7

AI

R
FLO

W

12

34

56

78

Burner

Assembly

Finish

Flange

Igniter

Roll-Out

Switch

Gas Valve

Furnace

Control Board

Condensate

Pressure

Switches

Transformer

Motor

Control

Board

Blower

Assembly

Motor Choke

(C & D cabinets only)

Blower Door

Switch

Inducer

Assembly

Inducer

Pressure

Switches

Motor

Control Box

Inducer

Limit Switch

Main Air

Limit Switch

Burner

Assembly

Flame

Sensor

Roll-Out

Switch

Finish

Flange

Blower Assembly

(behind blower panel)

Blower

Door Switch

(behind blower panel)

Motor Choke

(C & D cabinets only)

Gas

Manifold

Gas Valve

Igniter

Inducer

Assembly

Inducer Limit

Switch

Main Air

Limit Switch

Furnace

Control

Board

Motor

Control

Board

Pressure

Switches

Transformer

FLOW

AIR

J952V*U 

Upflow / Horizontal

Condensing Gas Furnace

J962V*D 

Downflow

Condensing Gas Furnace

Flame

Sensor

Gas

Manifold

COMPONENT LOCATIONS FOR TWO-STAGE FURNACES

STARTING THE FURNACE

1.  Make sure the filter is clean and in place.

2.  Make sure the vent system is properly installed.

3.  Set the thermostat to the lowest setting.

4.  Close the manual gas valve outside the furnace.

5.  Turn off all electric to the furnace.

6.  Remove the door from the burner compartment.

7.  Set the gas valve switch or knob to the OFF position. 

See Figure 1 for gas valve switch or knob location.

8.  Wait 5 minutes. If there is any smell of gas, see “WHAT 

TO DO IF YOU SMELL GAS” on page 4.

9.  Set the gas valve switch or knob to the ON position.

10.  Turn on all electric to the furnace.

11.  Open the manual gas valve.

12.  Turn the thermostat back up to force ignition.

13.  Observe operation, including burners. If burners fail to 

ignite, call a licensed HVAC technician.

14.  Replace the door on the burner compartment.

Figure 1. Gas Valves

SINGLE STAGE VALVE

TWO - STAGE VALVE

STARTUP & SHUTDOWN

SHUTTING DOWN THE FURNACE

IMPORTANT! IF YOU NEED TO SHUT DOWN YOUR 

FURNACE FOR SERVICE OR MAINTENANCE, SHUT OFF 

THE GAS VALVE TO THE FURNACE BEFORE TURNING 

OFF THE ELECTRICAL SERVICE.
NOTE:

 Your furnace may be equipped with one of three 

types of gas valves. Remove the door panel from the front 

of the furnace and determine which valve type matches your 

installation in Figure 1. Move the switch to the OFF Position.
If your installation has a manual gas shutoff valve on the 

gas supply pipe, shut this off, then shut off the electric to 

the furnace.
1.  Set the thermostat to the lowest setting.

2.  Close the manual gas valve outside the furnace.

3.  Turn electric to the furnace off.

4.  Open the door to the burner compartment.

5.  Set the gas valve switch or knob to the OFF position.

6.  Replace the door on the burner Compartment.

Содержание J801X D Series

Страница 1: ...tallation and service must be performed by a qualified installer service agency or the gas supplier Donotstoreorusegasolineorotherflammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas su...

Страница 2: ...RODUCTION 5 CATEGORY I NON CONDENSING FURNACES 5 CATEGORY IV CONDENSING FURNACES 5 FILTER 5 THERMOSTAT 5 FURNACE LOCATION 5 COMPONENT LOCATIONS FOR SINGLE STAGE FURNACES 6 COMPONENT LOCATIONS FOR TWO STAGE FURNACES 7 STARTUP SHUTDOWN 7 STARTING THE FURNACE 7 SHUTTING DOWN THE FURNACE 7 MAINTENANCE INSPECTION 8 FURNACE AIR DUCTS 8 VENTING SYSTEM 8 BLOWER FILTER 8 BURNER OPERATION 8 NEW CONSTRUCTION...

Страница 3: ...ve been wet or the furnace if deemed necessary Safety markings are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored WARNING indicates a potentially hazardous situation that if not avoided could result in personal injury or death CAUTION indicates a potentially hazardous situation that if not avoided may result in minor or moderate injur...

Страница 4: ...nd glues Antistatic fabric softeners Masonry acid washing materials CAUTION This furnace requires unrestricted airflow for combustion and ventilation For proper and safe operation it is extremely important that the furnace receives an unobstructed flow of clean fresh air to properlyburnthefuelgas Ifthisflowofairisrestricted the partially burned combustion gases may create dangerous amounts of carb...

Страница 5: ...st maintain a downward slope to ensure proper condensate drainage Condensate must flow freely during furnace operation The homeowner must make sure the condensate drain lines do not become blocked pinched or crushed If the furnace is installed in an area where temperatures fall below freezing special precautions must be made for insulatingcondensatedrainlinesthatdraintotheoutdoors If condensate fr...

Страница 6: ...al Non Condensing Gas Furnace J801X D Downflow Non Condensing Gas Furnace Furnace Control Board Burner Assembly Finish Flange Flame Sensor Igniter Roll Out Switch Gas Valve Furnace Control Board Condensate Pressure Switch Transformer Blower Assembly Blower Door Switch Inducer Assembly Inducer Pressure Switch Inducer Limit Switch Main Air Limit Switch Burner Assembly Flame Sensor Roll Out Switch Fi...

Страница 7: ... or knob to the OFF position See Figure 1 for gas valve switch or knob location 8 Wait 5 minutes If there is any smell of gas see WHAT TO DO IF YOU SMELL GAS on page 4 9 Set the gas valve switch or knob to the ON position 10 Turn on all electric to the furnace 11 Open the manual gas valve 12 Turn the thermostat back up to force ignition 13 Observe operation including burners If burners fail to ign...

Страница 8: ...orontheblowerandmotoraspartoftheannualinspection Keepairfilterscleaned Itisrecommendedthatthefurnace airfilterbecheckedatleastonceamonth Cleanorreplace filter to maintain proper airflow and achieve maximum efficiency Furniture and drapery should be arranged so that the supply air registers and return grilles are not obstructed BURNER OPERATION Performthestartupinstructionsonpage7 Theignitershould ...

Страница 9: ...gns of physical deterioration of the furnace X X X Verify no obstructions or restrictions in vent or chimney X X Verify no holes or cracks in vent pipe X X Verify no corrosion in vent pipe X X Verify the horizontal vent pipes slope upwards away from furnace X X Verify burner flame X Clean or replace filter s X Clean blower compartment X Clean burner assembly X Clean condensate collection disposal ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ... 02 20 10270340 NEW ...

Отзывы: