CASUAL FIRESIDE

BTU ÉVALUATION 

Propane Liquide 60,000 / Gaz Naturel 60,000

Tested & Certified to

 ANSI Z21.97-2017/CSA 2.41-2017

CGA 2.17-M91 (R2017)

DANGER

ATTENTION

Une installation, un réglage, une modification, un entretien ou une maintenance incorrects de cet appareil à gaz 
peuvent provoquer des blessures, la mort ou des dégâts matériels. Lisez attentivement les instructions 
d'installation, d'utilisation et de maintenance avant d'installer ou de réparer cet appareil à gaz.

ATTENTION

Ne stockez pas et n'utilisez pas d'essence ou d'autres liquides ou vapeurs inflammables à proximité de 
cet appareil ou de tout autre appareil. Une bouteille de propane liquide non connectée pour être utilisée ne 
doit pas être rangée à proximité de cet appareil ou de tout autre appareil.

ATTENTION : POUR L'EXTÉRIEUR UNIQUEMENT

L’installation et l’entretien doivent être effectués par un installateur qualifié, une agence de service ou le fournisseur de gaz.

Le lien ci-dessous vous mènera aux propriétaires Manuel et instructions en français où vous pouvez télécharger une copie .
Sélectionnez le lien ci-dessous pour télécharger les instructions françaises.

INSTALLATEUR 

- Laissez ce manuel avec 

l'appareil.

CONSOMMATEUR

 

- Conservez ce manuel 

pour référence ultérieure.

DANGER DE MONOXYDE DE CARBONE

Cet appareil peut produire du monoxyde de carbone qui 
n'a pas d'odeur.

Son utilisation dans un espace clos peut vous tuer.

N'utilisez jamais cet appareil dans un espace clos tel 
qu'une caravane, une tente, une voiture ou à la maison.

4. Après avoir quitté les lieux, appelez votre 
fournisseur de gaz ou le service d'incendie.

        DANGER

Cet appareil à gaz est conçu comme un «appareil surveillé». Les adultes doivent être présents lorsque 
l'unité est en fonctionnement / en train de brûler. 

NE laissez PAS cet appareil fonctionner / brûler sans 

surveillance.

 Si ce produit reste en fonctionnement / brûle sans surveillance, il peut provoquer des 

blessures graves, la mort ou des dégâts matériels.

EXIGENCES DE CODES ET D'ALIMENTATION : Lorsqu'un appareil est conçu pour un raccordement à un système de 
tuyauterie fixe, l'installation doit être conforme aux codes locaux ou, en l'absence de codes locaux, au "National Fuel Gas 
Code" (Code national du gaz, É.-U.), à  ANSI Z223.1/NFPA 54, Code international du gaz, L'installation de gaz naturel et de 
propane codes, CSA B149.1,ou propane entreposage et de manutention Code B149.2, le cas échéant.

LISEZ ATTENTIVEMENT CES INSTRUCTIONS AVANT D'INSTALLER CETTE PUITS D'INCENDIE EXTÉRIEUR.

Si les informations contenues dans ce manuel ne sont pas suivies à la lettre, un incendie ou une explosion peut
en résulter. blessures personnelles, décès ou dommages matériels.

1. Coupez l'alimentation en gaz de l'appareil.
2. Éteignez toute flamme nue
3. Si l'odeur persiste, quittez immédiatement la zone.

RISQUE D'INCENDIE OU D'EXPLOSION

Si ces précautions ne sont pas 
respectées, cela pourrait provoquer un 
incendie ou une explosion, pouvant 
causer des blessures, la mort ou des 
dégâts matériels.

V7-100120A

Содержание CASUAL FIRESIDE 5110-42BTO-E

Страница 1: ...ONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT If the information in this manual is not followed exactly a fire or explosion may result causing personal injury death or property damage INSTALLER Le...

Страница 2: ...800 776 9533 Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab f...

Страница 3: ...NSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue...

