background image

FT410DB Series Installation & Operation Manual 

 

www.ot-systems.com

 

 

 

 

 

2.2  Models selection table   

T

y

p

e

 

M

o

d

e

 

Models

1

 

Descriptions 

Installation 

requirements 

Remarks 

S

ta

n

d

a

lo

n

e

 U

n

it

s

 

S

In

g

le

-M

o

d

e

 

FT410DB-SSTSA 

Single-mode 4-Ch. Video Transmitter 

& 1 Data Transceiver Standalone Unit 

Horizontally or 

vertically 

wall-mounted 

Standalone 

unit

 

FT-PA/12V 

external 

power 

supply is 

included for 

the 

Standalone 

unit

2

 

FT410DB-SSTLSA 

 

Single-mode Long-haul 4-Ch. Video 

Transmitter & 1 Data Transceiver 

Standalone Unit 

FT410DB-SSRSA 

Single-mode 4-Ch. Video Receiver & 

1 Data Transceiver Standalone Unit 

FT410DB-SSRLSA 

Single-mode Long-haul 4-Ch. Video   

Receiver & 1 Data Transceiver 

Standalone Unit 

M

u

lt

i-

M

o

d

e

 

FT410DB-SMTSA 

Multi-mode 4-Ch. Video Transmitter & 

1 Data Transceiver Standalone Unit 

FT410DB-SMRSA 

Multi-mode 4-Ch. Video Receiver & 1 

Data Transceiver Standalone Unit 

C

a

rd

 M

o

d

u

le

s

 

S

in

g

le

-M

o

d

e

 

FT410DB-SST 

Single-mode 4-Ch. Video Transmitter 

& 1 Data Transceiver Card Module 

Housed in 

FT-C18 

chassis

3

 

FT-C18 

chassis has 

to be 

ordered 

separately 

FT410DB-SSTL 

 

Single-mode Long-haul 4-Ch. Video   

Transmitter & 1 Data Transceiver 

Card Module 

FT410DB-SSR 

Single-mode 4-Ch. Video Receiver & 

1 Data Transceiver Card Module 

FT410DB-SSRL 

Single-mode Long-haul 4-Ch. Video   

Receiver & 1 Data Transceiver Card 

Module 

M

u

lt

i-

M

o

d

e

 

FT410DB-SMT 

Multi-mode 4-Ch. Video Transmitter & 

1 Data Transceiver Card Module 

FT410DB-SMR 

Multi-mode 4-Ch. Video Receiver & 1 

Data Transceiver Card Module 

1

 If the optical connector is FC type, the suffix in the model number will be 

“-

F

XX”.

 Eg. FT410DB-

F

ST 

2

 

FT-PA/12V works under 100 -240VAC, 50/60Hz power supply 

3

 Refer to FT-C18 product manual for specifications 

 

 

Содержание FT410DB Series

Страница 1: ...Digital Fiber Optic Manufacturing Specialists Installation and Operation Manual FT410DB Series 10 bit Digital Series 4 ch Video with 1 Bi directional Data Fiber Optic Converter OT Systems Ltd 2009 Rev...

Страница 2: ...ivers FT410DB SSRSA FT410DB SSRLSA Multi Mode Transmitter FT410DB SMTSA Multi Mode Receiver FT410DB SMRSA Card Modules Single Mode Transmitters FT410DB SST FT410DB SSTL Single Mode Receivers FT410DB S...

Страница 3: ...tandalone unit installation 6 3 3 Card module installation 6 4 CABLE CONNECTIONS SETUP PROCEDURES 7 4 1 System cable connections 7 4 2 Data port assignment and pin connections 9 4 3 Dip switch setting...

Страница 4: ...Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing opera...

Страница 5: ...TDM technology is employed for digital transmission of forward video and data whereas optical Wavelength Division Multiplex WDM technology is employed for simultaneous reverse data transmission as wel...

Страница 6: ...nsmitter 1 Data Transceiver Standalone Unit FT410DB SMRSA Multi mode 4 Ch Video Receiver 1 Data Transceiver Standalone Unit Card Modules Single Mode FT410DB SST Single mode 4 Ch Video Transmitter 1 Da...

Страница 7: ...be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture either on the wall or on a flat surface with four screws through the holes on the mounting fra...

Страница 8: ...front and back panels of the card modules are lit If not check the power supply cable connections between the chassis and the power supply socket For failures of individual card s POWER LEDs check the...

Страница 9: ...tion Manual www ot systems com 8 Standalone Transmitter Card Module Receiver Fig 4 2 Standalone unit to Card Module connection diagram Card Module Transmitter Card Module Receiver Fig 4 3 Card Module...

Страница 10: ...gram Transmitter End Receiver End User s Equipment DATA PORT 7 PIN DATA PORT 7 PIN User s Equipment TX 1 IN 1 IN TX TX 2 IN 2 IN TX RX 3 OUT 3 OUT RX RX 4 OUT 4 OUT RX 5 N A 5 N A 6 N A 6 N A 7 N A 7...

Страница 11: ...6 OUT RX Sig COM 7 Sig COM 7 Sig COM Sig COM Fig 4 4 3 Connector Pin Assignments for RS232 data format at Data port 4 3 Dip switch setting procedures The only setup procedure is to select the appropr...

Страница 12: ...input and output lines terminated in the ONE Tx to ONE Rx configuration For RS485 2 4 wire communication the RS485 device can be disabled to stay in a Hi Z state It is very important that the data lin...

Страница 13: ...ge caused by lightning and other power surges as well as a connection to the surge suppresion devices in the product a screw terminal is provided on the Standalone cabinets Fig 4 7 It is highly recomm...

Страница 14: ...tical Connector for fiber cable connection VIDEO IN BNC Video Connectors for video signal inputs DATA 7 pin Screw Terminal Block for data signal 5 2 FT410DB Series Receiver LED Indicators Indicator Co...

Страница 15: ...in 1 typical Differential Phase 1o typical SNR 65dB DATA Channel Connector 1 7 pin Screw Terminal Direction Bi directional Duplex Electrical Format RS232 RS422 RS485 2 wire 4 wire Tri state Transmissi...

Страница 16: ...refer to the OT Systems Products Warranty Statement for details Access to the statement is available in our company website at www ot systems com 9 Contact Information OT Systems Ltd Hong Kong Unit 10...