Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17
W
ARNING
Do not fill spaces around firebox with
insulation or other materials. This could
cause a fire.
W
ARNING
Unit framing is to be rectangular front to
back. Failure to do so will cause fire and
damage to property.
Face should be covered a minimum of
3/4” around entire face.
3/4”
Figure 3.2
B. Clearance to Combustibles
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a
carpet, tile or other combustible material
other than wood flooring. If installed on
carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or
noncombustible material panel extending
full width and depth of the appliance.
W
ARNING
68” (1727 mm)
Minimum
Ceiling
12” (305 mm)
Max. Depth
2
1
/
2
” (64 mm)
Max Depth
6” (152 mm)
Min. From
Opening
12” (305 mm) Min.
From Opening
6”
(152 mm)
Min.
5-3/4” (146 mm)
Min. to Combustibles
Figure 3.3 - Ceiling and Sidewall Clearances for Both Sides of
Fireplace