STEP 6 

– ATTACH SCREEN (NOT USED WITH MIXER) 

 

  

     

    

 

 

FRACTIONAL SERIES MIXER ASSEMBLY 

STEP 1 

– PLACE POWER UNIT BETWEEN BRACKETS 

STEP 2 

– POSITION UNIT & TIGHTEN BOLTS 

                

 

FRACTIONAL SERIES MIXER PITCH ADJUSTMENT 

LOOSEN BOLTS, POSITION & TIGHTEN 

Max. Torque 8N-m / 70in-lb 

 

  

 

ALIGN FLATS ON 

HOUSING RING 

TO BRACKETS

 

POSITION CABLE 

CONNECTION 

FACING FLOAT

 

     USE 10mm WRENCH 

Max. Torque 

8N-m / 70in-lb 

ALWAYS FASTEN 

CABLE TO BRACKET 

AS SHOWN 

PREVIOUSLY

 

LOOSEN 4 

BOLTS 

(2 EACH SIDE) 

FLOAT BRACKET 

HOLES FOR MIXER

 

FASTEN 

SCREEN TO 

LIP

 

PLACE CABLE 

BETWEEN FLOAT 

& SCREEN 

(TIE TO FLOAT)

 

USE SCREEN TO PREVENT PUMP CHAMBER 

CLOGGING DUE TO LARGE DEBRIS 

(GEMINI & HIGH VOLUME LESS PRONE TO CLOGGING) 

 

FASTEN SCREEN (8) PLACES EVENLY SPACED 

USE DRIVER OR PRE-DRILL 2.5mm (3/32”) HOLES

 

WHEN NOT USING SCREEN REPLACE SCREWS INTO HOLES 

ALWAYS PLUG OR SEAL UNUSED HOLES IN FLOAT 

OTTERBINE BAREBO INC.

 

Page 6

 

75-0009 Rev 01 50Hz Fractional Series

www.otterbine.com 

  1-800-AER8TER

Содержание Fractional Series

Страница 1: ...Otterbine Barebo Inc Fractional Series 50Hz Installation Manual Manual PN 75 0009 Rev 01 ...

Страница 2: ... water in which Otterbine Aerators or Fountains are installed make sure they are PHYSICALLY disconnected from their electrical power sources Aerators located in or near garden ponds and similar locations must be equipped with Ground Fault Circuit Interrupter The permissible temperature range for this equipment is 12oC to 40oC 10oF to 104oF If the power cord is damaged it must be replaced by a spec...

Страница 3: ...ctrical shock may occur The standard Power Control Center includes a fiberglass NEMA 4X or 3R enclosure with twenty four hour timer and personnel GFCI protection Fractional Series 50Hz Electrical Specifications HP Volts Phase Max Amps Maximum 12AWG Cable Length meters 1 2 230 1 2 8 183 A Feeder 1 Proper feeder circuit protection in accordance with all applicable local and national codes must be pr...

Страница 4: ...4 N m 30 in lb Maximum E PCC Timer Operation TRIPPER PINS TIME OF DAY 1 Push in towards center all tripper pins on the timer dial 2 Pull out the tripper pins on the dial that are between the times you want the unit to operate When the dial rotates to a tripper pin that is in it will turn off 3 Turn the outer dial clockwise to align the time of day to the stationary arrow positioned at 2 o clock 4 ...

Страница 5: ...LE UNDER FLOAT INSIDE SCREEN WHEN USED ALIGN FLATS ON HOUSING RING TO BRACKETS USE 10mm SOCKET Max Torque 8N m 70in lb TRIM EXCESS CABLE TIE USE 10mm SOCKET w EXTENSION Max Torque 8N m 70in lb FLOAT BRACKET LOWER HOLE SET FOR HIGH VOLUME ALL OTHER SPRAY PATTERNS USE UPPER HOLE SET SNAP COLORED LENSE ONTO LEGS OPTIONAL SNAP FIXTURE INTO POCKET OTTERBINE BAREBO INC www otterbine com 1 800 AER8TER 75...

Страница 6: ...m 70in lb ALWAYS FASTEN CABLE TO BRACKET AS SHOWN PREVIOUSLY LOOSEN 4 BOLTS 2 EACH SIDE FLOAT BRACKET HOLES FOR MIXER FASTEN SCREEN TO LIP PLACE CABLE BETWEEN FLOAT SCREEN TIE TO FLOAT USE SCREEN TO PREVENT PUMP CHAMBER CLOGGING DUE TO LARGE DEBRIS GEMINI HIGH VOLUME LESS PRONE TO CLOGGING FASTEN SCREEN 8 PLACES EVENLY SPACED USE DRIVER OR PRE DRILL 2 5mm 3 32 HOLES WHEN NOT USING SCREEN REPLACE S...

Страница 7: ...peratures are expected below 0 C 32 F For longer unit life store the unit indoors at temperatures above 0 C 32 F Operating Depth is 0 4m 16in Clean debris from screen and unit intake as necessary Inspect and clean the throat and nozzle components as required Annually clean and inspect the unit and cables for physical damage MIXER TIE THREE 3 MOORING LINES TO FLOAT AS SHOWN BELOW MOORING LINES NOT ...

Страница 8: ...FRACTIONAL SERIES PARTS LIST EXPLODED VIEW OTTERBINE BAREBO INC Page 8 75 0009 Rev 01 50Hz Fractional Series www otterbine com 1 800 AER8TER ...

Страница 9: ...PATTERN COMPONENT ASSEMBLY MIXER HIGH VOLUME GEMINI PHOENIX ROCKET UNIT DIMENSIONS OTTERBINE BAREBO INC www otterbine com 1 800 AER8TER 75 0009 Rev 01 50Hz Fractional Series Page 9 ...

Страница 10: ...INTENTIONALLY BLANK ...

Страница 11: ...r serviced by anyone other than BAREBO a service facility authorized by BAREBO to render such service or by an authorized BAREBO dealer and the serial number of the OTTERBINE product must not have been removed or altered and d The OTTERBINE product must not have been subjected to lightning strikes and other Acts of God vandalism freezing in accident misuse or abuse and must have been installed in ...

Страница 12: ...R FURTHER INFORMATION OR INSTRUCTIONS ON OTTERBINE PRODUCTS VISIT OUR WEBSITE www otterbine com Otterbine Barebo Inc 3840 Main Rd East Emmaus PA 18049 U S A 1 800 AER8TER 610 965 6018 FAX 610 965 6050 E mail aeration otterbine com ...

Отзывы: