6
Set-Up
Liquid Propane
Your Outdoor Plus fire pit is built with
a tank enclosure, but is not provided
with a propane tank. You will need to
provide one. The enclosure will ac-
commodate a 2 lb propane tank.
Use these specification for purchas-
ing your propane tank:
Specifications
The 2 lb propane gas supply cylinder
is constructed and marked in accor-
dance with the specifications for propane gas cylinders as required by
the U.S. Department of Transportation (DOT) or the CAN/CSA B339, Cyl-
inders, Spheres and Tubes for the Transportation of Dangerous Goods.
Manifold Pressure: For plumbed-in liquid propane installation, use a
regulator.
Supply Pressure: Maximum line pressure for plumbed-in propane is 14”
W.C psi (3.5 kPa). Minimum line pressure for propane is 11” W.C.
Pressure Regulator: The unit must be used with the supplied gas pressure
regulator and hose assembly. The regulator will control and maintain a
uniform gas pressure in the manifold. The burner orifice has been sized
for the gas pressure delivered by the regulator. Replacement pressure
regulator and hose assemblies must be those specified in this manual.
Cylinder Specification: Any propane gas supply cylinder used with this
fire pit must be approximately 12 inches in diameter and 18 inches high.
The maximum fuel capacity is 20 lbs. of propane, or 5 gallons. Full cyl-
inder weight should be approximately 38 lbs. (43.7 lbs. nominal water
capacity.) Always use the cylinder dust cap on the cylinder valve outlet
during transport and when the cylinder is not connected to the fire pit.
The 20 lb propane gas cylinder used must include a collar to protect the
cylinder valve.