background image

 

12

4.  Symbology Parameters 

This section describes user configurable parameters 
which are pertaining to barcode symbologies. 

4.1  Code39 

• 

Standard / Full ASCII Code 39

 : User can 

choose to read either Standard Code 39 or Full 
ASCII Code 39 by configuring this parameter. 

• 

Start/Stop Transmission

 : This parameter 

specifies whether the start/stop characters of 
Code 39 are included in the data being 
transmitted. 

• 

Checksum Verification

 : This parameter 

specifies whether the scanner will perform 
checksum verification when decoding 
barcodes. If the checksum is incorrect, the 
barcode will not be read. 

• 

Checksum Transmission

 : This parameter 

specifies whether the checksum character are 
included in the data being transmitted. 

4.2  Italy / French Pharmacode 

For Italy /French Pharmacode, there is always a 
checksum character included in the barcode. So the 
checksum verification is always performed when 
decoding these symbologies. User though can choose 
whether the checksum character is to be transmitted 
or not. The start / stop transmission of this code 
shares the same setting of Code 39. 

• 

Checksum Transmission

 : This parameter 

specifies whether the checksum character are 
included in the data being transmitted. 

4.3  Industrial / Interleave / Matrix 25 

• 

Start / Stop Selection

 : This parameter 

provides the readability of all 2 of 5 
symbology variants. For example, flight tickets 
actually use an Industrial 25 barcode but with 
Interleave 25 start / stop. In order to read this 
barcode, the 

start / stop selection

 parameter 

of Industrial 25 should set to ‘

Interleave 25

Содержание 1021 PLUS

Страница 1: ...s Manual 1067 1090 1021 CCD Scanner Document Number 6790 0116 Release Date Nov06 1998 1998 SYNTECH INFORMATION Co Ltd All rights reserved CipherLab is a registered trademark of SYNTECH INFORMATION Co...

Страница 2: ...radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whic...

Страница 3: ...7 3 1 4 Capital Lock Status 7 3 1 5 Alphabets Transmission 8 3 1 6 Digits Transmission 8 3 1 7 Inter Character Delay 8 3 2 RS232 Interface 9 3 2 1 Transmission Mode 9 3 2 2 Baud Rate Parity Data Bits...

Страница 4: ...s 21 6 6 Additional Fields 21 6 7 Field Transmission Sequence 21 6 8 End of Format Programming 22 6 9 Activate Data Editing Formats 22 6 10 Exclusive Data Editing 22 6 11 Programming Examples 22 7 Con...

Страница 5: ...er provides for easy installation and high product durability The scanner can not only fulfill the requirements needed today but also can suffice for long term usage The main functions and features pr...

Страница 6: ...configuration mode the scanner will normally beep twice when a setup barcode is read If the particular setup parameter needs more than one read the scanner will only issue a short beep to indicate th...

Страница 7: ...ng until the switch is triggered again Momentary Mode The scanner will be scanning as long as the switch is depressed Repeat Mode The scanner is always scanning just like Continuous Mode But now the s...

Страница 8: ...o Off Mode or Auto Power Off Mode This time out duration is specified in units of second The default time out duration is ten seconds 2 6 Reading Redundancy This parameter is used to specify the level...

Страница 9: ...h or without Addon Code 93 Code 128 EAN 128 MSI Plessey 2 8 Negative Barcodes The CCD scanner can be configured to read negative barcodes Normally barcodes are printed with the color of the bars darke...

Страница 10: ...ported keyboard types are listed below PCAT US French German Italian Swedish Norwegian UK Belgium Spanish and Portuguese KBD PCXT PS2 30 PS 55 IBM 5550 IBM 3477 TYPE Japanese KBD IBM 34XX 319X Memorex...

Страница 11: ...d Style Alphabets and perhaps Character Substitution setting when support to languages not available on the scanner is needed 3 1 4 Capital Lock Status In order to send alphabets with correct case the...

Страница 12: ...can transmit digits by using the alphanumeric key or by using the numeric key pad The Num Lock status of the keyboard should be ON if numeric key pad option is selected Keyboard 3 1 7 Inter Character...

Страница 13: ...inal The interface cable for dual port operation always has two connectors one of them is a male connector and the other one is a female connector Under dual port operation user can select whether dat...

Страница 14: ...is inserted between transmitting every character The longer the delay time configured the slower the transmission speed will be The inter character delay is zero by default 3 3 Wand Emulation The Wan...

Страница 15: ...11 User can then select the desired baud rate parity and data bits to be used in this output interface The Inter Character Delay and Capital Lock Status settings can also be configured...

Страница 16: ...are included in the data being transmitted 4 2 Italy French Pharmacode For Italy French Pharmacode there is always a checksum character included in the barcode So the checksum verification is always p...

Страница 17: ...length Code length parameters can be configured in two ways Fixed Code Length or Max Min code length If the fixed code length is selected up to 2 fixed lengths can be specified And if max min code le...

Страница 18: ...t scanning UPCA or EAN13 into UPCE system number 1 barcodes Convert to UPCA If this parameter is enabled the UPCE read will be expanded into UPCA and the following processing will follow the parameter...

Страница 19: ...um Transmission If this parameter is enabled the checksum character will be included in the data being transmitted 4 9 MSI Checksum Verification Three kinds of checksum calculations can be implemented...

Страница 20: ...he max length and the min length must be specified and the scanner will only accept those codes with lengths fall between max min length specified 4 10 Plessey Convert to UK Plessey If this parameter...

Страница 21: ...configured on a character base That is a specific character is to be substituted by an another character The character substitution is performed on every occurrence of the characters specified in thes...

Страница 22: ...25 D I Z I S Matrix 25 E G G G S Codabar F N X N F Code 93 I L L L G Code 128 H K K K C UPCE S E C E E EAN8 P B B FF E EAN13 M A A F E MSI V V D P M Plessey W W E Q P UPCA M A A F E 5 4 Length Code Tw...

Страница 23: ...field dividing rules additional fields and field transmission sequence parameters can be configured After all the desired parameters are configured the End of Format Programming label must be read to...

Страница 24: ...configured is both zero the scanner will not perform this length qualification Matching String and its Location User can specify a particular character string up to four characters that must appear in...

Страница 25: ...hough has the option of discarding this terminating string Field Length The field dividing rule can be configured by simply specifying the field length The scanner will assign the next specified numbe...

Страница 26: ...eter is enabled all data read by the scanner must be processed by the editing format If the data is not eligible for all enabled editing formats the scanner will not accept the reading and the data wi...

Страница 27: ...AB character and finally the quantity Total Number of Fields 3 Field 1 Divide field by field length set the field length to 6 Field 2 Divide field by field terminating string Set terminating string to...

Страница 28: ...every even page of the Configuration Manual 7 2 Default All the parameters of the scanner will return to their default values by reading the Default label The scanner will beep twice when the Default...

Страница 29: ...cter delay prefix postfix code etc For these kinds of parameters the label of the parameter to be configured must be read first And then the labels comprising the numeric value or character string are...

Страница 30: ...n only be specified for some particular parameters when keyboard interface is used These parameters are Prefix Code Postfix Code Code ID and Additional Fields of Editing Formats The available key type...

Страница 31: ...owing hexadecimal digits are the scan code value of the character being programmed Add Shift The Shift key will be sent together with the character programmed Add Control L The left Control key will b...

Страница 32: ...r a string parameter will decrease if these character specifications are used 7 5 Exit Configuration Mode Both the Update and the Exit Setup without Changes labels will exit the scanner from configura...

Отзывы: