OSTBERG HERU 14 S AC Скачать руководство пользователя страница 2

W A R R A N T Y

Warranty period valid according to purchase contract
calculated from date of purchase.

S C O P E   O F   W A R R A N T Y  

This warranty covers faults occurring during the war-
ranty period, which have been notified to the dealer
or verified by Ostberg Americas Inc. (warrantor) or a
representative of the warrantor, and which concern
design, manufacturing or material defects and conse-
quential damages occurring on the product itself.
The above mentioned faults will be rectified so that
the product is made operational.

G E N E R A L   W A R R A N T Y   L I M I T A T I O N S

The warrantor’s responsibility is limited in accordan-
ce with these warranty terms and the warranty does
not cover property damage or personal injury. Verbal
promises made in addition to this warranty agree-
ment are not binding for the warrantor.

W A R R A N T Y   L I M I T A T I O N S  

This warranty applies on condition that the product
is used in a normal fashion or under comparable circ-
umstances for its intended purpose and that the
instructions for use are followed.

This warranty does not cover faults caused by:
- Transport of the product.
- Careless use or overstraining of the product.
- Failure on the part of the user to follow instruc-

tions concerning installation, use, maintenance, 
care and handling.

- Incorrect installation or incorrect positioning of 

the product.

- Conditions that are not due to the warrantor, e.g. 

excessive voltage variations, lightning, fire and 
other accidents.

- Repair, maintenance or design changes made by 

an unauthorized party.

- Faults that do not impact operation, e.g. surface 

scratches.

- Parts that through handling or normal wear are 

exposed to greater than average hazard, e.g. lamps, 
glass, ceramic, paper and plastic parts, and filters 
and fuses are not covered by the warranty.

- Settings; information on use, care, handling, service 

or cleaning that are customarily described in the 
instructions for use; or works caused by the user 
neglecting to observe warning or installation 
instructions; or investigation of such are not 
covered by the warranty.

- The warrantor is responsible only for the operation 

if approved accessories are used. 

- The warranty does not cover product failures 

caused by accessories/equipment from other 
manufacturers.

The unit’s current settings must be noted in the
installation/mounting instructions at installation to
avoid costs in the event of fault. The warrantor is not
liable for costs such as adjustment costs related to
the replacement of fans and control boards in the
unit.

S E R V I C E   T E R M S   D U R I N G  
T H E   W A R R A N T Y   P E R I O D

According to your agreement with your local distri-
butor.

R E C T I F I C A T I O N   M E A S U R E S  
W H E N   A   F A U L T   I S   D E T E C T E D

When a fault is detected, the customer must notify
this to the dealer. Specify what product this applies
to (part number and manufacture date – year and
week – are listed on the product label), and describe
the fault and how it occurred as accurately as pos-
sible. For a warranty repair to be performed, the cus-
tomer must prove that the warranty is valid by pre-
senting the receipt of purchase. After the warranty
period has expired, warranty claims that have not
been made in writing before the expiration of the
warranty period will not be valid.

In all other respects according to our conditions 
of sale.

N O T E !

Ostberg Americas Inc. reserve the right to make
changes without further notice.

Содержание HERU 14 S AC

Страница 1: ...UL VERSION Choose language and unit system in the Setting Menu on page 15 Installation and directions for use HERU S AC...

Страница 2: ...through handling or normal wear are exposed to greater than average hazard e g lamps glass ceramic paper and plastic parts and filters and fuses are not covered by the warranty Settings information o...

Страница 3: ...U 15 23 PRESSURE INPUTS FILTER MEASUREMENT AC FAN SETUP 16 DISPLAY CONTRAST BOOST OVERPRESSURE MAX TEMPERATURE 17 ALARM 18 CO2 RH HEATER 19 COOLER SUPPLY LIMITS REGULATION MODE MODBUS 20 SUMMER COOLIN...

Страница 4: ...dity efficiency of up to 85 The HRV exchanger has a temperature efficiency of up to 85 has backward curved centrifugal fans with main tenance free external rotor motors which are con nected with quick...

Страница 5: ...tside temperatures S E C U R I T Y Caution Do not apply electric power until after completion of the installation Ensure the installation and wiring is in accordance with CEC NEC and local electrical...

Страница 6: ...e of the risk of injury we do not recommend installing the unit vertically C or with the lid downwards D Allowances must be made to access the unit for servicing or maintenance A B C D Inch A D B C H...

Страница 7: ...s supplied for right handed application see picture below If the unit is installed left handed and no electrical heater is fitted changes can be made in the Service Menu and in the sub menu Flow Direc...

Страница 8: ...8 C O N T R O L D I A G R A M H E R U S shows all sensors flow direction right Accessories...

Страница 9: ...N C A PA C I T Y Airflow fan speed is regulated via the week timer that can be programmed for specific time points when the fan speed should change from one speed to antoher e g home or away setting A...

Страница 10: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harm ful interference to radio communications However there...

Страница 11: ...m Relative air humidity in per cent Carbon dioxide level in PPM part per million SYMBOLS THAT CAN BE DISPLAYED IN VIEW MODE 3 Press key to choose Boost off on of the supply exhaust air flow for a spec...

Страница 12: ...time has the factory setting of 30 min and fan speed Medium To adjust the fan speed and time see page 17 Boost is activated disable On Off with the key F A N S P E E D M E N U Only for HERU AC T E M...

Страница 13: ...rd Medium Max Standby and temperature 15 30 C 59 86 F Overpressure is a special feature were you can pressure compensate when supplementary heating using an open fire or stove The exhaust air fan then...

Страница 14: ...have the possibility of turning off the unit via the wireless control unit NB The unit must be currentless during service and maintenance Press in order to go forward from the Main Menu Press in order...

Страница 15: ...em Press and then in order to choose Confirm with Choose from Metric and Imperial 15 W Week timer Power On Off U Unit system Imperial Unit system Imperial T H E S E R V I C E M E N U In this menu a pa...

Страница 16: ...s ker B r endast ndras av installat r Minimum Min 20 EC motor setup EC motor setup Standard Standard Min Medium Medium Avbryt Ok Standard konst tr Till 90Pa 45 Fr n 110Pa 50 Till konst tr EC motor set...

Страница 17: ...be activated at the View mode 1 and 2 and in the Main Menu Boost Press in order to go forward from the Main Menu Press again and then in order to choose the desired duration 10 240 min with the inter...

Страница 18: ...crease the temperature can be change from 5 to 12 C 41 to 54 F but have to be higher than Alarm limit A If the unit operating at Min speed the extract air increases one step In menu Fire sensor type o...

Страница 19: ...der to choose the Limit value 500 1400 PPM Press again and then in order to choose Interval 1 10 min At levels above the limit value the fan speed will increase one step according to the set Interval...

Страница 20: ...on wireless control unit Version wireless control unit activates the Modbus port on the control board and the ability to communicate via RS485 For this you need complete Modbus index that you can down...

Страница 21: ...Press again and then in order to choose InOutDiff 1 10 C 34 50 F Extract HI 19 26 C 66 79 F and Extract LO 18 24 C 64 75 F S E R V I C E M E N U S U M M E R C O O L I N G If Summer Cooling On is chose...

Страница 22: ...M E N Y V E R S I O N I N F O Displays the software version of the unit Heru and the wireless control RC Press again to see the version S E R V I C E M E N U L O A D S A V E S E T T I N G S Load Save...

Страница 23: ...has been used in an earlier assembly it will say Synchronize instead of Start Synchronization option Disconnect the power to the unit Press the reset button on the control board small square button ab...

Страница 24: ...ips When changing filters once a year it is also appro priate to check if the fans are dirty Remove the the fans and rotor s protective plates when the fans have stopped and the heater has co oled The...

Страница 25: ...en the ground cable 9 6 Pull out the rotor motor from the grippers and then dismount them 7 For HERU 35 52 S loosen electrical socket with bracket 12 with screwdriver TX20 and hang it over the egde to...

Страница 26: ...00102 Outside wall hood 200 mm black 8200103 Outside wall hood 200 mm white 8200104 H E AT I N G C O I L 5 0 k W C O O L I N G C O I L 2 5 k W Air Flow 424 CFM 318 CFM Speed 2 2 m s 1 7 m s Temp in 77...

Страница 27: ...gfilter F7 the same for supply and exhaust air HERU 52 S 1250153 Fan HERU 14 S AC 7710256 Fan HERU 19 S AC 7710255 Fan HERU 35 S AC 7710258 Fan HERU 52 S AC 7710253 Fan HERU S 7710249 Fan HERU S 77102...

Страница 28: ...68...

Страница 29: ...69...

Страница 30: ...Filter If filters are dirty Change filter If the set time for filter measurement is reached Change filter Sensor open Which sensor is triggered see page 14 Connection to relay card If error remains ch...

Страница 31: ...ulation mode Constant Supply reg Extract reg Room reg Default Const supply reg InOutDiff 1 10 C 34 50 F Default 5 C 41 F Extract HI 19 26 C 66 79 F Default 24 C 75 F Extract LO 18 24 C 64 75 F Default...

Страница 32: ......

Страница 33: ...33 DIMENSIONS 34 FLOW DIRECTION 35 TECHNICAL DATA 35 SOUND DATA 36 37 PRESSURE FLOW DIAGRAMS 38 39 WIRING DIAGRAMS 40 41 T E C H N I C A L I N F O R M AT I O N 34 41...

Страница 34: ...16 4811 16 444 8 515 16 161 4 8 287 32 2613 16 5313 32 497 32 65 16 1913 32 13 13 32 7 23 32 10 217 8 205 8 423 8 381 4 5 145 8 10 1 16 5 9 16 6 18 5 8 22 5 8 27 H E R U 5 2 S A C H E R U 3 5 S A C H...

Страница 35: ...n of Sound pressure level HERU 14 S HERU 19 S HERU 35 S HERU 52 S Voltageg V Hz 120 60 120 60 120 60 120 60 Current fans A 2 fans 1 39 2 34 3 67 4 14 Current total A 11 5 12 4 17 9 18 4 Power fans W 2...

Страница 36: ...0 m2 vilket ger att LpA LwA 7 Q 4 4pr2 AEkv The sound data have been compiled by means of sound measurement methods as fol lows Pressure and flow SS ISO 5801 Determination of acoustic sound power leve...

Страница 37: ...Surrounding 32 39 27 34 30 29 33 25 27 26 Supply 56 49 46 50 50 46 43 40 30 Extract 50 41 44 45 42 41 30 26 18 H E R U 5 2 S A C 120 V 328 CFM 1 20 H2O LpA LwATotal dB 63 Hz 125 Hz 250 Hz 500 Hz 1k H...

Страница 38: ...ogether H E R U 1 4 S A C H E R U 1 9 S A C PRESSURE FLOW PRESSURE FLOW TOTAL FAN POWER FLOW 70 75 80 85 90 TEMPERATURE EFFICIENCY TOTAL FAN POWER FLOW TEMPERATURE EFFICIENCY 1 2 3 4 5 6 7 50 V 65 V 7...

Страница 39: ...t air Indicated power applies to both fans together 1 2 3 4 5 6 7 50 V 65 V 75 V 85 V 95 V 105V 120 V PRESSURE FLOW TOTAL FAN POWER FLOW TEMPERATURE EFFICIENCY TRANSFORMER STEP TRANSFORMATORSTEG PRESS...

Страница 40: ...W I R I N G D I A G R A M 4 0 4 0 1 5 5 HERU 14 S AC 19 S AC 40 Fan motor Fan motor Fan motor Yellow green Black Blue Brown White Orange Grey Green Violet Yellow...

Страница 41: ...W I R I N G D I A G R A M 4 0 4 0 1 4 9 HERU 35 S AC 52 S AC 41 Fan motor Fan motor Fan motor Yellow green Black Blue Brown White Orange Grey Green Violet Yellow...

Страница 42: ......

Страница 43: ......

Страница 44: ...1270316 UL Utg 3 OSTBERG AMERICAS INC 55 Raglin Place Unit 3 Cambridge ON N1R 7J2 Ph 519 623 6363 Fax 519 623 8543 www ostberg com...