ELECTRICAL INSTALLATION 

ALL ELECTRICAL WORK MUST BE PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN 

AND CONFORM WITH ALL APPLICABLE ELECTRICAL SAFETY CODES 

Tous

 

travaux électriques doivent être

 

effectués par un électricien

 

professionnel qualifié

 

et conforme à

 

tous les codes applicables sécurité électrique 

 

ALWAYS SWITCH OFF/DISCONNECT ALL EQUIPMENT IN THE WATER 

BEFORE SERVICING OR PERFORMING ANY MAINTENANCE 

Toujours éteindre l'équipement dans l'eau avant entretien ou de tout entretien 

 

CAUTION: GFCI PROTECTION REQUIRED 

If GFCI protection is not used, serious or FATAL electrical shock may occur 

ATTENTION: GFCI/RCD de protection est nécessaire 

Graves ou mortelles choc électrique peut se produire s'il n'est pas utilisé 

 

WARNING: RISK OF ELECTRIC SHOCK

 

The AirFlo 3 must be connected to a grounded, metallic, permanent wiring system 

Ground the compressor cabinet to the ground wire lead provided back to the service 

using a copper conductor at least the size of the circuit conductors supplying the cabinet. 

 

A. Branch Circuit Sizing (All valves must be in the open position before initial operation) 

1. The branch circuit feeding the Otterbine AirFlo 3 must be sized in accordance with all applicable codes and 

must 

provide GFCI (Ground Fault Circuit Interruption)/RCD (Residual Current Device)

 and short circuit protection. Refer to 

the nameplate label on the compressor cabinet above the electrical connection box for voltage and current requirements. 
The on/off switch provided with the AirFlo 3 

does not provide personal (GFCI / RCD) electrical shock protection.

 

 

B. Electrical Connection

 

1. The AirFlo 3 is not considered to be portable 
equipment and therefore 

flexible cord shall 

not be used

 to connect the cabinet to the 

power source. The electrical connection must 
be considered permanent and suitable for a 
NEMA 3R / IP34 environment. 
2. A 1/2" (22mm) trade size conduit entry is 
located at the bottom rear of the cabinet. If 
using PVC conduit it is important to provide an 
expansion coupling at the entry to the 
compressor cabinet. 
3. To make the conduit and wiring connections 
remove the electrical compartment cover 
shown on right. Pull the exposed field wiring 
connection leads inside the electrical 
compartment before making the conduit 
connection. 
4. When the field conduit and wiring is installed 
connect the field wiring to the wiring leads 
provided in the electrical compartment. Refer 
to electrical schematic provided with the 
Otterbine AirFlo 3 System. Replace the 
electrical compartment cover when complete. 

 

ELECTRICAL COMPARTMENT ON REAR OF COMPRESSOR CABINET 

 

 

Содержание AirFlo 3

Страница 1: ...Manual P PN 75 0109 R Rev 05 O A In Otterb AirFlo nstall bine B o 3 Di ation Bareb iffuse n Man bo In ed Ae nual nc eratio on...

Страница 2: ...registration card by mail to OTTERBINE within fifteen 15 days of receipt by the Purchaser at retail in order to avoid delays INSTALLATION TOOLS AND EQUIPMENT A Basic Installation Tools and Materials...

Страница 3: ...3 must be sized in accordance with all applicable codes and must provide GFCI Ground Fault Circuit Interruption RCD Residual Current Device and short circuit protection Refer to the nameplate label o...

Страница 4: ...old provided 2 Use the couplings and clamps provided in PN 12 0019 to couple each length of poly tubing to the heater hose protruding from the rear of the compressor cabinet as shown 3 Determine the d...

Страница 5: ...rope together be certain to pull the correct end with respect to the knot 5 Use the same method placing the Diffuser Base from a boat except two 2 ropes may be used on each end of the pad THREAD ROPE...

Страница 6: ...rror The valve supplying the Diffuser Manifold Base deepest in the water will remain fully open 5 IMPORTANT While balancing the diffused air patterns in the water attempt to maintain the lowest possib...

Страница 7: ...of once t remove the e twisting the t NO lubricatio Air Filte Ot RTS enter or the O bine com or or 1 610 965 SE DUCT MUST produit doiven ecommended s able through ressor Rebuil air to the com to the G...

Страница 8: ...Otterbine Barebo Inc 8 75 0109 AirFlo 3 www otterbine com 1 800 AER8TER COMPRESSOR CABINET COMPONENTS EXPLODED VIEWS...

Страница 9: ...Otterbine Barebo Inc 9 75 0109 AirFlo 3 www otterbine com 1 800 AER8TER DISC DIFFUSER BASE COMPONENTS PN 10 0301 SINGLE DISC DIFFUSER BASE PN 10 0302 DUAL DISC DIFFUSER BASE...

Страница 10: ...ne other than BAREBO a service facility authorized by BAREBO to render such service or by an authorized BAREBO dealer and the serial number of the OTTERBINE AirFlo 3 must not have been removed or alte...

Страница 11: ...Series Rocking Piston Oil less Pump To process any WARRANTY related activity on the AirFlo 3 Product Contact the nearest Otterbine Service Center or the Otterbine factory directly Visit www otterbine...

Страница 12: ...ter Works With Otterbine Otterbine Barebo Inc 3840 Main Rd East Emmaus PA 18049 U S A TOLL FREE 1 800 AER8TER 237 8837 PHONE 610 965 6018 FAX 610 965 6050 E mail aeration otterbine com www otterbine c...

Отзывы: