Please read this owner’s manual carefully
before operating the unit and keep it for future reference.
CONSOLE
MULTIZONE HEAT PUMP
Owner’s Manual
INVERTER
9 000 to 12 000 BTU/hr
Models:
CMD09KCHVS-ICMD12KCHVS-I
Страница 1: ...se read this owner s manual carefully before operating the unit and keep it for future reference CONSOLE MULTIZONE HEAT PUMP Owner s Manual INVERTER 9 000 to 12 000 BTU hr Models CMD09KCHVS I CMD12KCH...
Страница 2: ...cial functions 14 Replacement of batteries in remote control 15 Preparation before installation 17 Indoor unit installation drawing 17 Required installation clearance distances diagram 17 Selection of...
Страница 3: ...on that if not avoided could result in serious injury or death Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related inf...
Страница 4: ...pervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance This product must not...
Страница 5: ...must be performed by a quali ed person Otherwise it may cause personal injury or damage Must follow the electric safety regulations when installing the unit According to the local safety regulations u...
Страница 6: ...or unit and outdoor unit should be connected by a quali ed person If the length of power connection wire is insu cient please contact the dealer for a new one Do not extend the wire yourself After the...
Страница 7: ...r lter Flap horizontal blade Air outlet Louvres vertical blades inside the air outlet Air inlet Opening the Front Panel Room temperature sensor Air outlet selection button This setting blows air from...
Страница 8: ...may be di erent from below graphics please refer to actual product for reference purposes COOL mode LED indicator LED display Indoor unit ON OFF button Receiving window DRY mode LED indicator HEAT mo...
Страница 9: ...UIET mode 11 CLOCK Set up the clock 12 TIMER ON OFF Set starting and ending time 13 TURBO Set turbo fan speed 14 LIGHT Lighted display 15 X FAN Activation of the AUTO CLEAN function 1 2 3 4 5 6 9 7 11...
Страница 10: ...ws to turn on or o the device Working indicator on display of indoor unit will be green when device is turned on and will be red when it s turned o 2 button Push or button to decrease or increase temp...
Страница 11: ...Automatic AUTO low medium low medium medium high high NOTES On AUTO speed the device will choose ideal speed according to room temperature and set tempera ture In DRY mode dehumidi cation fan always g...
Страница 12: ...it will increase of 2 C 3 F or 4 F In HEAT mode One hour after activation the temperature setting will decrease of 1 C 1 F or 2 F After 2 hours it will decrease of 2 C 3 F or 4 F Sleep 2 In this mode...
Страница 13: ...previous 2 steps until the desired temperature is set for all 4 periods 9 TEMP button When pushing this button you can choose the temperature you wish to see on the indoor unit display set temperature...
Страница 14: ...on 2 Press the or button in order to set the ending time 3 Press again TIMER OFF to con rm time Icon OFF appears and remote control shows current time To cancel this function press the TIMER ON and or...
Страница 15: ...lay in C or F When device is turned o OFF press simultaneously on and MODE buttons to switch from C or F FREEZE PROTECT mode During winter FREEZE PROTECT mode allows to maintain room temperature at 8...
Страница 16: ...he remote control and receiving window should not be more than 26 25 ft 8 m and there should be no obstacle between them The remote control should be placed 3 3 ft 1 m away from TV or Audio sets The s...
Страница 17: ...mounted in three di erent ways Exposed Floor lnstallation Wall Installation Half conceated Mounting plate Grid eld supply Molding Concealed REQUIRED INSTALLATION CLEARANCE DISTANCES DIAGRAM 59 150 cm...
Страница 18: ...ast 3 3 ft 1 m away from the TV set or radio to avoid image interference and noise even if the clearance distance is kept noise may be produced due to strong electromagnetic wave Indoor unit There sho...
Страница 19: ...nishing installation The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube The appliance shall be installed in accordance with national wi...
Страница 20: ...d then point out the screw xing holes on the wall 160 mm 30 mm 30 mm 170 mm 220 mm 120 mm 644 mm 700 mm 200 mm 200 mm 600 mm 570 mm 120 mm 220 mm Schematic drawing of hooks Installation template Drill...
Страница 21: ...nit pipe connection In order to drain e ciently slant the piping hole on the wall slightly downward to the outdoor side with a gradient of 5 to 10 NOTES Pay attention to dust and take relevant safety...
Страница 22: ...in pan Seal Drain hose Drain pan Seal Connect drain pipe to supplied drain hose and bind the joint with tape Add insulating pipe around the indoor drain hose in order to prevent condensation NOTES Pla...
Страница 23: ...n nut Tighten the union nut with torque wrench Adjust the torque force by referring to the following table Wrap the indoor pipe and joint of connection pipe with insulating pipe and then wrap it with...
Страница 24: ...ensor securing plate and remove the front metal plate cover Remove the wire retainer connect the power connection wire to the wiring terminal according to the color tighten the screw and then x the po...
Страница 25: ...n hose Liquid pipe Reserve a certain length of drain hose and power cord for installation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose...
Страница 26: ...pipes in the wall pipe and then make them pass through the wall hole Secure the unit using 6 screws for installation Do not forget to secure the wall behind 200 mm Casing Floor Installation Wall Inst...
Страница 27: ...low setting Adjust fan setting with the remote control Is the SWING setting ok Adjust SWING setting with the remote control Are the doors and windows closed fully Close doors and windows Is the unit...
Страница 28: ...seasonal use Check if the air inlet outlet of the indoor unit is clogged Check if circuit breaker and connection are in good condition Check if air lter is clean and well installed To ensure a success...
Страница 29: ...tened with water below 45 C Let it dry in a shady and cool place Step 4 Reinstall the front panel Insert the front panel into the grooves of the unit 3 places Attach the string to the right inner side...
Страница 30: ...or re hazard Step 1 Open the front panel Slide the two stoppers on the left and right sides inward until you hear a click Step 2 Remove the air lter Press the claws on the right and left of the air lt...
Страница 31: ...e Since the puri ers are made out of paper do not wring out the lter when removing water from it Step 5 Install the air puri ers and air lter Install the air puri ers on the air lter Install the air l...
Страница 32: ...rature is lower than 16 C the appliance will not work in COOL cooling mode 3 Operating pressure test In COOL or HEAT mode set the temperature to the maximum set point 30 C or 86 F Press the TURBO butt...
Страница 33: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...
Страница 34: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...