OTARI FS-96 Скачать руководство пользователя страница 1

Part No. OS1-132

February 2001

Ed.2 (TM)

Operation Manual

SETUP

ROUTING

SRC

AES  

EBU

96kHz

48kHz

44.

1kHz

32kHz

INT

EXT

INPUT

ADAT

SDIF

-2

TDIF

-1

OPTION

PRESET

ENTER

CANCEL

1

:

1

1234

POWER

FORMA

T & SAMPLE  RA

TE  CONVERTER

FS-

-96

Format & Sample Rate

Converter

Getting Started

Welcome to Otari FS-96  . . . . . . . . . . . . . . . . . . . . 4

Main Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Unpacking and Inspection . . . . . . . . . . . . . . . . . . . 5

Conventions within this Manual  . . . . . . . . . . . . . . 5

About Digital Audio Formats  . . . . . . . . . . . . . . . . . 5

Controls and Indicators

Front Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Rear Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Installation and Connection

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Power Supply and Grounding  . . . . . . . . . . . . . . . 8

Connecting Word Clock Signals  . . . . . . . . . . . . . 8

Connecting ADAT Optical Format Signals . . . . . 9

Connecting AES/EBU Format Signals  . . . . . . . . 9

Connecting SDIF-2 Format Signals  . . . . . . . . . . 9

Connecting TDIF-1 Format Signals  . . . . . . . . . . 9

Basic Operation

Powering Up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Basic Setup Instructions  . . . . . . . . . . . . . . . . . . . 10

Operations with LCD  . . . . . . . . . . . . . . . . . . . . . . 11

Modes of Operation  . . . . . . . . . . . . . . . . . . . . . . . 11

Resetting All Settings  . . . . . . . . . . . . . . . . . . . . . . 12

Using Key Lock Function . . . . . . . . . . . . . . . . . . . 12

Considering Signal Delay . . . . . . . . . . . . . . . . . . . 12

Mis-synchronization due to 

Additional Signal Connection . . . . . . . . . 12

Operating Memories

Using Preset Memories  . . . . . . . . . . . . . . . . . . . . 13

Recalling Preset Memories  . . . . . . . . . . . . . . . . . 13

Duplicating Preset Memories  . . . . . . . . . . . . . . . 14

Clearing Preset Memories  . . . . . . . . . . . . . . . . . . 14

Using PRESET Keys  . . . . . . . . . . . . . . . . . . . . . . . 15

Setup Mode

Operations in Setup Mode  . . . . . . . . . . . . . . . . . 16

Selecting Input Format  . . . . . . . . . . . . . . . . . . . . . 17

Selecting Reference Clock  . . . . . . . . . . . . . . . . . 18

Configuring Sample Rate Converter  . . . . . . . . 19

Changing Bit Resolution  . . . . . . . . . . . . . . . . . . . 20

Activating Dither Function  . . . . . . . . . . . . . . . . . . 20

Editing Status Data  . . . . . . . . . . . . . . . . . . . . . . . . 21

Adjusting Sync Timing  . . . . . . . . . . . . . . . . . . . . . 22

Adjusting LCD Contrast  . . . . . . . . . . . . . . . . . . . . 23

Routing Mode

Configuring Signal Routing  . . . . . . . . . . . . . . . . . 24

BI-DIRECTION MODE

Using Bi-Direction Mode  . . . . . . . . . . . . . . . . . . . 25

SPECIFICATIONS

FS-96 Specifications . . . . . . . . . . . . . . . . . . . . . . . 26

TABLE OF CONTENTS

Содержание FS-96

Страница 1: ...t Signals 9 Connecting TDIF 1 Format Signals 9 Basic Operation Powering Up 10 Basic Setup Instructions 10 Operations with LCD 11 Modes of Operation 11 Resetting All Settings 12 Using Key Lock Function...

Страница 2: ...is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the...

Страница 3: ...to fit contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the polarized plug If this product is equipped with a three wire grounding type plug a plug having a...

Страница 4: ...o available and it can be sample rate converted to the same output format if needed Accurate Clock Generation Circuit The FS 96 is equipped with an accurate clock generation circuit for achieving sign...

Страница 5: ...s Alesis Lightpipe A dedicated optic fiber cable is used for connecting 8 channels of digital audio The FS 96 provides three systems of ADAT interfaces for handling a total of 24 channels SDIF Sony Di...

