18
PRESS THREE TIMES:
The CHARGER CONTROL screen appears. This allows the
•
operation of the Inverter’s battery charger to be preset for
an available AC source.
CHARGER CONTROL
currently:
AUTO
OFF AUTO ON OK
<OFF> disables all charger functions in the Inverter.
<AUTO> enables automatic battery charging, silent, and “re-float” when an AC input source is connected.
<ON> also recharges the batteries, but eventually remains in the “float” charging stage (and eliminates
silent mode) until the AC input is disconnected.
<OK> returns to the point in the menu system where you entered the AC INPUT CONTROL menu cycle.
PRESS FOUR TIMES:
CHARGER MODE CONTROL
global charger mode
BULK EQ OK
The CHARGER MODE CONTROL screen appears, allowing the
•
MATE to issue system (global) recharging commands.
BULK CONTROL
START STOP OK
BULK CONTROL
bulk charge started
OK MAIN
BULK CONTROL
bulk charge stopped
OK MAIN
Pressing <
•
BULK> brings up the BULK
CONTROL screen. This allows the user to
manually start or stop a bulk charge cycle
by pressing the <START> or <STOP> soft
keys respectively.
NOTE
: The charger’s operation is independent of the inverting function. With the inverting function OFF,
the charger can be set to come on when AC is available, but the inverting function will stay off with AC
disconnected.
EQUALIZE CONTROL
eq enabled
START STOP OK
NOTE
: EQ is not normally used with the OBX-IC2024S-120/60 Inverter.
Pressing <EQ> on the CHARGER MODE CONTROL screen brings up
the EQUALIZE CONTROL screen
Once the <
•
START> or <STOP>
soft keys are pressed, the BULK
CONTROL screen shows the
status. The user can press <OK>
to return to the CHARGER MODE
CONTROL screen, or <MAIN> to