Sheet No.
Issue Date: Rev. C September 19, 2011
© SPX
Parts List & Operating Instructions
Form No. 538016
2 of 4
Operating Instructions
Hydraulic Connections
1.
It is necessary to vent the pump before using it.
Loosen the oil fill knob by turning it counterclockwise.
(The oil fill knob was installed and tightened to prevent the oil from leaking during shipment.)
2. Clean all the areas around the fluid ports of the pump and cylinder.
3. Inspect all threads and fittings for signs of wear or damage, and replace as needed.
4. Clean all hose ends, couplers, and union ends.
5. Remove the thread protector from the hydraulic fluid outlet. Connect the hose assembly to the hydraulic
fluid outlet, and couple the hose to the cylinder.
Important: Seal external pipe connections with high-grade thread sealant.
Air Connections
1. Remove the thread protector from the air inlet of the pump. Install a threaded fitting that is compatible with
your air supply fitting.
2. Connect shop air (with an air line filter installed) to the fitting, and regulate air supply pressure to between
6 bar (90 psi) and 9 bar (140 psi).
Priming the Pump
1. Press the
RELEASE
end of the pedal while holding down the air intake valve with a flathead screwdriver.
(The air intake valve is located directly under the pedal in the area marked
PUMP
.)
2. Allow the pump to cycle for approximately 15 seconds.
3. Remove the screwdriver, and press the
PUMP
end of the pedal. If the cylinder extends and pressure builds,
the pump has been successfully primed. If the pump does not respond, repeat steps 1–3, jogging the air
intake valve while holding the pedal in the
RELEASE
position.
Operation
1. To extend the cylinder, press the end of the pedal marked
PUMP
.
2. To hold the cylinder in position, release the pedal.
3. To retract the cylinder, press the end of the pedal marked
RELEASE
.