Страница 6: ...channels are connected to the same output channels 10 Source indicators AES EBU ADAT SDIF 2 TDIF 1 OPTION Display the selection of the input format If no signal is present or synchronization to the i...

Страница 7: ...requires a Word Clock signal for synchronization a SYNC connector BNC type is provided for each of input and output connector 22 WORD IN connector Used to connect an external Word Clock signal which i...

Страница 8: ...frequencies 50 60 Hz used all over the world CAUTION To prevent damage to the FS 96 and the connected equipment do not connect or disconnect the cables while the machines are turned on Grounding The F...

Страница 9: ...n connector input male output female for connecting a maximum of 24 channels of audio Note that the Word Clock signal needs to be connected via the BNC connector for synchronization Pin Assignment 1 3...

Страница 10: ...N Channel Grouping All digital formats above are grouped in 8 channel groups except for SDIF 2 which is grouped in a single 24 channel group on a 50 pin connector Group A 1 8 Group B 9 16 Group C 17 2...

Страница 11: ...24 channels of digital audio The input digital audio signals will be converted to all of the signal formats available on the FS 96 When the FS 96 is in Normal mode all advanced functions are availabl...

Страница 12: ...all connectors are disconnected and then re connected the phase level synchronization of the input signals will be lost In this case the following screen appears on the LCD to alert the operator sinc...

Страница 13: ...nfiguration modes will be stored into the preset memories which are currently used When changing the operation parameters confirm that the desired memory numbers are displayed on the initial screen Se...

Страница 14: ...ING MEM 1 ROUTING MEM 0 ROUTING COPY 0 1 SETTING COPY 0 1 SETTING MEM 0 ROUTING MEM 0 ENTER SETTING MEM 0 ROUTING MEM 0 14 February 2001 Operating Memories Duplicating Preset Memories Clearing Preset...

Страница 15: ...e preset memory is recalled Storing into a Preset To store the current combination of the setting and routing memories hold the desired PRESET key down and press the ENTER key When the memory combinat...

Страница 16: ...tup mode and return to the initial screen Setup Mode Screens Setup mode consists of the following screens INPUT FORMAT screen p 17 used to select the input signal format This screen is also used when...

Страница 17: ...s are available in the INPUT FORMAT screen AES selects the AES EBU AES3 format ADAT selects the ADAT optical format SDIF selects the SDIF 2 format TDIF selects the TDIF 1 format BDIR used to place the...

Страница 18: ...sing YES After the desired option is selected press the ENTER key to change the status of the SRC USE TO SELECT YES NO 4 When INT is selected select a frequency of the signal and press the ENTER key W...

Страница 19: ...the devices there are slight fluctuations or jitters in the sample rates of digital audio signals The FS 96 is equipped with an accurate clock generation circuit and the input audio signals can be con...

Страница 20: ...ing Dither Function When the bit resolution is decreased the dither function can be activated for the audio data About Dither Function When the bit resolution is changed in a decreasing direction e g...

Страница 21: ...initial screen List of Status Data The following status data can be edited on the FS 96 AES EBU EMPH emphasis indicates the emphasis status of the AES EBU signals The following options are available T...

Страница 22: ...5 When the parameters are set to the desired values press the CANCEL key to return to the SYNC TIMING screen Or press the SETUP key to return to the initial screen Parameters in SYNC TIMING Screen Th...

Страница 23: ...een by pressing the upper lower Arrow keys 2 Press the ENTER key to select the screen The current contrast setting is displayed as a graph 3 Adjust the screen contrast with the right left Arrow keys a...

Страница 24: ...uration of the signal routing is made by assigning the input channels to the output channels When configuring the signal routing follow the instructions below 1 Select the desired routing memory numbe...

Страница 25: ...rters cannot be changed Even if the sample rate converter is activated it will be turned off automatically by entering into Bi Direction mode If the sample rate converter is turned on the following sc...

Страница 26: ...nce 75 both input output Connector BNC type x 2 input x 1 output x 1 Digital Audio Format ADAT AES EBU SDIF 2 TDIF 1 An option slot for the expansion module is provided on the rear panel Number of Cha...

Страница 27: ......

Страница 28: ...noga Park California 91304 U S A Phone 1 818 598 1200 Fax 1 818 594 7208 Otari Europe GmbH Rudolf Diesel Strasse 12 D 40670 Meerbusch Germany Phone 49 2159 50861 Fax 49 2159 1778 Otari Singapore Pte L...

Отзывы: