Owner & Safety Manual
D.864.000.V4
En-3
OUTLAND FIREBOWL
®
OWNER & SAFETY MANUAL
2
CONNECTION:
1.
Be sure the cylinder valve and appliance valves are “off”.
2. Place full LP gas cylinder on tank stabilizer ring.
3. Center the nipple in the cylinder valve and hold in place.
4. Using the other hand, turn the hand wheel clockwise until
there is a positive stop. Do not use tools.
5. Hand tighten only. When making the connection,
hold the regulator in a straight line with the cylinder valve, so
as not to cross thread the connection.
6. Leak test the connection. See section named “LEAK TEST”.
LEAK TEST:
1.
DO NOT USE OR PERMIT SOURCES OF IGNITION
IN THE AREA WHILE DOING THE LEAK TEST.
THIS INCLUDES SMOKING.
2.
Leak testing should be done once per year or whenever the
LP gas cylinder or any other gas system part is taken apart,
serviced or replaced, whichever is more frequent.
3. Ensure all gas system coupling joints are tight
and properly attached.
4. Prepare a leak testing solution of half liquid detergent
and half water.
5. Apply the solution to the LP gas delivery system at points as
shown in illustration indicated on page 3.
6.
If parts of the fitting begin to produce bubbles, spray liquid, or
if you smell liquid propane gas, immediately close the valve on
the tank.
7.
Wait 5 minutes for any gas to dissipate.
8.
After waiting for 5 minutes, the leak(s) must be stopped by
tightening the loose joints, if possible, or by replacing the
faulty parts(s) with the part(s) recommended by the appliance
manufacturer.
WARNING:
Ensure that the appliance is kept at a minimum distance of
0.91 m / 36 in from the gas cylinder.
LP
Cylinder
Tank Ring
1. Firebowl
Valve Coupling
Appliance
Tank Ring
Minimum
0.91 m / 36 in
LEAK TEST: Apply the solution to the LP gas delivery
system at points:
1. Firebowl Valve Coupling
2. Gas Hose Regulator
3. Cylinder Valve Coupling
Caution:
Trip Hazard!
2. Gas Hose
Regulator
Heat Sensitive
Hand Wheel
Cylinder
Shut Off
Valve
Check Valve
Nipple with
Flow Limiting Device
3. Cylinder Valve
Coupling