Requirements Of Cable Bending And Twisting
Please take EXTRA precautions before bending or twisting ARCHISHAPE
®
2.0 Dot S/M/L cable. Lead Cable must
NOT be bent below the Minimum Bending Radius (4x Cable Diameter) and the Non-Bendable Length of 50mm /
2” near the connector end or near the cable overmold MUST be adhered to.
FIG.7: Minimum Cable Bending and Non-Bendable Length Requirement
(Non-Bendable Length)
500mm (19.69")
≥
4D
(Minimum Bending Radius)
14mm/0.55”
20mm/0.79”
D
Ø7mm/0.28”
50mm/1.97”
(Minimum Bending Radius)
28mm/1.00”
≥
4D
The flat ARCHISHAPE
®
2.0 Dot S/M/L Cable must NOT be bent/twisted below 20mm (0.79”) from edge of
ARCHISHAPE
®
2.0 Dot S/M/L housing (Non-Bendable/Non-Twistable Length).
Twisting the flat cable is NOT recommended. If twisting is necessary for installation, please adhere to the Non-
Twistable Length specified in Fig. 6 and ensure the mounting pitch is greater than or equal to 75% of the normal
ARCHISHAPE
®
2.0 Dot S/M/L to ARCHISHAPE
®
2.0 Dot S/M/L pitch. The middle part of the cable must be
secured to the mounting surface with a cable tie (see “3.3 On-Site Installation” on page 12 and FIG.11 on page
14). Ensure no damage is generated on the cable.
FIG.8: Minimum Clearance
20mm/0.79”
Minimum clearance
from dot
Non-Bendable/
Non-Twistable Length
NOTE: Water ingress incurred due to excess cable bending/twisting will not be warrantied by Traxon Technologies.