background image

6 • Oz Charge manual   

www.ozcharge.com.au

THE CHARGING PROCESS:

1)  Qualification - Battery Condition Check

When the charger is first switched on it checks the battery condition to determine whether the 
battery needs reconditioning. During this qualification process it checks the internal impedance 
and initial voltage of the battery and it will determine how much charge current, if any that the 
battery will accept. 

2)  Automatic Enhanced Battery Rejuvenation - Blue Bulk LED Flashing Fast

If the initial qualification detected that the battery was in poor condition, the patented 
rejuvenation process will begin automatically. During the rejuvenation process a high voltage 
equalising and peak pulse reconditioning charge is used to repair the sulphated battery. 
This unique patented feature will break down and dissolve the lead-sulphate crystal build up 
on the battery plates which will extend the life of your battery. It can also balance out high 
concentrations of acid. The equalisation voltage will be 16V maximum. If the battery voltage 
doesn’t reach 9V within 24 hours, the Rejuvenation process will time out.

Manual  Enhanced Rejunvenation Mode

To manually rejuvenate your batteries, simply press and hold both the Battery Type and Charge 
Rate buttons simultaneously for 3 seconds until the Blue Bulk LED flashes rapidly. This mode will 
last for 24 Hours. To stop rejuvenation mode, press and hold both the Battery Type and Charge 
Rate buttons simultaneously for 3 seconds until the Blue Bulk LED stops flashing rapidly.

Important Note:

 Please check your Battery Type and Charge Rate selection to ensure you 

haven’t accidentally changed these settings.

3)  Soft Start Charging - Blue Bulk LED Flashing Slow

Gently charges the battery using a reduced charge output until the battery voltages reaches 
11V. If the battery voltage doesn’t reach 11V within 6 hours, the safety timer protection will stop 
the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing.

4)  Bulk Charging - Blue Bulk LED ON

 (Charge Voltage depends on battery type selection)

Uses the maximum selected charge output until the battery voltage reaches 14.1/14.4/14.7V. If 
the battery voltage doesn’t reach this within 24 hours, the safety timer protection will stop the 
unit from charging and the Red Fault LED will start flashing and the Blue Bulk LED will be ON.

5)  Absorption Charging - Green Absorption LED ON

Uses a constant voltage while reducing the charging output current to ensure the battery 
receives a full charge without overcharging the battery. 

6)  Equalisation Charging - Blue Bulk LED and Green Absorption LED both flashing 

A well proven process that carefully overcharges the battery to restore it’s full capacity. The 
Equalisation stage for CALCIUM Battery type selection is automatic. The Equalisation stage for 
AGM&WET and GEL Battery Types only occurs if the initial start voltage is below 11 Volts.

7)  Battery Analysis - Green Full LED ON

The battery analysis stage checks the condition of the battery after the charge cycle is 
completed. If the battery voltage drops too quickly during the analysis mode, this means the 
battery is probably faulty.  If the battery analysis failed, this is indicated by the Green Full LED 
flashing.

Содержание OC-PRO1200

Страница 1: ...AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED STATE OF CHARGE I N D I C A T O R STATE OF CHARGEI N D I C A T O R I N C LUDED OWNER S MANUAL Models OC PRO600 OC PRO1200 AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Страница 2: ...ater for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don t short circ...

Страница 3: ...ys maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance with a special pulse charge during long term maintenance Short circuit and reverse polarity protection Heavy duty and corrosion resistant output connectors Crocodile clips and ring ...

Страница 4: ... charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthechargerfrombeingdamaged ifthepositiveandnegativecrocodileclipsortheoptionalringterminalsaccidentlytoucheach otherwhilethechargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power consumption circuit If AC power is connected and the battery is dis...

Страница 5: ...Voltage 13 6V 13 6V StartVoltage 3V 3V OperatingTemperature 15 to 50 C 15 to 50 C StorageTemperature 25 to 85 C 25 to 85 C Operating Humidity 90 RH Max 90 RH Max Size L W H 182mm x 88mm x 48mm 214mm x 103mm x 55mm Weight 0 75kg 1 1kg Approvals CE UL cUL AS NZS EMC CE UL cUL AS NZS EMC CHARGING INSTRUCTIONS STEP 1 Pre charge check electrolyte level check Check the Battery Electrolyte levels Not req...

Страница 6: ...nal ring terminal lead to the vehicle s chassis DO NOT connect the Red lead to the carburettor or fuel lines STEP 3 Connect the battery charger to Mains Power 240Vac The charger will automatically start when AC power is connected and switched on IMPORTANT Please make sure the correct BatteryType and your desired Charge Rate is selected to suit your battery by pressing the Select Buttons within the...

Страница 7: ... rapidly Important Note Please check your BatteryType and Charge Rate selection to ensure you haven t accidentally changed these settings 3 Soft Start Charging Blue Bulk LED Flashing Slow Gently charges the battery using a reduced charge output until the battery voltages reaches 11V If the battery voltage doesn t reach 11V within 6 hours the safety timer protection will stop the unit from charging...

Страница 8: ... topping up with distilled water This does not apply to sealed maintenance free batteries LED STATUS INDICATOR TABLE LED Status Description BatteryTypeLED s Green ON Indicates which BatteryType is selected ChargeRateLED s Green ON Indicates which Charge Rate Charge Mode is selected ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance mode Abs...

Страница 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE Can also be activated manually ...

Страница 10: ...battery No charging current Fault Red LED is Flashing Battery is severely sulphated Battery has a damaged cell Overheat protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Battery Ah capacity too large for the battery charger and it ha...

Страница 11: ... a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Страница 12: ...altothePositive batteryterminal 2 ConnecttheBlackringterminaltotheNegative batteryterminal 3 Pressthebuttontocheckbatterycondition Trouble shooting advice if NO LED s come on when Button is pressed 1 Batterylevelisbelow3V 2 CheckFuseonringterminalharness 3 Checkconnectionofringterminalsand2pinconnectors GreenLEDmeans BatteryOK 12 5V RedLEDmeans Batteryneedscharging 12 5V Note Foruseon12Voltbattery...

Отзывы: