8mm

2

/ 12AWG

< 6.0m

2.6mm

2

/ 13AWG

< 2.0m

5.1mm

2

/ 11AWG

Input 9-16 VDC

Output 12 VDC 15 A

Please read the instructions before using.

Disconnect Input before connecting/

disconnecting the output.

Warning: Explosive gases may escape

from battery during charging.

12 Volt / 15 AmpsDC/DC Battery Charger

Designed for all lead acid sealed 

(Calcium, AGM, GEL & WET) batteries.

Std

AGM

Ca

Gel

Mode

Status

Starter Battery

Auxilary Battery

Fuse

30A

Fus

e

20A

Swithed
12V (IGN)

GND

WIRING DIAGRAM:

CABLE SIZE GUIDE:

Содержание OC-DC1215

Страница 1: ...OWNER S MANUAL OWNER S MANUAL Model OC DC1215 12V 15A DC DC Battery Charger Suitable for all Conventional lead acid batteries VRLA AGM CALCIUM GEL WET...

Страница 2: ...1 Oz Charge manual www ozcharge com au...

Страница 3: ...ning cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable batt...

Страница 4: ...ol dry area The Input connections are made to the vehicles battery alternator the ON OFF input needs to be connected the vehicles IGN wire or it can be controlled by a manual ON OFF switch The ON OFF...

Страница 5: ...put Battery Cables Cable Length Minimum Cable Size Cable Length Minimum Cable Size 1 0m 1 3mm2 16AWG 0 5m 1 3mm2 16AWG 2 0m 1 6mm2 15AWG 1 0m 2 6mm2 14AWG 3 0m 2 1mm2 14AWG 1 5m 3 8mm2 12AWG 6 0m 2 6m...

Страница 6: ...fault LED will come on Thispreventsthechargerfrombeingdamagedif thepositiveandnegativeoutputaccidentlytoucheachotherwhilethechargeristurnedon BATTERY TYPES CAPACITY Suits 12V conventional lead acid ba...

Страница 7: ...rption Charging Uses a constant voltage while reducing the charging output current to ensure the battery receives a full charge without overcharging the battery 3 Equalisation Charging A well proven p...

Страница 8: ...Description 1 ON Std BatteryType Selected 2 ON AGM GEL BatteryType Selected 3 ON Calcium Calcium BatteryType Selected 4 Flashing Charger has time out 4 5 7 ON Bulk Charging Rolling 4 5 6 7 ON Absorpt...

Страница 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVES...

Страница 10: ...t are connected to the correct polarity Check for Loose connections Check the ON OFF connection has 12V IGN No charging current Fault Red LED 8 is ON Battery is severely sulphated Battery has a damage...

Страница 11: ...copy of their receipt for proof of purchase It is recom mended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods...

Страница 12: ...OC DC1215 Owner s Manual Rev 1 2 04 15 Specifications subject to change without notice...