background image

Figure 1,

Placez le plus gros rondin en 

diagonale centré du brûleur.

Figure 2,

S'il vous plaît les trois plus gros 

journaux comme désiré en utilisant le 

plus grand journal comme support.

Figure 3,

Placez la balance des journaux comme 

vous le souhaitez. Assurez-vous de 

partir assez d'espace pour une bonne 

circulation d'air.

Figure 1,

Versez les granules de lave 

dans le support de brûleur 

couvrant le brûleur 

complètement.

Figure 2,

Placez les plus gros rochers 

permettant pour un bon flux d'air.

Figure 3,

Lay the smaller rocks on top

of the larger rocks allowing gaps

for proper air flow.

Page 9

PLACEMENT DE SUPPORTS DE JOURNAUX EN CÉRAMIQUE

Placement de la roche en céramique

(Voir les figures 1, 2 et 3)

ATTENTION:

 DANGER D'URNE. GRANULES DE LAVE, BÛCHES DE CÉRAMIQUE et ROCHES DE CÉRAMIQUE.  

 Restera chaud pendant un certain temps après utilisation..

VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQUÉE POUR ASSURER LE BON FONCTIONNEMENT DE 

VOTRE PUITS.  SI VOUS DEVEZ REPOSER TOUT MATÉRIAU POUR MAINTENIR LA DISPOSITION APPROPRIÉE, 

UTILISEZ LA CHALEUR GANTS RÉSISTANTS OU PERMETTRE AU MATÉRIEL UN TEMPS APPROPRIÉ DE SE 

REFROIDIR AVANT MANIPULATION.

ATTENTION: 

les granules de lave utilisées dans un foyer sont poreuses et chauffées à la température de fonctionnement 

normale peut provoquer une expansion des gaz piégés ou de l’humidité et provoquer un "éclatement" et un "lancement" à 

pourrait causer des blessures ou des dommages matériels. Laissez les granules de lave sécher complètement après 

avoir été mouillées avant de les allumer et en utilisant le foyer.

PLACEMENT DE SUPPORTS DE JOURNAUX EN CÉRAMIQUE

Placement de la roche en céramique

(Voir les figures 1, 2 et 3)

Remarque: voir page 7 pour le dégagement de l'écran protecteur

Remarque: voir page 7 pour le dégagement de l'écran protecteur

Содержание CASUAL FIRESIDE 5110-36RDO

Страница 1: ...l and Operating Instructions in French where you can download a copy S lectionnez le lien ci dessous pour t l charger les instructions fran aises A HIGHER STANDARD IN QUALITY AND APPEARANCE SAFE AND B...

Страница 2: ...nces to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensi...

Страница 3: ...NSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue...

Страница 4: ...g put into operation if it is evident that the burner is damaged Replacement burner COM0595A manufactured by O W Lee Company 1822 E Francis Street Ontario CA 91761 M DO NOT store any combustible mater...

Страница 5: ...o be used must be provided with a listed overfilling prevention device OPD and with a cylinder connection device compatible with the connection for the appliance 6 The LP Gas Cylinder must be standing...

Страница 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Страница 7: ...all four sides as shown above Page 7 REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER 1 Stainless Steel X Burner 2 Propane Regulator 3 On Off Control Knob 4 Brass Control Valve 5 W...

Страница 8: ...Outdoor Fire Pit so that the burner is covered by 1 2 and spread evenly NOTE See Page 7 For Protective Screen Media Clearance See Figure 1 and 2 Figure 1 Pour the first bag of the lava granules media...

Страница 9: ...for proper air flow Note See Page 7 for Protective Screen Media Clearance CAUTION BURN HAZARD LAVA GRANULES CERAMIC LOGS and CERAMIC ROCKS WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN TH...

Страница 10: ...fferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correct...

Страница 11: ...tructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any ou...

Страница 12: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMA...

Страница 13: ...various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals Thes...

Страница 14: ...k by using a liquid soapy solution on all connections before placing the unit in operation 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE TH...

Страница 15: ...rence ult rieure DANGER DE MONOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer N utilisez jamais cet appareil...

Страница 16: ...ILISATION INCORRECTE OU UTILIS E DE VOTRE PUITS D INCENDIE EXT RIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES LA PROPRI T EN CAS D INCENDIE DE BR LURES D EXPLOSIONS OU D EMPOISONNEMENT...

Страница 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Страница 18: ...llation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr que...

Страница 19: ...nne filet s doivent tre bien install s dans les bouteilles d connect es et ne doivent pas tre entrepos s dans un b timent un garage ou un autre espace clos 6 La bouteille de gaz GPL doit reposer sur l...

Страница 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Страница 21: ...DISPONIBLES CHEZ VOTRE CONCESSIONNAIRE LOCAL n 1 X Burner en acier inoxydable n 2 Tuyau de r gulateur de propane de 4 n 3 Bouton de contr le On Off marche arr t n 4 Bras De Contr le Soupape n 5 Ligne...

Страница 22: ...cher compl tement apr s avoir t mouill es avant de les allumer et en utilisant le foyer PLACEMENT DE SUPPORTS EN VERRE GEM MIROIR ET BROY PLACEMENT DE SUPPORTS DE JOURNAUX EN C RAMIQUE Versez les gra...

Страница 23: ...stera chaud pendant un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAI...

Страница 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Страница 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Страница 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Страница 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Страница 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Отзывы: