Operating Instructions

Hydraulic Connections

1. 

It is necessary to vent the pump before using it.

 Loosen the oil fill knob by turning it counterclockwise. 

(The oil fill knob was installed and tightened to prevent the oil from leaking during shipment.)

2.  Clean all the areas around the fluid ports of the pump and cylinder.
3.  Inspect all threads and fittings for signs of wear or damage, and replace as needed.
4.  Clean all hose ends, couplers, and union ends.
5.  Remove the thread protector from the hydraulic fluid outlet. Connect the hose assembly to the hydraulic 

fluid outlet, and couple the hose to the cylinder.

Important: Seal external pipe connections with high-grade thread sealant.

Air Connections

1.  Remove the thread protector from the air inlet of the pump. Install a threaded fitting that is compatible with 

your air supply fitting.

2.  Connect shop air (with an air line filter installed) to the fitting, and regulate air supply pressure to between 

6 bar (90 psi) and 9 bar (140 psi). 

Priming the Pump

1.  Press the 

RELEASE

 end of the pedal while holding down the air intake valve with a flathead screwdriver. 

(The air intake valve is located directly under the pedal in the area marked 

PUMP

.)

2.  Allow the pump to cycle for approximately 15 seconds.
3.  Remove the screwdriver, and press the 

PUMP

 end of the pedal. If the cylinder extends and pressure builds, 

the pump has been successfully primed. If the pump does not respond, repeat steps 1–3, jogging the air 
intake valve while holding the pedal in the 

RELEASE

 position.

Operation

1.  To extend the cylinder, press the end of the pedal marked 

PUMP

.

2.  To hold the cylinder in position, release the pedal.
3.  To retract the cylinder, press the end of the pedal marked 

RELEASE

.

Содержание 2510A

Страница 1: ...echanism internal relief valve and 1606 CC 98 cu in of useable oil It pumps holds or releases a load with pedal control 1 of 4 Explanation of Safety Signal Words The safety signal word designates the degree or level of hazard seriousness DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation...

Страница 2: ... so tightly that the fluid flow within the hose is blocked or reduced Periodically inspect the hose for wear because any of these conditions can damage the hose and result in personal injury Do not use the hose to move attached equipment Stress can damage the hose and cause personal injury Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses must not come in conta...

Страница 3: ... Remove the thread protector from the air inlet of the pump Install a threaded fitting that is compatible with your air supply fitting 2 Connect shop air with an air line filter installed to the fitting and regulate air supply pressure to between 6 bar 90 psi and 9 bar 140 psi Priming the Pump 1 Press the RELEASE end of the pedal while holding down the air intake valve with a flathead screwdriver ...

Страница 4: ... retracted Add OTC approved hydraulic fluid 215 SSU 38 C 100 F if necessary 1 Retract the cylinder and disconnect the air supply 2 Clean the area around the filler vent plug Remove the filler vent plug 3 Insert a clean funnel with a filter Add OTC approved hydraulic fluid 215 SSU 38 C 100 F to a level 19 mm 3 4 inch from the filler vent plug 4 Replace the filler vent plug Draining and Flushing the...

Страница 5: ...pressure equal to or higher than relief valve setting 1 Air lubricator is set too rich if so equipped 1 Add hydraulic fluid to within 19 mm 3 4 inch of filler vent hole 2 Press RELEASE end of pedal while holding down air intake valve Allow pump to cycle for approx 15 seconds 3 Remove pump assembly from reservoir and clean intake filter 4 Use equipment with sufficient capacity for the job 1 Verify ...

Страница 6: ...6 62 67 68 61 86 60 59 58 57 56 55 54 53 52 51 50 48 47 46 45 49 42 44 41 40 43 39 10 9 8 7 6 5 38 1 2 3 4 11 12 13 14 15 16 17 18 19 20 21 22 29 27 26 25 24 28 30 32 31 37 36 35 34 33 10 23 Parts List Parts List Operating Instructions Form No 538016 Sheet 3 of 4 Back ...

Страница 7: ...Piston 27 3 Bolt j28 1 Shuttle Valve Seal j29 2 O ring j30 1 O ring 31 1 Rear Cover j32 1 O ring j33 1 O ring 34 1 Bolt 35 1 Fixing Base j36 2 O ring j37 1 O ring j38 1 O ring 39 1 Spring 40 1 Ball Seat 41 1 Steel Ball j42 1 O ring j43 1 Nylon Gasket Parts List continued 4 of 4 44 1 Release Valve 45 1 Ball Seat 46 1 Spring j47 1 O ring 48 1 Release Rod j49 4 O ring 50 1 Steel Ball 51 1 Spring 52 1...

Страница 8: ...aire hidráulica Número de modelo 2510A está en conformidad con los requerimientos aplicables de los siguientes documentos N de ref Título Edición Fecha N A N A N A Déclaration de conformité européenne Je déclare par la présente que l équipement désigné ici présent a été conçu conformément aux articles appropriés des spécifications susmentionnées et respecte les exigences de la ou des Directives Si...

Отзывы: