4. Symbology Parameters
This section describes user configurable parameters
which are pertaining to barcode symbologies.
4.1 Code39
•
Standard / Full ASCII Code 39
: User can
choose to read either Standard Code 39 or Full
ASCII Code 39 by configuring this parameter.
•
Start/Stop Transmission
: This parameter
specifies whether the start/stop characters of
Code 39 are included in the data being
transmitted.
•
Checksum Verification
: This parameter
specifies whether the scanner will perform
checksum verification when decoding
barcodes. If the checksum is incorrect, the
barcode will not be read.
•
Checksum Transmission
: This parameter
specifies whether the checksum character are
included in the data being transmitted.
4.2 Italy / French Pharmacode
For Italy /French Pharmacode, there is always a
checksum character included in the barcode. So the
checksum verification is always performed when
decoding these symbologies. User though can choose
whether the checksum character is to be transmitted
or not. The start / stop transmission of this code
shares the same setting of Code 39.
•
Checksum Transmission
: This parameter
specifies whether the checksum character are
included in the data being transmitted.
4.3 Industrial / Interleave / Matrix 25
•
Start / Stop Selection
: This parameter
provides the readability of all 2 of 5
symbology variants. For example, flight tickets
actually use an Industrial 25 barcode but with
Interleave 25 start / stop. In order to read this
barcode, the
start / stop selection
parameter
of Industrial 25 should set to ‘
Interleave 25
.