E-73-2-E
Jumper
Input pulse mode (pulse generator)
J1
Voltage pulse (Code 3 only): 2 Others: 1
● Output Setting:
Establish output mode.
Jumper
Output mode
One-shot output
Upper cutoff output
Duty sync with input
1:1 output
J2
OPEN
CLOSE
OPEN
J4
2
2
1
J5
OPEN
CLOSE
● Output Pulse Width Setting and Adjustment:
Jumper
Pulse width adjust range (adjustable with P1)
Location
J3
OPEN:0.3 to 12ms CLOSE:5.0 to 250ms
TP1and 0VB
(If output mode is “Duty sync with Input 1:1
”,
it adjustment is correct at 1 ms. )
8. INDIVIDUAL JUMPER SETTING
●
Input Setting:
Establish input pulse mode.
Establish parameters such as “ON” width or cutoff width of output pulse signal.
8.1 Enclosure Removal
(1) Unlatch the locks of socket assembly,
separate the distributor body and remove
the enclosure (see Fig. 8.1).
(2) Referring to the pictorial drawing showing
component locations (Fig. 7.1) on page 5,
make adjustments required.
Enclosure
Lock Lever
Surface Mount
Socket
Fig. 8.1