INTRODUCTION
PRECAUTIONS
Operational
- It is important to keep connector ferrules and optical connector ports clean. If dirt, dust, and oil are allowed to build up
inside connector ports, irreparable damage may occur to the optics inside the port. For best results, replace dust caps after each use.
Input Connector
- Do NOT insert APC (Angled Physical Contact) connectors into the input port of the MPO switch as this may
damage the angled ferrule on the APC connector.
Safety
- Exercise caution when working with any optical equipment. High-intensity fiber optic laser sources output potentially
dangerous high energy invisible light, and could cause serious, irreparable damage to the eye. Thus, it is recommended to
NEVER
look into the connector port of a light source or the end of a fiber.
On the back of each DataCenter 12 MPO Optical Switch are labels similar to the one shown below containing model number, serial
number, power requirements, and special cautionary information.
PRODUCT LABEL
MADE IN USA
MODEL# MPO-OSW
SERIAL# OSWS9999
Conforms to the Harmonized
European Standards EN
61326-1 and EN 61010-1.
POWER: 5V DC, 1A
DataCenter 12
MPO Optical Switch