TAKE LOSS MEASUREMENTS
TEST PROCEDURES
14
2) Remove the center (unpinned-to-unpinned) cable
3) Insert the next cable under test, then press TEST.
The screen will begin populating with loss measurement data.
TESTING MPO CABLES
Optical Switch
MPO OWL
Optical Source
MPO OWL
AUTO
PINNED-TO-PINNED
TYPE B
PINNED-TO-PINNED
TYPE B
MPO ADAPTER TYPE B
TEST
LENGTH
ZERO
SAVE
LOSS
MPO OM3
MPO LOSS / OWL
M=ER R=WA
MPO
dB Power @
OPM OLS
PORT 850nm 1300nm
0
1 0.00
0.00
2 0.00
0.00
3 0.00
0.00
4 0.00
0.00
5 0.00
0.00
6 0.00
0.00
7 0.00
0.00
8 0.00
0.00
9 0.00
0.00
10 0.00
0.00
11 0.00
0.00
12 0.00
0.00
N/A BY: --.--
MPO ‘B’
EIA/TIA 568C.3 CON: 2 SPL: 0
50.0um CS1 LEN: 0m
HELP
ENTER
Optical Switch
MPO OWL
Optical Source
MPO OWL
AUTO
PINNED-TO-PINNED
TYPE B
PINNED-TO-PINNED
TYPE B
MPO ADAPTER TYPE B
TEST
LENGTH
ZERO
SAVE
LOSS
Testing...
MPO LOSS / OWL
M=ER R=WA
MPO
dBm Power @
OPM OLS
PORT 850nm 1300nm
0
1 -0.51
-0.98
2 -0.48
-0.76
3 -0.01
-0.52
4 -0.20
-0.48
5 -0.01
6
7
8
9
10
11
12
N/A BY: --.--
MPO ‘B’
EIA/TIA 568C.3 CON: 2 SPL: 0
50.0um CS1 LEN: 0m
HELP