10
Outdoor Lifestyles by Hearth & Home Technologies • Twilight-II-B Installation Manual • 2108-970 Rev. H • 5/14
Figure 3.3 Clearances to Combustibles
H
K
G
F
J
I
Note:
Framing dimensions assume use of
1/2 inch thick wall covering materials on
exterior of framing only, and NO sheetrock
on interior of framing.
From top of hood to
ceiling (interior) or
overhang (exterior).
Figure 3.4 Exterior View - Finishing Material Clearances
MINIMUM CLEARANCES
Vinyl
Non-vinyl
A
36 in.
12 in.
B
64-5/16 in.
35-5/16 in.
OVERHANG
A
A
B
SIDING
SIDING
SIDING
FINISHING MATERIALS
A
INTERIOR
FRAMING
EXTERIOR
FRAMING
E
D
C
A
B
NOTICE:
Install appliance on hard metal or wood surfaces
extending full width and depth.
DO NOT
install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire!
Do not install appliance against
vapor barriers or exposed insulation. Prevent contact with
sagging or loose insulation.
• Locate and install appliance to all clearance speci
fi
cations
in manual.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with
fi
replace.
• Failure to maintain airspace may cause overheating and
a
fi
re.
• Reference Figure 3.2, Figure 3.3, and Figure 3.4 for
clearance speci
fi
cations.
CLEARANCES TO COMBUSTIBLES:
A
B
C
D
E
F
G
H
I
J
K
Exterior
Rough
Opening
(Height)
Interior
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Framing
for non-
combustible
material
Clearance
to Ceiling
(INTERIOR)
Clearance to Overhang
(EXTERIOR)
Combustible
Floor
Combustible
Flooring
Standoff
Height
Interior
Standoff
Height
Exterior
Sides of
Appliance
Non-Vinyl
Vinyl
Inches
47-5/8
41-1/4
23
44
46-1/8
35-3/4
35-5/16
64-5/16
0
0
3-3/8
9-1/2
1/2
mm
1210
1048
584
1118
1172
908
897
1634
0
0
86
241
13
Note:
Verify that tabs on insulation bracket are in an upright
position.
Finishing Material Clearances