www.desatech.com
123748-01A
6
aSSEMBLy
Continued
5. Temporarily connect hose and regulator
to manifold. Connect hose and regulator
to a 20 lb. propane cylinder.
dO NOT LIGhT hEATER!
Open propane cylinder valve. Leak test
burner assembly and manifold connection
using a noncorrosive leak detection fluid.
DO NOT USE FLAME. See
Checking for
Leaks
, page 7. When there is no sign of
a leak, turn off propane/LP cylinder valve
and disconnect regulator from propane/
LP gas cylinder. Slowly loosen connection
between manifold and hose and regulator
assembly. Propane gas left in hose will
escape.
6. Slide pole cover over pole (see Figure 7).
7. Carefully insert manifold through pole.
Attach pole to burner assembly with 3
bolts.
8. Insert manifold into top of base assembly.
Align holes in bottom of pole with mount-
ing holes on base. Secure pole to base
with 3 screws and washers.
Figure 6 - Attaching Manifold to Burner
Assembly
Figure 8 - Inserting Manifold Through Pole
Figure 7 - Assembled Pole, Pole Cover
and Base
Figure 9 - Attaching Pole to Base
Manifold
Burner
Assembly
Pole Cover
Pole
4. Thread manifold to bottom of burner
assembly. Tighten with wrenches (see