MALFUNCTION 

MALFUNCTION ANALYSIS

Please check below items before asking for servicing. If the malfunction still cannot be eliminated,  
please contact a qualified person. 

Errors

Possible Causes

Failed startup

There is no power supply.
The breaker opens owing to electrical leakage.
Voltage is too low.

Stop after a short while of operation

The air inlet/outlet of the indoor/outdoor unit is clogged.

Poor cooling effect

The air filter screen is too dirty or clogged.
There are too much heat sources or people in the room.
The door or window is open.
There are obstacles at the air inlet/outlet.
The set temperature is too high.

Poor heating effect

The air filter screen is too dirty or clogged.
The door or window is not closed fully.
The set temperature is too low.

Uncontrollable controller

If the remote controller crashes even if the batteries have been 
replaced, please open the back cover of it and press the button 
“ACL” to let it back to the normal condition.
Is the remoter controller in the signal receiving range? 
Or is it blocked by obstacles?
For the duct type unit, operate the remote controller pointing 
at the wired controller.

Содержание SMD09KCHVS-I

Страница 1: ...er s manual carefully before operating the unit and keep it for future reference DUCTABLE UNIT MULTIZONE HEAT PUMP Owner s Manual INVERTER 9 000 to 24 000 BTU hr Models SMD09KCHVS I SMD12KCHVS I SMD18...

Страница 2: ...of air supply duct 11 Drawings of the air supply outlet and returned air inlet 12 Installation of return air duct 12 Installation of condensate pipe 13 Design of drain pipe 14 Installation of drain pi...

Страница 3: ...on that if not avoided could result in serious injury or death Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related inf...

Страница 4: ...ion or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This product must not be di...

Страница 5: ...on must be performed by a qualified person Otherwise it may cause personal injury or damage Must follow the electric safety regulations when installing the unit According to the local safety regulatio...

Страница 6: ...he wire yourself After the electrical installation take an electric leakage test WARNING Location If you need to relocate the appliance to another place only a qualified person can perform the work Ot...

Страница 7: ...4 30 13 16 6 1 8 7 7 8 25 SMD18KCHVS I 37 1 16 19 5 16 33 15 16 32 5 16 35 7 16 24 1 4 38 11 16 6 1 8 7 7 8 25 SMD24KCHVS I 45 19 5 16 41 13 16 40 3 16 43 5 16 24 1 4 46 9 16 6 1 8 7 7 8 25 Models mm...

Страница 8: ...set or radio to avoid image interference and noise even if the clearance distance is kept noise may be produced due to strong electromagnetic wave Indoor unit This unit should be recessed mounted in...

Страница 9: ...nishing installation The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube The appliance shall be installed in accordance with national wi...

Страница 10: ...ns of indoor unit section for the distance between holes and to opposite drawing for installation of the expansion bolts Step 2 Install the hangers on the indoor unit Step 3 Install the indoor unit on...

Страница 11: ...een 7 Main Air Supply Duct 8 Air Supply Outlet B Round air supply duct No Name 1 Return Air Duct 2 Canvas Duct 3 Return Air Louver 4 Hanger 5 Air Supply Outlet 6 Transition Duct 7 Air Supply Duct 8 Di...

Страница 12: ...CHVS I 6 1 8 156 26 1 16 662 22 13 16 580 6 3 8 162 SMD12KCHVS I 6 1 8 156 26 1 16 662 22 13 16 580 6 3 8 162 SMD18KCHVS I 6 1 8 156 33 15 16 862 30 11 16 780 6 3 8 162 SMD24KCHVS I 6 1 8 156 41 13 16...

Страница 13: ...nage of the condensate water The joints of the condensate pipe should be insulated to prevent condensing as shown on opposite image There is a condensate outlet on both left and right sides of the uni...

Страница 14: ...also recommended to use thicker pipe for such a purpose INSTALLATION OF DRAIN PIPE The diameter of the drain pipe should be larger than or equal to that of the refrigerant pipe PVC pipe outer diameter...

Страница 15: ...m 39 3 8 1000 mm 33 1 2 850 mm 11 13 16 300 mm 5 15 16 150 mm Hanger bracket Clamp accessory Drain hose accessory Lift pipe Ceiling Notes The inclination height of the drain hose should be within 3 i...

Страница 16: ...any joints of the indoor unit by force otherwise the capillary pipe or other pipes may crack which would result in leakage The refrigerant pipe should be supported by brackets Do not let the unit wit...

Страница 17: ...d of the wire about 1 in 25 mm off with a wire striper Loosen the screw off on the wiring board of the air conditioning unit Shape with the pliers at the end of the wire to a circle matching with the...

Страница 18: ...ity for the damage or abnormal running of the unit WIRING OF THE POWER CORD SINGLE PHASE CAUTION The power supply for each indoor unit must be uniform Remove the electric box cover of the indoor unit...

Страница 19: ...CHVS I 208 230V 60HZ 0 406 75 575 AWG18X4 SMD12KCHVS I 208 230V 60HZ 0 348 65 865 AWG18X4 SMD18KCHVS I 208 230V 60HZ 0 428 80 1080 AWG18X4 SMD24KCHVS I 208 230V 60HZ 0 588 110 1610 AWG18X4 Note The se...

Страница 20: ...here are too much heat sources or people in the room The door or window is open There are obstacles at the air inlet outlet The set temperature is too high Poor heating effect The air filter screen is...

Страница 21: ...energized Check whether mounting bracket is damaged or corroded Note If there is something abnormal please consult the after sales serviceman Maintenance after seasonal use Let the air conditioning u...

Страница 22: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Отзывы: