Ouellet FCD09KCHVS-I Скачать руководство пользователя страница 4

4

USER NOTICES

•  The total capacity of the indoor units running at the same time cannot exceed 150% of the outdoor 

unit capacity. Otherwise, the cooling or heating effect of each indoor unit will be poor. 

•  To ensure a successful startup, switch the main power on 8 hours before powering on the unit.

•  After receiving the “Off” signal, each indoor unit will continue to operate for 20 to 70 seconds to use the 

remaining cool or warm air in the air exchanger while preparing for the next operation. This is normal.

•  When the operating mode of the indoor unit is in conflict with that of the outside unit, a malfunction 

light will blink for 5 seconds on the indoor unit display or on the controller to warn the user. Then the 
indoor unit will stop. Change the operating mode of the indoor unit to match that of the outdoor unit 
or with a compatible mode. COOL mode is compatible with DRY mode and FAN mode is compatible 
with all operating modes. 

•  If the supply power fails when the unit is running, the indoor unit will send the “start” signal to the 

outdoor unit three minutes after power recovery.

•  This appliance is not intended for use by people (including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they are under the supervision or 
instruction concerning use of the appliance by a person responsible for their safety. Children should  
be supervised to ensure that they do not play with the appliance.

•  This product must not be disposed together with the domestic waste. This product has to be disposed 

at an authorized place for recycling of electrical and electronic appliances.

PRECAUTIONS

 

WARNING

Operation and Maintenance

•  This appliance can be used by people (including children of 8 years old and above) with reduced phy- 

sical, sensory or mental capabilities, or lack of experience and knowledge, as long as they are under  
the supervision or instruction concerning use of the appliance by a person responsible for their safety.

•  Children shall not play with the appliance.

•  Cleaning and user maintenance shall not be made by children.

•  Do not connect to multi-purpose socket. Otherwise, it may cause fire hazard.

•  Disconnect power supply when cleaning. Otherwise, it may cause electric shock.

•  If the power supply wire is damaged, it must be replaced by a qualified person in order to avoid  

a hazard.

•  Do not wash with water to avoid electric shock.

•  Do not spray water on indoor unit. It may cause electric shock or malfunction.

•  After removing the filter, do not touch fins to avoid injury.

•  Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.

•  Do not operate this unit with wet hands.

•  Maintenance must be performed by qualified person. Otherwise, it may cause personal injury  

or damage.

Содержание FCD09KCHVS-I

Страница 1: ...manual carefully before operating the unit and keep it for future reference FLOOR OR CEILING UNIT MULTIZONE HEAT PUMP Owner s Manual INVERTER 9 000 to 24 000 BTU hr Models FCD09KCHVS I FCD12KCHVS I F...

Страница 2: ...Special functions 13 Replacing batteries in remote control 13 Preparation before installation 14 Outline dimensions of indoor unit 14 Required installation clearance distances diagram 14 Selection of...

Страница 3: ...on that if not avoided could result in serious injury or death Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related inf...

Страница 4: ...pervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This product must not...

Страница 5: ...must be performed by a quali ed person Otherwise it may cause personal injury or damage Must follow the electric safety regulations when installing the unit According to the local safety regulations u...

Страница 6: ...ctric leakage test WARNING Location If you need to relocate the appliance to another place only a quali ed person can perform the work Otherwise it may cause personal injury or damage Select a locatio...

Страница 7: ...ct may be di erent from below graphics please refer to actual product for reference purposes Indoor unit Remote Control Air outlet Guide louver Front panel Air lter puri er in air inlet grille Connect...

Страница 8: ...rol to direct sunlight or to very hot places Never let any liquid ow into the wireless remote control If the remote control does not operate normally please take out the batteries and reinsert them af...

Страница 9: ...e AUTO CLEAN function 12 TEMP Switch temperature displaying type 13 TURBO Set turbo fan speed 14 SLEEP Lowering or raising the temperature gradual ly during the night 15 LIGHT Lighted display 1 2 2 3...

Страница 10: ...this sequence Automatic AUTO low medium high NOTE On AUTO speed the device will choose ideal speed according to room temperature and set temperature In DRY mode dehumidi cation fan always goes at low...

Страница 11: ...in this manual 8 CLOCK button Press this button to set time Icon on remote control will blink Within the next 5 seconds press button or to set time With every push on the button or time increases or d...

Страница 12: ...will conti nue to operate for 2 minutes in order to dry the indoor unit to prevent mold growth This function is available only in COOL or DRY mode When you press this button icon appears on the screen...

Страница 13: ...to gradually increase room temperature in COOL mode and to lower it in HEAT mode You will then save energy without a ecting your sleep This function is settled over an 8 hour period After this period...

Страница 14: ...ALLATION OUTLINE DIMENSIONS OF INDOOR UNIT 1220 mm 700 mm 225 mm 1158 mm 280 mm REQUIRED INSTALLATION CLEARANCE DISTANCES DIAGRAM 600 mm 1000 mm 300 mm 600 mm 1500 mm 300 mm 600 mm 600 mm 1500 mm 200...

Страница 15: ...ast 3 3 ft 1 m away from the TV set or radio to avoid image interference and noise even if the clearance distance is kept noise may be produced due to strong electromagnetic wave Indoor unit There sho...

Страница 16: ...nishing installation The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube The appliance shall be installed in accordance with national wi...

Страница 17: ...mm or 70 mm depending on selected outlet pipe Allow space around the pipe for an easier indoor unit pipe connection In order to drain e ciently slant the piping hole on the wall slightly downward to t...

Страница 18: ...ponge gray Drain Hose NOTES The diameter of the drain pipe should be larger than or equal to that of the refrigerant pipe PVC pipe outer diameter 1 in 25 mm wall thickness 1 16 in 1 5 mm The drain pip...

Страница 19: ...ver pull any joints of the indoor unit by force otherwise the capillary pipe or other pipes may crack which would result in leakage The refrigerant pipe should be supported by brackets Do not let the...

Страница 20: ...a quali ed person If the length of power connection wire is insu cient please contact your dealer for a new one Do not extend the wire by yourself A circuit break must be installed in the line The ai...

Страница 21: ...removing the brackets from the indoor unit Set the suspension bolts Use W3 8 or M10 size suspension bolts NOTE Adjust the distance from the unit to the ceiling beforehand Fix the hanger brackets to th...

Страница 22: ...TES Adjust the height by rotating the nut with a spanner Insert the spanner into the hanger bracket through the interspace Only the speci ed accessories and parts for installation work can be used Stu...

Страница 23: ...low setting Adjust fan setting with the remote control Is the SWING setting ok Adjust SWING setting with the remote control Are the doors and windows closed fully Close doors and windows Is the unit...

Страница 24: ...tion are in good condition Check if air lter is clean and well installed To ensure a successful startup switch the main power on 8 hours before powering on the unit Maintenance after seasonal use Let...

Страница 25: ...should be increased generally once every two weeks If it is necessary to change the lter purchase a new one at your local dealer Do not use re or hair dryer to dry the lter to avoid deformation or re...

Страница 26: ...rature is lower than 16 C the appliance will not work in COOL cooling mode 3 Operating pressure test In COOL or HEAT mode set the temperature to the maximum set point 30 C or 86 F Press the TURBO butt...

Страница 27: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Страница 28: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Отзывы: