14 |
P a g e
Gas Connection
1.
With proper orifice installed for the
application (#43 for propane, #31 for
natural gas) and metal flex hose attached,
set burner in base.
2.
Connect the incoming gas hose (black
rubber hose from propane tank or incoming
natural gas line) to the valve and tighten
securely with two wrenches. Repeat with
flexible metal gas line from the valve to the
underside of burner. It is not recommended
to use Teflon tape or pipe dope on the
connection to the valve with flare fittings.
LPG installations use the hose and regulator
provided with the burner.
For Natural Gas hookup information and
any other info not listed here consult your
Crystal Fire owner’s manual.
Read and understand your Crystal Fire burner owner’s manual
before beginning burner hookups or using the device.
Metal flex hose to burner