5.5.2
P
EAK
Button
Tapping this button will move the cursor to the highest peak as determined by the software.
The distances displayed under
the pipe model will give an estimate of leak position from each transmitter.
Drag the line
to move the cursor manually.
“O
ut of brackets” indicates the correlation peak is at or beyond one of the sensor positions. Most
likely the pipe model has not been entered accurately, or the velocity being used is incorrect. Check
the accuracy of the measurement of the pipe model and then perform a Velocity Correction.
5.5.3
SUPPRESS
Button
If an area of excess noise is shown on the correlation display it can be suppressed. This could be a known noise from water
consumption, a valve, flowmeter etc.
5.5.3.1
Turn Noise Suppression On
To suppress an area of noise, tap the SUPPRESS Button
.
To position the area of noise suppression, touch the screen in the
required location, and drag over the noise.
The suppressed area will be shown in grey. Only one noise
suppression area can
be active on each correlation.
Содержание Eureka5
Страница 1: ...Version 1 3 Eureka5 User Manual 24 March 2022 CXD 930 UM 044...
Страница 6: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 6 of 50 11 Appendix E EU DoC 49...
Страница 11: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 11 of 50...
Страница 39: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 39 of 50 Tap Automatic to change to manual filter selection...
Страница 48: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 48 of 50 10 Appendix D UKCA DoC TBA...
Страница 49: ...Eureka5 User Manual CXD 930 UM 044 Version 1 3 Page 49 of 50 11 Appendix E EU DoC TBA...