background image

1 • Oz Charge manual   

www.ozcharge.com.au

Congratulations on purchasing the Oz Charge PX2408M fully automatic switched mode  

24 Volt / 8 Amp battery charger and maintainer.  Please take the time to carefully read and 

understand this manual before using this product.

IMPORTANT SAFETY ADVICE AND WARNINGS

• 

The charger is designed to charge and maintain conventional lead-acid batteries 

only. (VRLA), AGM, GEL & WET.

• 

Always refer to the battery manufacturers specifications and recommendations if 

you’re unsure of your battery charging requirements. E.g. Such as removing or not 

removing cell caps whilst charging.

• 

Explosive gases may escape from the battery during charging so please ensure the 

battery is charged in a well ventilated area.

• 

This charger is designed for indoor use only and should never be exposed to water, 

rain, snow, liquids etc.

• 

Do not attempt to use the charger if it has been dropped or damaged.

• 

Do not attempt to use the charger if the cables or plugs are damaged.

• 

If battery acid contacts your skin or clothing, wash immediately with soap and water. 

If acid enters your eye, immediately flush the eye with running cold water for at least 

10 minutes and seek medical attention. Someone should always be within range of 

your voice.

• 

Never attempt to charge a damaged battery, frozen battery or non rechargeable 

battery. 

• 

Never place the charger on the battery or battery on the charger. 

• 

When working with lead-acid batteries, remove personal metal items such as rings, 

bracelets, necklaces, watches and make sure you don’t short circuit the battery 

terminals with any type of metal tool or piece of jewellery as this will cause an 

explosion. You can wrap your spanner with insulation tape to minimise the risk of a 

short circuit.

• 

NEVER smoke, use an open flame or create sparks near a battery or charger during 

charging operation as this may cause an explosion and explosive gases.

• 

Do not disassemble the charger. Take it to a qualified and authorised person for 

repair.

• 

If using a generator, you must ensure you use a surge protector to protect the 

charger from voltage spikes.

• 

The charger must not be used or played with by infirm persons or children. Also 

keep it away from any pets.

Содержание PX2408M

Страница 1: ...OWNER S MANUAL Model PX2408M AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Страница 2: ......

Страница 3: ...n or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead...

Страница 4: ...e your battery is always maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance Short circuit and reverse polarity protection The PX2408M will recharge the battery set to 80 of the rated capacity in a period not exceeding 8 hours IP51 rate...

Страница 5: ...top charging in order to protect the battery This will be indicated with the fault LED flashing REVERSE POLARITY The charger has reverse polarity protection If the charger output leads are connected reverse polarity the fault LED will come on and the charger will be disabled SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED wil...

Страница 6: ...40Vac 1 6A Input Frequency 50 60Hz ChargeVoltage 29 0V FloatVoltage 27 4V StartVoltage 3V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 185mm x 153mm x 70mm Weight 1 7kg Approvals CE AS NZS EMC CONTROL AND INDICATORS 1 Charging status Display LED Fault RED refer to LED STATUS indicatorTABLE on page 6 Charging Process Orange Fully Charged Gree...

Страница 7: ...each 23V within 4 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashing 2 Bulk Charging Orange Charging LED ON Uses the maximum charge output 8A until the battery voltage reaches 29 0V If the battery voltage doesn t reach 29 0V within 16 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashin...

Страница 8: ... ON OFF Fully Charged Float Trickle maintenance charging OFF OFF FLASH 1 Output lead short reverse polarity OFF OFF FLASH 2 Soft Start ChargeTimed Out OFF OFF FLASH 3 Bulk ChargeTimed Out OFF OFF FLASH 4 Overheat Protection Mode OFF OFF ON Weak Faulty Battery Poor initial current acceptance CHARGING CURVE SOFT START BULK CHARGE ABSORPTION FLOAT Increases your battery life by gently starting to cha...

Страница 9: ...eckthatthereareno foreignobjectsinsidethe3 PinXLRconnectors Checkthatthe3PinXLRplugs havebeensecurely connected CheckthattheXLRplugshave notbeenforcedtogether incorrectly Movechargertoacoolerarea RefertoLEDIndicatorTable Nocharging current FaultLEDisON Batteryisseverely sulphated Batteryhasadamagedcell ChecktheBatterycondition ageetc Batterymayneed replacement Longcharging time Fulllight doesnot c...

Страница 10: ... a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Страница 11: ......

Страница 12: ...PX2408M Owner s Manual Rev 1 2 12 14 Specifications subject to change without notice SAAApproval No 111981EA 001 ...

Отзывы: