background image

 

 
 

Oz Charge GRUNT Series Workshop Charger Owner’s Manual  - V1.0 08/16

 

 

OZ CHARGE GRUNT SERIES – WORKSHOP BATTERY CHARGER 

TECHNICAL SPECIFICATONS 

 

Dimensions (L x W x H) 

294 x 135 x 94.5 mm 

Weight 

 

2,2 Kg (without cables) 

Ambient temperature 

– 20

o

C > +50

o

Mains voltage 

240VAC  

Rated charging current 12V 

120A Max. / 100A continuous (OC-W12120P)  
70A Max. / 60A continuous (OC-W122470P) 

Rated charging current 24V 

60A (OC-W122470P) 

Fluctuation 

< 3% 

Charging voltage AGM/Gel 

14.4 VDC for 12V batteries 

 28.8 VDC for 24V batteries 

Charging voltage Standard/SMF Calcium  14.7 VDC for 12V batteries 

 29.4 VDC for 24V batteries 

Maintenance charging 

13.8 VDC for 12V batteries 

 27.6 VDC for 24V batteries 

Start Voltage 

8.2 / 8.4 VDC for 12V batteries 

 16.4 / 16.8 VDC for 24V batteries 

Power Supply Mode 

13.7VDC 100Amps (OC-W12120P) / 13.7VDC 60Amps (OC-W122470P) 

Frequency on supply voltage (AC) 

45 Hz to 65 Hz 

Standby current from the battery 

< 2 mA 

Recommended mains fuses 

C10 

Mains cables 

Rubber cable with Neutrik coupler & Schuko plug. 1.5m 

Battery cables available -  

2 x 25mm

2

 3m with terminal clamps 200A (OC-W12120P) 

2 x 10mm

2

 3m with terminal clamps 200A (OC-W122470P) 

IP Code 

IP21 (When mounted vertically) 

Housing 

Aluminum 

General 

Protection against wrong polarity and short circuits. CE-certified in 
accordance with valid EN-standards. 
AS/NZS 60335.2.29 and EMC Approved 

 

TYPES, CELLS & RATED CAPACITY

 

MODEL 

DESCRIPTION 

NUMBER OF CELLS 

RATED CAPACITY 

OC- W122470P 

12V – 70A / 24V – 60A 

6/12 

Up to 1000Ah 

OC-W12120P 

12V – 120A 

Up to 1500Ah 

 

Suitable for conventional lead acid type batteries only (VRLA) AGM, Calcium, Gel & Wet. 
Always refer to the battery manufacturers specifications and recommendations for your charging requirements. 

Содержание OC-W12120P

Страница 1: ...OWNER S MANUAL Model OC W12120P 12V 120A Model OC W122470P 12V 70A 24V 60A ...

Страница 2: ...r battery 3 Connecting the battery charger to Mains Power 240Vac 3 CONTROL LAMPS ERROR DESCRIPTIONS 4 CHARGING PROCESS 4 CHARGING CURVES 5 Charging curve Standard batteries 5 Charging curve GEL AGM batteries Error Bookmark not defined TECHNICAL SPECIFICATONS 6 TYPES CELLS RATED CAPACITY 6 TROUBLESHOOTING 7 MAINTENANCE AND SERVICE 8 Regular inspections 8 MOUNTING 9 2 YEAR PRODUCT WARRANTY 10 WHAT S...

Страница 3: ...d never be exposed to water rain snow liquids etc Do not attempt to use the charger if it has been dropped or damaged Do not attempt to use the charger if the cables or plugs are damaged If battery acid contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Some...

Страница 4: ...r or fuel lines If Positively Earthed FIRST Connect the Black Crocodile clip or optional ring terminal lead to the battery terminal and then connect the Red Crocodile clip or optional ring terminal lead to the vehicle s chassis DO NOT connect the Red lead to the carburetor or fuel lines Connecting the battery charger to Mains Power 240Vac The charger will automatically start when AC power is conne...

Страница 5: ...V Please ensure you ve selected the correct charge output to suit your application Bulk Charge Charging with constant current Orange LED lights up The maximum charging current is used to charge the battery depending on its charged status so as to store as much energy as quickly as possible in the battery If a battery that has been totally discharged is attached to the charger the charger will star...

Страница 6: ...disconnected CHARGING CURVES The Workshop Charger is designed for charging 12V 24V OC W122470P model open and valve regulated batteries of different sizes Refer to the charging graphs below for the different charge modes Note The equalisation charge only occurs if the Standard battery type option is selected Charge Graph POWER SUPPLY MODE 13 7VDC The Workshop Chargers have a 13 7VDC power supply m...

Страница 7: ... batteries Power Supply Mode 13 7VDC 100Amps OC W12120P 13 7VDC 60Amps OC W122470P Frequency on supply voltage AC 45 Hz to 65 Hz Standby current from the battery 2 mA Recommended mains fuses C10 Mains cables Rubber cable with Neutrik coupler Schuko plug 1 5m Battery cables available 2 x 25mm2 3m with terminal clamps 200A OC W12120P 2 x 10mm2 3m with terminal clamps 200A OC W122470P IP Code IP21 Wh...

Страница 8: ...lack Yellow AC plug connected Is the charger plugged into the socket Please check again Orange LED is only dimly lit If Orange LED is definitely not lit up please contact the service team Lock Neutrik Black Yellow AC plug Plug charger into socket Switch on the mains fuse 1 Check if the battery is in Maintenance Charging mode 2 Check if correct Battery voltage type has been selected Is the mains fu...

Страница 9: ... the charger externally undamaged and unopened Have you ensured that the charger is not in contact with water oil or other liquids WARNING Always check the charger and the cable for damage each time before using the device Do not use a damaged device or a device with a damaged attachment cord Have this fixed immediately Always have the device checked if it has come into contact with liquids Have t...

Страница 10: ...batteries The charger must be protected against the effects of dust and moisture Ensure that the fan can freely suck in cooling air Do not install the charger directly next to or above flammable materials Mount the charger on an even horizontal or vertical surface The four openings on the rubber feet are used for mounting the charger Please use bolts of 5 mm diameter Example of mounting the charge...

Страница 11: ... shipment To prove that the product is under warranty the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product ...

Страница 12: ......

Отзывы: