2.   Installation

2.1  Points to Consider

Plan your installation before mounting ProPoint Kontour RGB / RGBW / White.

The following should be considered for a successful installation:

 

Weather conditions and ambient temperature of installation site.

 

Installation distances and appropriate cable lengths. Please consult your local Traxon™ office or authorized 

agent for necessary aid.

 

The number of ProPoint Kontour and Data Injectors and appropriate power sources.

 

DMX512 controller to be used to control the ProPoint Kontour.

 

Distance between each ProPoint Kontour for thermal expansion.

 

Proper surge protection.

 

If not beginning installation at the Data Injector, ensure that the layout of the luminaire input and output 

connections are in the correct orientation.

2.2  Pre-Installation Checks

2.2.1  

Installation Checklist

1. 

Perform visual check of 

ProPoint 

Kontour. Take care not to damage cables/connectors during pre-installation 

checks.

2. 

Prepare cables and all necessary accessories (mounting brackets, temporary waterproof end caps etc).

3. 

Connect the luminaires, data injectors and power supplies in accordance with the wiring diagram.

4. 

Report any functional defect found to your nearest Traxon Technologies office. DO NOT attempt to install a 

ProPoint 

Kontour with functional defects on-site.

5. 

Ensure all pre-installation checks laid out below have been followed.

6. 

If this installation is to be left in an incomplete state overnight, ensure that all connectors and cables are 
properly protected using dust/end caps as required. Any unused materials should be left in an indoor 
environment.

a.  Ensure that all connected ProPoint Kontour fixtures/data injectors outdoors with an open connector are 

secured with an end cap (purchased separately) to keep all ports sealed.

b.  Ensure all of the Interconnection Cables, ProPoint Kontour, and Data Injectors are initially stored in a dry 

area to guarantee the complete sealing of the system from water before installation.

2.2.2  

Cable Bending

The cable bend radius must NOT be less than the minimum bending radius (4 x Cable Diameter) as 
specified by the cable manufacturer and the non-bendable Length of 5cm (1.97”) near the connector 
end MUST be adhered to. In addition to the minimum bending radius, ensure that 5cm (1.97”) of cable 
at the connector junction is kept straight – see image below:

To reduce stress induced on the ProPoint Kontour cable and connector, please adhere to the Minimum 
Bending Radius of 50.4 mm (2”) and the non-bendable length of 50.4mm (1.98”) near the connector. It 
is recommended to install lead cables through conduits/trunking.

Содержание ProPoint Kontour Flat Narrow

Страница 1: ...ProPoint Kontour INSTALLATION GUIDE V1 0 Cover ProPoint Kontour Flat Narrow ProPoint Kontour Flat Wide ProPoint Kontour Round Narrow ProPoint Kontour Round Wide...

Страница 2: ...F TRAXON TECHNOLOGIES U S PATENTS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide V1 0 03 21 P 2 of 26 CONTENT 1 Introduction 4 2...

Страница 3: ...ere weather conditions Do not stare directly into the light beam while the unit is illuminated IP66 rated The ProPoint luminaire is not suitable for direct immersion in water Do not operate the ProPoi...

Страница 4: ...th DMX512 versions of the ProPoint Kontour Model Length Power Consumption Typ Available PXL Configuration ProPoint Kontour Narrow 300mm 12 4W 300mm can be 1PXL 600mm can be 1PXL or 2PXL 1200mm can be...

Страница 5: ...21 P 5 of 26 1 2 Getting Assistance Additional product information is available on the Traxon web site www traxontechnologies com www osram us traxon For additional support please contact Traxon Techn...

Страница 6: ...mm 1 9 47 4mm 1 9 47 4mm 1 9 47 4mm 1 9 47 4mm 1 9 73mm 2 9 58mm 2 3 69 5mm 2 7 44mm 1 7 47 4mm 1 9 300mm 11 8 75mm 3 100mm 3 9 130mm 5 1 Power Data Input side Power Data Output side 600mm 23 6 15mm 0...

