Figure 8.5 Exterior View
Fire Risk.
Finish all edges and fronts to clearances
and speci
fi
cations listed in manual.
• Black metal columns may be covered with
non-combustible material only.
• Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials only up to specified
clearances on top, front and side edges.
• Seal joints between the
fi
nished wall and appliance top
and sides using only a 300º
F minimum sealant.
May install non-combustible materials to cover gap be-
tween facing material and appliance (see Figure 8.5).
Fire Risk.
Water Intrusion Risk.
Hood is required.
• Flashing and non-combustible sheathing must be
installed before facing materials.
• Facing must be non-combustible and seal tight to
fi
replace front.
Risk of Fire
• Non-combustible clearances must be
maintained.
• Sheetrock, wood or other combustibles must NOT
be used as sheathing or facing in the non-
combustible zone.
• See
Sections 3 & 8
for proper clearances.
• See
Section 1
for combustible/non-
combustible de
fi
nitions.
2-3/4 IN.
10-7/8 in.
HOOD
NON-COMBUSTIBLE
SHEATHING
6 in.
MAX.
NON-COMBUSTIBLE
FACING
THERE MUST BE NO GAP
BETWEEN BRICK LEDGE,
FACING MATERIAL AND
APPLIANCE FRONT
6 in. MAXMUM PROJECTION
FROM FACE OF FIREPLACE
BRICK LEDGE
NON-COMBUSTIBLE
SHEATHING (SUPPLIED)
COMBUSTIBLE
SHEATHING
HOUSEWRAP
REQUIRED
FLASHING
(SUPPLIED)
HOUSE
WRAP
EXHAUST
FRESH AIR INTAKE
WARNING
WARNING
WARNING
NOTICE:
If using an acid-based wash to clean
fi
nishing
material, cover the face of the
fi
replace with plastic sheet
to protect the paint. Remove plastic before operation of
fi
replace.