Страница 4: ...g put into operation if it is evident that the burner is damaged Replacement burner COM0590A manufactured by O W Lee Company 1822 E Francis Street Ontario CA 91761 M DO NOT store any combustible mater...

Страница 5: ...o be used must be provided with a listed overfilling prevention device OPD and with a cylinder connection device compatible with the connection for the appliance 6 The LP Gas Cylinder must be standing...

Страница 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Страница 7: ...0 Thermocouple 11 Electronic Igniter 12 Spark Electrode 13 Pebble Glass Kit Size 3 4 1 2 9 19mm 14 Crushed Fire Glass Kit Size 1 2 3 4 12 20 mm 15 Mirrored Glass Kit Size 1 4 6 35mm 16 Lava Granules 3...

Страница 8: ...Outdoor Fire Pit so that the burner is covered by 1 2 and spread evenly NOTE See Page 7 For Protective Screen Media Clearance See Figure 1 and 2 Figure 1 Pour the first bag of the lava granules media...

Страница 9: ...for proper air flow Note See Page 7 for Protective Screen Media Clearance CAUTION BURN HAZARD LAVA GRANULES CERAMIC LOGS and CERAMIC ROCKS WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN TH...

Страница 10: ...fferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correct...

Страница 11: ...tructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any ou...

Страница 12: ...tank valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve l...

Страница 13: ...rnia for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemic...

Страница 14: ...he orifice holder Figure 1 and unscrew the orifice holder from the burner pipe Figures 1 and 2 This Conversion should only be performed by a Qualified Service Technician or Licensed Plumbe MANUFACTURE...

Страница 15: ...nnez le lien ci dessous pour t l charger les instructions fran aises INSTALLATEUR Laissez ce manuel avec l appareil CONSOMMATEUR Conservez ce manuel pour r f rence ult rieure DANGER DE MONOXYDE DE CAR...

Страница 16: ...LEMENT CET APPAREIL DOIT TRE INSTALL AU MOINS 60 PO DU CENTRE DU BR LEUR TOUT MURS PLAFONDS OU MAT RIAUX COMBUSTIBLES LORSQUE VOUS TEIGNEZ L APPAREIL VEILLEZ COMMANDER LA VANNE DE CONTR LE DU PUITS D...

Страница 17: ...gales 3 5 kPa psi D NE PAS UTILISER L APPAREIL SI LA PRESSION DU GAZ EST INF RIEURE AU MINIMUM EXIG OU D PASSE LE MAXIMUM E POUR LE GAZ NATUREL La pression minimale d admission du gaz pour les besoins...

Страница 18: ...MENT NE PAS laisser en fonctionnement sans surveillance AVERTISSEMENT Une installation un r glage une modification un entretien ou une maintenance incorrects peuvent causer des blessures ou des dommag...

Страница 19: ...le raccordement de l appareil 3 Assurez vous que l appareil n est PAS utilis et fermez le robinet de gaz au robinet d alimentation de la bouteille de gaz LP 4 La bouteille de gaz LP doit tre d branch...

Страница 20: ...ne fuient pas avant d allumer l appareil Le contact avec le liquide contenu dans la bouteille provoquera des br lures de la peau dues au gel Ne laissez pas les enfants alt rer ou jouer avec le cylind...

Страница 21: ...ontr le Soupape n 5 Ligne Flex 22 Chuchotement Silencieux n 6 Connecteur de bouteille de propane n 7 Orifice de propane n 8 Kit de conversion de gaz propane en gaz naturel n 9 cran de protection n 10...

Страница 22: ...ra chaud pendant un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAINTE...

Страница 23: ...LA DISPOSITION APPROPRI E UTILISEZ LA CHALEUR GANTS R SISTANTS OU PERMETTRE AU MAT RIEL UN TEMPS APPROPRI DE SE REFROIDIR AVANT MANIPULATION ATTENTION les granules de lave utilis es dans un foyer sont...

Страница 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Страница 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Страница 26: ...ontr le du foyer ainsi que la vanne du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la...

Страница 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Страница 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Отзывы: