16 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Courtyard Installation Manual • 4608-901 Rev. A • 02/18
A. Wiring Requirements
WARNING! Risk of Shock or Explosion! DO
NOT wire 110-120 Vac. to the valve or to the
appliance wall switch. Incorrect wiring will damage
controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes,
or in the absence of local code, with
National
Electric Code ANSI/NFPA 70-latest edition
or
the
Canadian Electric Code CSA C22.1.
Total Electrical Requirements: 110-120Vac.,
60Hz., less than 12 Amperes.
• The junction box comes wired with a 6’ section
of electrical cable that can be wired to an
external unswitched 110-120Vac junction box.
This is required for proper operation of the
appliance.
• A 110-120Vac circuit for this appliance must be
protected with ground-fault circuit-interrupter
protection in compliance with the applicable
electrical codes.
• Low voltage and 110-120 Vac voltage cannot
be shared within the same wall box.
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior
to disconnection when servicing controls. Wiring
errors could cause improper and dangerous
operation. Verify proper operation after servicing.
B. IntelliFire Ignition System Wiring
Wire the 6' harness from the appliance to 110-120
Vac for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO
NOT wire IPI controlled appliance junction box to
a switched circuit. Incorrect wiring will override IPI
safety lockout.
THIS APPLIANCE IS SUPPLIED STANDARD
WITH:
• IntelliFire control valve (3V)
• Wall switch control – Operates unit On/Off
• Conductor wall switch wire
• Pre-wired internal junction box with 6’ cable
C. Installing the Electrical
Note:
The Courtyard is supplied with a pre-wired
junction box with a 6' cable that can be installed
on the left or right side of the appliance for gas
and electrical connections.
The internal junction box comes pre-wired and is
only requires the 6' section to be wired externally
of the unit.
See 3.1 and 3.2.
5
Electrical Information
Note:
The Courtyard appliance
MUST
be connected to
a GFCI (Ground Fault Circuit Interrupt) protected circuit
breaker.
Valve
Control
Module
Junction
Box
Injector
Burner
Tube
Cover Screws
Figure 5.1.
Component Location