background image

12 

 

 

 

Before operating your fire table, ensure all gas connections are properly 

tightened and thoroughly leak checked. Refer to the Crystal Fire Manual for 

information on proper leak checking and other critical safety information.

 

 

 

With the valve on the fire pit in the OFF 
position, open the valve on the propane tank 
or natural gas supply.  
 

 

Double check to make sure there are no gas 
leaks at the regulator or inlet side of the 
valve. If leak is detected, immediately shut off 
the gas supply and wait 5 minutes to allow 
gas to dissipate. Fix any leaks before 
proceeding. 
 
 

 

Press the sparker button and hold, look and 
listen for spark between electrode and 
grounding rod.  
 

 

While depressing the sparker, open the valve. 

 

3. Turn valve to ON 

2. Look/listen for spark 

1. Depress sparker 

 

If burner does not light after 10 seconds, 
close the valve and wait 5 minutes to allow 
gas to dissipate before attempting ignition 
again. 

 

Refer to the Crystal Fire Manual included with your burner for 

more detailed information on operation, maintenance, and safety 

of your burner. 

 

Operating Instructions

 

11. 

Содержание BC-20-AB

Страница 1: ...1 Beacon Fire Table Installation Instructions for Beacon Fire Table BC 20 AB BC 20 BG BC 20 MNB BC 20 WO BD 20 BG BD 20 MNB BD 20 WO...

Страница 2: ...ia Installation 11 Burner Cover Installation 11 Operating Instructions 12 Required Tools Utility Knife To cut and remove packaging 2 Open Ended Wrenches To secure gas connections Leather Gloves To pro...

Страница 3: ...d Noche Supercast Top White Onyx Supercast Top Adhesive Foam Pads X4 20 Crystal Fire Burner CF 20 Refer to Crystal Fire Manual for items included with crystal fire burners Included with Your Fire Tabl...

Страница 4: ...s Attachment bracket for aluminum frame X4 for granite top installations only Self Drilling Screws X12 20 Crystal Fire Burner CF 20 Included with Your Fire Table Granite Top BC 20 AB BC 20 BG BD 20 BG...

Страница 5: ...n Assembly Instructions Locate CF SPARKER inside of crystal fire burner box Remove CF SPARKER cap and hex nut Insert AAA battery not included with end out Install CF SPARKER into control panel as show...

Страница 6: ...on top of the base Supercast Top Placement 4 a Refer to this step for grey table bases with Supercast Tops BC 20 WO BD 20 WO Refer to this step for brown table bases with Supercast Tops BC 20 MNB BD 2...

Страница 7: ...chment bracket to the top of each leg oriented so the open channel is towards the center of the base Lower the Aluminum Frame onto the base align the frame with the 4 mounting brackets Secure frame in...

Страница 8: ...tions For propane tank installations install included propane hose and regulator to the control panel as shown below Use two wrenches to ensure a gas tight connection For hard piped installations conn...

Страница 9: ...ystal Fire Burner Owner s Manual included with burner for orifice sizing information Ensure flex line is securely tightened to the orifice Use two wrenches as shown One wrench on the flex line and one...

Страница 10: ...sure no hoses or wires are contacting the bottom of the burner Push the access drawer with propane tank back into the base as shown below Drawer Operation and Propane Tank Installation 8 NOTE Over tim...

Страница 11: ...ce DO NOT OPERATE CRYSTAL FIRE BURNER WITHOUT INCLUDED GLASS BEADS OR OTHER APPROVED FIRE MEDIA Carefully lay cover on top of burner Make sure burner is cool before attempting to place cover DO NOT OP...

Страница 12: ...ak is detected immediately shut off the gas supply and wait 5 minutes to allow gas to dissipate Fix any leaks before proceeding Press the sparker button and hold look and listen for spark between elec...

Страница 13: ...ing lighting and operating instructions safety information and proper tightening of connections with two wrenches DO NOT ATTEMPT TO INSTALL CRYSTAL FIRE BURNER WITHOUT FIRST CONSULTING THE CRYSTAL FIR...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...visit http www outdoorrooms com warranty form to register your product 14400 Southcross Drive West Suite 100 Burnsville MN 55306 Toll Free 1 866 303 4028 Sales OutdoorRooms com Thank you for purchasi...

Отзывы: