background image

FT410DB Series Installation & Operation Manual 

 

www.ot-systems.com

 

 

 

 

 

(3)  Installation 

3.1  General 

All  OT  Systems  products  are  thoroughly  inspected,  tested  and  securely  packaged  before 

delivery  to  ensure  a  stable,  intact  and  trouble-free  service.  Please  check  the  equipment  upon 

receipt for any visible damage which may have been caused during shipping. 

The  FT410DB  Series  standalone  units  (Fig.  3.1)  can  be  either  horizontally  or  vertically 

wall-mounted,  or  mounted  on  any  fixture.  The  Standalone  unit  works  with  an  external  power 

supply FT-PA/12V powered by local 110/220V power.   

The FT410DB Series card modules are housed inside the FT-C18 rack-mount chassis (Fig. 

3.2) with an included power supply unit. The whole chassis is powered by local 110/220V power. 

FT-C18 is a standard 19” (483mm) rack-mount chassis which occupies 4 rack units (177.8mm) in 

height.  Each  FT410DB  card module  occupies  one  slot  and  a  total  of  18  cards  can  be  housed 

inside the chassis. 

 

3.2  Standalone unit installation 

a) 

Mount the standalone unit onto a fixture, (either on the wall or on a flat surface) with four 

screws through the holes on the mounting frame to secure it in position.   

b) 

The provided power supply should also be mounted on the same fixture or in the proximity 

for  connection  of  the  supply  cables  to  the  unit,  provided  that  an  AC  power  supply  socket  is 

nearby for powering the adaptor. 

c) 

Connect  all  the  signal  inputs  and  outputs  at  the back  of  the  unit  with  appropriate  cables: 

fiber optic cable for optical link, BNC cables for video inputs/outputs (Tx/Rx), and UTP cable for 

data input/output (Tx/Rx).   

d) 

Once the unit is powered up, check that the red POWER LED on the unit is lit. If not, check 

the power supply cable connections between the unit and the power supply socket. 

e) 

With all the signals available at the input and output ports, check the status of LEDs located 

on the unit. With correct status of each LED, installation is now completed [for LEDs status, see 

Operational Guides

 on this manual’s section 

(5)

]. 

 

 

Fig. 3.1 

Standalone unit

 

Fig. 3.2 

FT-C18 chassis

 

Содержание FT410DB Series

Страница 1: ...Digital Fiber Optic Manufacturing Specialists Installation and Operation Manual FT410DB Series 10 bit Digital Series 4 ch Video with 1 Bi directional Data Fiber Optic Converter OT Systems Ltd 2009 Rev...

Страница 2: ...ivers FT410DB SSRSA FT410DB SSRLSA Multi Mode Transmitter FT410DB SMTSA Multi Mode Receiver FT410DB SMRSA Card Modules Single Mode Transmitters FT410DB SST FT410DB SSTL Single Mode Receivers FT410DB S...

Страница 3: ...tandalone unit installation 6 3 3 Card module installation 6 4 CABLE CONNECTIONS SETUP PROCEDURES 7 4 1 System cable connections 7 4 2 Data port assignment and pin connections 9 4 3 Dip switch setting...

Страница 4: ...Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing opera...

Страница 5: ...TDM technology is employed for digital transmission of forward video and data whereas optical Wavelength Division Multiplex WDM technology is employed for simultaneous reverse data transmission as wel...

Страница 6: ...nsmitter 1 Data Transceiver Standalone Unit FT410DB SMRSA Multi mode 4 Ch Video Receiver 1 Data Transceiver Standalone Unit Card Modules Single Mode FT410DB SST Single mode 4 Ch Video Transmitter 1 Da...

Страница 7: ...be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture either on the wall or on a flat surface with four screws through the holes on the mounting fra...

Страница 8: ...front and back panels of the card modules are lit If not check the power supply cable connections between the chassis and the power supply socket For failures of individual card s POWER LEDs check the...

Страница 9: ...tion Manual www ot systems com 8 Standalone Transmitter Card Module Receiver Fig 4 2 Standalone unit to Card Module connection diagram Card Module Transmitter Card Module Receiver Fig 4 3 Card Module...

Страница 10: ...gram Transmitter End Receiver End User s Equipment DATA PORT 7 PIN DATA PORT 7 PIN User s Equipment TX 1 IN 1 IN TX TX 2 IN 2 IN TX RX 3 OUT 3 OUT RX RX 4 OUT 4 OUT RX 5 N A 5 N A 6 N A 6 N A 7 N A 7...

Страница 11: ...6 OUT RX Sig COM 7 Sig COM 7 Sig COM Sig COM Fig 4 4 3 Connector Pin Assignments for RS232 data format at Data port 4 3 Dip switch setting procedures The only setup procedure is to select the appropr...

Страница 12: ...input and output lines terminated in the ONE Tx to ONE Rx configuration For RS485 2 4 wire communication the RS485 device can be disabled to stay in a Hi Z state It is very important that the data lin...

Страница 13: ...ge caused by lightning and other power surges as well as a connection to the surge suppresion devices in the product a screw terminal is provided on the Standalone cabinets Fig 4 7 It is highly recomm...

Страница 14: ...tical Connector for fiber cable connection VIDEO IN BNC Video Connectors for video signal inputs DATA 7 pin Screw Terminal Block for data signal 5 2 FT410DB Series Receiver LED Indicators Indicator Co...

Страница 15: ...in 1 typical Differential Phase 1o typical SNR 65dB DATA Channel Connector 1 7 pin Screw Terminal Direction Bi directional Duplex Electrical Format RS232 RS422 RS485 2 wire 4 wire Tri state Transmissi...

Страница 16: ...refer to the OT Systems Products Warranty Statement for details Access to the statement is available in our company website at www ot systems com 9 Contact Information OT Systems Ltd Hong Kong Unit 10...

Отзывы: