3. INSTALLATION

3.1 Outline Dimensions

3.2 Installation
3.2.1 Installation Location

Select an installation site where:

(1) Mechanical  vibration,  shock  and  corrosive  gases  are 

negligible.

(2) Air  is  dry  and  temperature  at  room  temperature  and 

stable.

NOTE:  Although  the  manufacturer  guarantees  stated 

performance  at  ambient  temperatures  up  to 

50

°

C

 it is recommended that the instrument 

be placed in service at room temperature.

(3) Provide  a  sufficient  working  space  behind  the  instru-

ment  -  at  least  50  centimeters  from  the  back  panel  of 

the instrument to facilitate wiring and servicing.

3.2.2 Panel

(1) Use a rigid steel sheet with a minimum thickness of 1.6 

millimeters. 3.2mm thick is recommended.

(2) If  it  is  required  to  install  instruments  alongside  each 

other, dimensions in Fig.3.2 are suggested.

(3) Recommended mounting height is given in Fig. 3.3.

3.2.3 Installation

(1) Front  mount  the  instrument  through  the  cutout  in  the 

panel.

(2) Fit  the  furnished  enclosure  hold-down  fittings  into  the 

top  and  bottom  slots  in  the  enclosure  and,  confirming 

that the instrument is positioned horizontal, secure the 

instrument to the panel with hold-down fittings (Fig. 3.1).

Optimum

Range

600

1800

450

Acceptable Range

2200

Computer

Fig. 3.1  Outline Dimensions

All dimensions in millimeters

Hold-down Fitting

Min.120

Min.220

92 ±0.8

0

  

+1

138

0

Fig. 3.2 Panel Cut

Fig. 3.3 Instrument Mounting Height

Содержание EL4301

Страница 1: ...of these instruments Keep this manual for ready reference It is suggested that the instruction manuals for the companion pulse generator flowmeter and receiving instrument be referred to at the same...

Страница 2: ...OMPONENTS AND FUNCTIONS 12 6 1 Front Panel 12 6 1 1 Display 12 6 1 2 Front Panel Keypad 12 6 1 3 Error Messages 12 6 1 4 Display Items 13 7 CALCULATION FORMULAS 15 8 PREPARATIONAL CHECKS AND OPERATION...

Страница 3: ...170 9 ABOUT EL4501 175 10 DIP SWITCH CONFIGURATION 182 Model with communication capabilities COMMUNICATION MANUAL Ins No E 880CM E CONTENTS 1 COMMUNICATION CAPABILITY OVERVIEW 5 2 NETWORK CONFIGURATI...

Страница 4: ...d 11 When you inquire supply complete infor mation as to the product name model number product number ratings and other pertinent information 1 2 Transportation Precautions 1 In order to safeguard aga...

Страница 5: ...nd provide an analog output EL4321 EL4331 This instrument receives density frequency signal from the density sensor and provides an analog output in proportion to the density of metered process fluid...

Страница 6: ...0 centimeters from the back panel of the instrument to facilitate wiring and servicing 3 2 2 Panel 1 Use a rigid steel sheet with a minimum thickness of 1 6 millimeters 3 2mm thick is recommended 2 If...

Страница 7: ...r circuits to minimize the possibility of inductive interference 3 Using crimp type lugs for wiring ensure good electrical coannections Terminals are found on the back of the instrument Fig 4 1 4 3 De...

Страница 8: ...3 0V 14 0V 4 OUT 1 1 15 5 b Temp in 16 6 B 17 Temp in 7 A 18 Comm 1 8 19 9 20 Comm 2 10 Alarm out 21 11 NOTE Model provided with communication interface NOTE If transmitter MT9411 temperature termina...

Страница 9: ...Pulse out 3 No polarity Alarm out Static relay 11 12 Density in SUP 13 SIG Tube period signal 5V square wave 14 0V TB2 No Label Description 1 2 3 4 Analog out Instant solids content flow 4 to 20mADC...

Страница 10: ...Code Description Model E L 4 3 1 1 Density Computer for Mass Flowmeter with solids content calculation feature Power 6 20 to 30VDC Power consumption 20W max 7 85 to 264VAC 50 60Hz Temperature Input 0...

Страница 11: ...1 Density corrected for temperature and pressure 9 Other than above special Communication Capability 0 No 1 Yes Finish 1 Munsell N1 5 Table 5 4 EL4331 Product Code Explanation Item Product Code Descr...

Страница 12: ...ving between menu items or changing numerical values 6 1 3 Error Messages When an erratic condition arises an error message automatically appears on the display NOTE The information represented by err...

Страница 13: ...plays it If it exceeds preset high or low limit its default fallback value is shown Total Mass Flowrate TOTAL COUNT Displays mass flow corrected for meter error Total Mass Flow of Solid Content TOTAL...

Страница 14: ...re pressure and density currently coming in and displays it Specific Weight SPECIFIC WEIGHT Calculates specific weight based on the temperature pressure and density currently coming in and displays it...

Страница 15: ...Xs Da Db Dx Dc Dx2 Ta Tb tx Tc tx2 100 where Xs Solids proportion Da to Dc Ta to Tc Coefficients to determine Xs Instant flowrate of solids content EL4311 Xs E Qsr Qr kg h Qr a f 1 3600 kg h 100 100 w...

Страница 16: ...instrument operates with no fluid flow How to Check 1 Couple sources of simulated temperature and pressure signals 2 Using the shift keys select menu items and verify the information displayed NOTE Se...

Страница 17: ...ulty 2 Pressure transmitter is faulty 3 A fault in internal assembly Faulty meter error correction factor and or temperature correction factor 1 Temperature and pressure readings correct 1 A fault in...

Страница 18: ...2 OVER Analog pressure input 2 overflow 25 PRESS 2 UNDER Analog pressure input 2 underflow 26 DENSITY OVER Density input overflow 27 DENSITY UNDER Density input underflow 28 4mA SCALER 1 UNDER Analog...

Страница 19: ...Std Span 200 C 10mV C Range 50 to 150 C 5 V C Range 100 to 200 C Density 0 0000 to 6 0000g ml Com puting accuracy ULTRA mass MKII CN series Density before correction 0 001g ml Factory calibration acc...

Страница 20: ...cimal place Solids content proportion To the 2nd decimal place Error alarm Number of errors error messages Com puting range Temperature Pt 100 at 0 C Range 50 to 200 C Std span 70 C 4 to 20mADC or 1 t...

Страница 21: ...ted Pressure To the 4th decimal place when MPa is selected Molecular weight To the 3rd decimal place when g mol is selected Specific weight To the 3rd decimal place Error alarm Number of errors error...

Страница 22: ...th decimal place when MPa is selected Molecular weight To the 3rd decimal place when g mol is selected Specific weight To the 3rd decimal place Error alarm Number of errors error messages Com puting r...

Страница 23: ...r Multi plexer Press Input Ckt analog Temp Input Ckt analog Temp Input Ckt Pt Analog Output Circuit Pulse Output Circuit 1 Pulse Output Circuit 2 Pulse Output Circuit 3 I O Board CPU Board Communicati...

Страница 24: ...E 886 2 E All specifications are subject to change without notice for improvement 2017 01 Revised 2008 08 Released E 886 2 E 1...

Отзывы: