Osram SYLVANIA Series Скачать руководство пользователя страница 6

 

Industry Relations & Standards 

 

Document No.: 

Revision No.:

 

Issue Date: 

DQ4-144-067

 

09-08-2006 

Subject:  Warning – Metal Halide Display/Optic Lamps [HMI, HMD, HMP, HSD, HSR, HTI, HCD] 

 

 

 

 

 

Please verify that you have the latest revision prior to use.  Do not use if outdated. 

H/Warnings/OSRAM/MHID.doc 

Printed on: 9/29/2006 9:21:00 AM   

 

Page 6 of 6

 

 

OSRAM metal halide lamps have the following mercury contents: 

 

Lamp Family 

Maximum Mercury Content (mg) 

 

 HMI 

1200 

 HMP 

70 

 HTI 

340 

 HSR/HSD 

130 

 HMD 

520 

 HCD 

23 

 

PROPERTIES OF MERCURY: 

 

Chemical symbol: 

Hg 

 

Atomic number: 

80 

 

Molecular Weight: 

200.59 

 

Density: 13.6 

g/cm

3

 @ 20°C / 68°F 

 

Melting Point: 

-39°C / -38.2°F 

 

Boiling Point: 

357°C  / 674°F 

 

Vapor pressure: 

160 Pa @ 20ºC / 68ºF 
370 Pa @ 30ºC / 86ºF 
823 Pa @ 40ºC / 104ºF 

 

Concentration in air: 

13.6 mg/m

3

 @ 20ºC / 68ºF 

29.6 mg/m

3

 @ 30ºC / 86ºF 

62.7 mg/m

3

 @ 40ºC / 104ºF 

 

CAS Registry Number:  7439-97-6 

 

RCRA waste number:  U151 

 

Other Names:  Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, 
Quecksilber, Quick silver, Liquid Silver 

 

LAMP DISPOSAL: 

1.  Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations.  

State laws may differ in their disposal requirements for lamps. 

2.

 

Lamp users in North America may obtain specific state or province information concerning disposal regulations, 
toll-free, by calling 1-866-666-6850.  

3.  OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for 

federal, state/provincial, and/or local municipalities.  It is the responsibility of the waste generator to ensure 
proper classification and disposal of waste products.  

 