OPERATION OF REMOTE CONTROL

1. ON/OFF button

Pushing this button allows to turn on or off the device. When turning off the unit, the SLEEP function will 
be canceled but the pre-set time remains.

2. +/- button

Push " + " or " - " button to decrease or increase temperature by one degree at a time.

Temperature range is from 16 °C to 30 °C (61 °F to 86 °F).

Maintain " + " or " - " button pushed for 2 seconds in order to change rapidly temperature. Once settings 
done, release button and temperature will be modified accordingly (temperature can’t be settled in  
AUTO mode).

While adjusting TIMER ON, TIMER OFF or CLOCK, push " + " or " - " button to set the time. (Please see 
section CLOCK, TIMER ON, TIMER OFF buttons for more details.)

3. FAN button

Push this button to select the fan speed along this sequence: 

Automatic (AUTO), low ( 

 ), medium ( 

 ), high ( 

 ).

 

NOTE:

 

•  On AUTO speed, the device will choose ideal speed according to room temperature and set  

temperature.

•  In DRY mode (dehumidification), fan always goes at low speed.

4. MODE button

Push this button in order to select operating mode of your choice:

 

 

AUTO mode:  
When you select automatic mode, the device automatically selects the appropriate function to maintain 
temperature between 20 °C and 25 °C (68 °F to 77 °F). In this mode, temperature can’t be changed or 
displayed on remote control. When turned on the first time, it works in AUTO mode by default. 

COOL mode:  
When you select COOL mode, the appliance is cooling the room. Press " + " or " - " to set temperature. 

DRY mode:  
When you select DRY mode, the appliance is in dehumidifying mode and works at its lowest speed. In this 
mode, the fan speed can’t be changed.

FAN mode:  
When you select FAN mode, only the fan is operating. There is no heating, nor cooling in this mode.

Содержание FCD09KCHVS-I

Страница 1: ...manual carefully before operating the unit and keep it for future reference FLOOR OR CEILING UNIT MULTIZONE HEAT PUMP Owner s Manual INVERTER 9 000 to 24 000 BTU hr Models FCD09KCHVS I FCD12KCHVS I F...

Страница 2: ...Special functions 13 Replacing batteries in remote control 13 Preparation before installation 14 Outline dimensions of indoor unit 14 Required installation clearance distances diagram 14 Selection of...

Страница 3: ...on that if not avoided could result in serious injury or death Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related inf...

Страница 4: ...pervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This product must not...

Страница 5: ...must be performed by a quali ed person Otherwise it may cause personal injury or damage Must follow the electric safety regulations when installing the unit According to the local safety regulations u...

Страница 6: ...ctric leakage test WARNING Location If you need to relocate the appliance to another place only a quali ed person can perform the work Otherwise it may cause personal injury or damage Select a locatio...

Страница 7: ...ct may be di erent from below graphics please refer to actual product for reference purposes Indoor unit Remote Control Air outlet Guide louver Front panel Air lter puri er in air inlet grille Connect...

Страница 8: ...rol to direct sunlight or to very hot places Never let any liquid ow into the wireless remote control If the remote control does not operate normally please take out the batteries and reinsert them af...

Страница 9: ...e AUTO CLEAN function 12 TEMP Switch temperature displaying type 13 TURBO Set turbo fan speed 14 SLEEP Lowering or raising the temperature gradual ly during the night 15 LIGHT Lighted display 1 2 2 3...

Страница 10: ...this sequence Automatic AUTO low medium high NOTE On AUTO speed the device will choose ideal speed according to room temperature and set temperature In DRY mode dehumidi cation fan always goes at low...

Страница 11: ...in this manual 8 CLOCK button Press this button to set time Icon on remote control will blink Within the next 5 seconds press button or to set time With every push on the button or time increases or d...

Страница 12: ...will conti nue to operate for 2 minutes in order to dry the indoor unit to prevent mold growth This function is available only in COOL or DRY mode When you press this button icon appears on the screen...

Страница 13: ...to gradually increase room temperature in COOL mode and to lower it in HEAT mode You will then save energy without a ecting your sleep This function is settled over an 8 hour period After this period...

Страница 14: ...ALLATION OUTLINE DIMENSIONS OF INDOOR UNIT 1220 mm 700 mm 225 mm 1158 mm 280 mm REQUIRED INSTALLATION CLEARANCE DISTANCES DIAGRAM 600 mm 1000 mm 300 mm 600 mm 1500 mm 300 mm 600 mm 600 mm 1500 mm 200...

Страница 15: ...ast 3 3 ft 1 m away from the TV set or radio to avoid image interference and noise even if the clearance distance is kept noise may be produced due to strong electromagnetic wave Indoor unit There sho...

Страница 16: ...nishing installation The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube The appliance shall be installed in accordance with national wi...

Страница 17: ...mm or 70 mm depending on selected outlet pipe Allow space around the pipe for an easier indoor unit pipe connection In order to drain e ciently slant the piping hole on the wall slightly downward to t...

Страница 18: ...ponge gray Drain Hose NOTES The diameter of the drain pipe should be larger than or equal to that of the refrigerant pipe PVC pipe outer diameter 1 in 25 mm wall thickness 1 16 in 1 5 mm The drain pip...

Страница 19: ...ver pull any joints of the indoor unit by force otherwise the capillary pipe or other pipes may crack which would result in leakage The refrigerant pipe should be supported by brackets Do not let the...

Страница 20: ...a quali ed person If the length of power connection wire is insu cient please contact your dealer for a new one Do not extend the wire by yourself A circuit break must be installed in the line The ai...

Страница 21: ...removing the brackets from the indoor unit Set the suspension bolts Use W3 8 or M10 size suspension bolts NOTE Adjust the distance from the unit to the ceiling beforehand Fix the hanger brackets to th...

Страница 22: ...TES Adjust the height by rotating the nut with a spanner Insert the spanner into the hanger bracket through the interspace Only the speci ed accessories and parts for installation work can be used Stu...

Страница 23: ...low setting Adjust fan setting with the remote control Is the SWING setting ok Adjust SWING setting with the remote control Are the doors and windows closed fully Close doors and windows Is the unit...

Страница 24: ...tion are in good condition Check if air lter is clean and well installed To ensure a successful startup switch the main power on 8 hours before powering on the unit Maintenance after seasonal use Let...

Страница 25: ...should be increased generally once every two weeks If it is necessary to change the lter purchase a new one at your local dealer Do not use re or hair dryer to dry the lter to avoid deformation or re...

Страница 26: ...rature is lower than 16 C the appliance will not work in COOL cooling mode 3 Operating pressure test In COOL or HEAT mode set the temperature to the maximum set point 30 C or 86 F Press the TURBO butt...