Страница 2: ......

Страница 3: ...LY AGREED TO IN WRITING OUTBACK POWER SYSTEMS a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL B...

Страница 4: ...ir warranties The customer must return the component s to OutBack securely packaged properly addressed and shipping paid We recommend insuring your package when shipping Packages that are not securely packaged can sustain additional damage not covered by the warranty or can void warranty repairs There is no allowance or reimbursement for an installer s or user s labor or travel time required to di...

Страница 5: ...3 of the National Electric Code ANSI NFPA 70 is the responsibility of the installer For most installations the negative battery conductor should be bonded to the grounding system at one and only one point in the DC system All installations should comply with all national and local codes and ordinances The equipment ground on FLEXware 250 is marked with this symbol FLEXware is designed for indoor m...

Страница 6: ...ansformers multiple DC shunts and other essential components required in higher kW systems FLEXware 250 Parts List The FLEXware 250 consists of an aluminum enclosure which can be used for either the AC or DC side of an FX Series Inverter Charger Each FLEXware 250 includes Installed ground bus bar Breaker Guard for DC installations Hardware Kits for mounting to an FX and for securing AC and DC brea...

Страница 7: ... a vertical forward facing position and cannot face downward or upward Otherwise the breakers can malfunction FLEXware 250 mounted as a DC enclosure shown with cover plate The FLEXware 250 also accommodates a shelf or flat surface mounting as long as no breaker slots are facing downward or upward FLEXware 250 mounted as an AC enclosure ...

Страница 8: ... AC side Unthreaded standoffs for attaching to FX Unthreaded standoffs insert into the AC or DC end of the FX Inverter Charger s top casting mounting holes Figure 3 FLEXware 250 top view DC side Bottom 2 knockout Ground Bus Bar ...

Страница 9: ...t knockouts DC breaker slots 2 conduit knockout Figure 4 FLEXware 250 DC side AC breaker slots Bypass Slide Plate mounting holes 2 conduit knockout AC receptacle knockoff off grid systems only Unthreaded standoffs 3 4 counduit knockout 1 conduit knockout Figure 5 FLEXware 250 AC side ...

Страница 10: ...hese screws to install the FLEXware 250 on the DC side of the FX unthreaded standoffs insert into screw holes Figure 6 FLEXware 250 AC and DC chassis mounting locations AC side screw holes DC side screw holes Figure 7 Side view of FLEXware 250 fitting onto AC side of an FX Series Inverter Charger Unthreaded standoff Screw hole ...

Страница 11: ... upper and lower casing halves on whichever side AC or DC you first install the FLEXware 250 Insert the unthreaded standoffs into the holes on the FX and then insert two M5 X 25mm screws included with the FLEXware 250 into the standoffs and tighten After all wiring has been completed install the DCC and securing with four M5 X 12mm screws included with the DCC Install each FLEXware 250 top cover p...

Страница 12: ...10 The dashed lines represent the FLEXware 250 enclosure This drawing shows two units one for an AC application and one for a DC application Figure 9 FLEXware 250 DC Wiring Diagram ...

Страница 13: ...11 ...

Страница 14: ..._____ Installer Address ________________________ Installer City State Zip ____________________ Installer E mail _ _________________________ System System Install Commission Date ___________ Please circle type of application Off Grid Grid Interactive AC Coupled Backup Mobile Enclosure Model Number s _______________ OB Kit Model Number ____________________ Sold by _______________________________ Pur...

Страница 15: ...13 ...

Страница 16: ...utbackpower com 900 0088 01 00 REV A European Sales Office C Castelló 17 08830 Sant Boi de Llobregat BARCELONA España 34 93 654 9568 Corporate Office 19009 62nd Avenue NE Arlington WA 98223 USA 360 435 6030 ...