Safety | 2
SMP12 Smart Pyranometer | EN
9
2 Safety
WARNING
Failure to observe safety information and warnings may lead to injury and damage!
This chapter contains safety information and warnings. If the safety information and warnings are not heeded,
this may result in personal injury and material damage.
4
Carefully read through and observe the safety information and warnings.
4
Follow the instructions.
2.1 Read the operating manual
Failure to heed the operating manual may result in personal injury and material damage.
4
Read the operating manual carefully before using the product for the first time.
4
Pay attention to all safety information and warnings.
4
Keep the operating manual in a safe place.
2.2 Intended use
The SMP12 Smart Pyranometer can be used to measure and report the following data:
– Solar radiation
– Temperature of the sensor body
– Internal moisture
– Inclination angle from the horizontal
4
Use the SMP12 Smart Pyranometer only as described in the operating manual. Any other use is prohibited.
2.3 Target group and qualification
4
Only install and maintain the product if you have the corresponding qualifications.
4
Obtain training from OTT HydroMet if necessary.
2.4 Installation and maintenance in high places
When the product is installed and maintained in high places, special safety measures must be taken to avoid
personal injury.
4
Observe and follow the local safety regulations.
Содержание KIPP & ZONEN SMP12
Страница 3: ...US English 4 Deutsch 38 Fran ais 72 Italiano 106 Espa ol 140 174 SMP12 Smart Pyranometer 3...
Страница 177: ...1 SMP12 Smart Pyranometer ZH 177 IC ICES 003 B B ICES 003 B NMB 003 B 1 4 i 4 1 4 2 1 2...
Страница 178: ...1 178 SMP12 Smart Pyranometer ZH 1 5...
Страница 179: ...2 SMP12 Smart Pyranometer ZH 179 2 4 4 2 1 4 4 4 2 2 SMP12 4 SMP12 2 3 4 4 OTT HydroMet...
Страница 180: ...2 180 SMP12 Smart Pyranometer ZH 2 4 4 4 4 4 2 5 60 4 2 6 4 4 4 OTT HydroMet 4...
Страница 181: ...3 SMP12 Smart Pyranometer ZH 181 3 3 1 SMP12 Modbus RS 485 PLC...
Страница 189: ...4 SMP12 Smart Pyranometer ZH 189 4 5 2 Smart Explorer 4 Smart Explorer...
Страница 190: ...4 190 SMP12 Smart Pyranometer ZH 4 Setup 4 4 Update...
Страница 191: ...4 SMP12 Smart Pyranometer ZH 191 4 5 3 4 Setup Connection 4 Serial RTU protocol RS 485 4 COM Windows...
Страница 192: ...4 192 SMP12 Smart Pyranometer ZH 4 4 Confirm 4 5 4 4 Configuration...
Страница 195: ...4 SMP12 Smart Pyranometer ZH 195 4 5 5 4 Connections Single Instrument Use 4 Modbus Send Broadcast...
Страница 196: ...4 196 SMP12 Smart Pyranometer ZH 4 Start From Boot 4 1 Connections 4 Configuration 4 10...
Страница 197: ...5 SMP12 Smart Pyranometer ZH 197 5 5 1 5 1 1 5 5 10 h 10 x h 2 360 5 0 8 4 4 100 4...
Страница 198: ...5 198 SMP12 Smart Pyranometer ZH 5 1 2 8 mm 8 mm 65 mm 1 2 3 4 5 1 M5 80 mm 2 2 2 3 5 2 mm 2 4 2 5 2 4 4 2 3 mm 4 4 4...
Страница 199: ...5 SMP12 Smart Pyranometer ZH 199 4 50 4 4 4 4 4 4 4...
Страница 200: ...5 200 SMP12 Smart Pyranometer ZH 5 2 2 1 1 1 2 2 4 4 4 198 4 4 4 4...
Страница 201: ...5 SMP12 Smart Pyranometer ZH 201 5 3 R S D 1 2 5 3 4 H 1 2 3 4 5 5 D 2 S R2 H2 0 1 H 1 99 10 H 4 4 1 2...
Страница 202: ...5 202 SMP12 Smart Pyranometer ZH 5 4 0 1 1 2 3 6 4 5 1 2 3 4 5 6 4 198 4 201...
Страница 203: ...5 SMP12 Smart Pyranometer ZH 203 5 5 5 3 1 2 4 3 1 2 3 4 5...
Страница 204: ...5 204 SMP12 Smart Pyranometer ZH 4...
Страница 205: ...6 SMP12 Smart Pyranometer ZH 205 6 6 1 4 4 4 4 4 4 2 4 OTT HydroMet 6 2 OTT HydroMet 4 OTT HydroMet OTT HydroMet...
Страница 206: ...6 206 SMP12 Smart Pyranometer ZH 6 3 ElektroG 2012 19 EU OTT HydroMet 4 4 4...
Страница 207: ...7 SMP12 Smart Pyranometer ZH 207 7 7 1 4 4 12 24 V 4 4 4 4 OTT HydroMet...