Страница 7: ...5 9 5mm 0 4 75mm 3 89 4mm 3 5 70mm 2 8 Without Mounting Bracket 75mm 3 75mm 3 75mm 3 75mm 3 300mm 11 8 75mm 3 100mm 3 9 130mm 5 1 Power Data Input side Power Data Output side 600mm 23 6 15mm 0 6 250m...

Страница 8: ...ew Luminaire Options The ProPoint Kontour is available in the following sizes Model Model Power Consumption Typ Power Factor Input Voltage Range Operating Temperature Narrow 300mm 12 4W 0 9 120 277V A...

Страница 9: ...36A 72A 108A n 36A 0 05ms 1200mm 48 NW WD 21 4A 42 8A 64 2A n 21 4A 0 8ms 2400mm 96 NW 21 4A 42 8A 64 2A n 21 4A 0 8ms 2400mm 96 WD 24A 48A 72A n 24A 0 8ms The ProPoint Kontour is available with the...

Страница 10: ...c 3 Connect the luminaires data injectors and power supplies in accordance with the wiring diagram 4 Report any functional defect found to your nearest Traxon Technologies office DO NOT attempt to ins...

Страница 11: ...tlined in the system diagram wiring diagram to form a complete chain 4 Perform a visual check of the complete system to ensure all parts of the system are properly connected 5 Perform a functional che...

Страница 12: ...9 380mm 15 395mm 15 6 15mm 0 6 Interconnection Limitation 300mm 12 Kontour cannot be connected end to end with any other Kontour luminaire and achieve the minimum distance of 4mm 0 16 spacing between...

Страница 13: ...inimum distance of 4mm 0 16 spacing between fixtures This however requires a customized version of the 2400mm 96 with a shortened input cable output cable or both depending on project needs If wiring...

Страница 14: ...rface hardware not included Screw driver type M3 hex driver M3 Screw included 2 Unplug the dust caps waterproof end caps and keep them safe for future use 3 Fully connect all ProPoint Kontour connecti...

Страница 15: ...l expansion Power Data output side Power Data input side 4 Attach the terminator end cap on last ProPoint Kontour in run 2 4 Accessories Installation Safety Wire Installation Method 1 Affix safety cab...

Страница 16: ...t Use provided end cap for final data injector in chain 3 pin Female connector Female connector Cable A DATA OUT DATA IN POWER IN TO FIXTURE Use Kontour end cap w Terminator PP AC 600000 for final fix...

Страница 17: ...nput Voltage Max Connected Chain 300mm 12 4W 120V 432 600mm 24 8W 120V 216 1200mm 48 16W 120V 108 2400mm 96 32W 120V 54 277V Model Power Consumption Typ Input Voltage Max Connected Chain 300mm 12 4W 2...

Страница 18: ...90155 Cable B KO KB 602000 2M Kontour PWR DATA INT CBL CE AM357500155 Cable B KO KB 603000 3M Kontour PWR DATA INT CBL CE AM357510155 Accessories ETL Cable Type Model No Description Item Code Cable A...

Страница 19: ...auto addressing only and does not support manually assigned address Each Data Injector consumes 512 DMX channels regardless of connected fixture count Maximum number of Data Injector units per DMX 512...

Страница 20: ...injury or property damage Do not use product s if cables are damaged Do not connect cables and connectors when wet or in wet area Moisture on bare connectors can cause electric shock and damage to pro...

Страница 21: ...9 lbs 2 1 kg 4 6 lbs 3 8 kg 8 4 lbs EPA sq ft Front 0 032 Side 0 258 0 392 0 787 1 575 Front 45 0 1824 0 2771 0 5564 1 1135 ProPoint Kontour Flat Wide RGBW 300mm 12 600mm 24 1200mm 48 2400mm 96 Color...

Страница 22: ...mm 12 600mm 24 1200mm 48 2400mm 96 Color Range 3000K 4000K Standard 2200K 2700K 3500K 5000K 6500K Red Green Blue Amber available Power Consumption 5W 10W 20W 40W Weight 1 1 kg 2 4 lbs 1 5 kg 3 3 lbs 2...

Страница 23: ...5W 10W 20W 40W Weight 1 35 kg 2 98 lbs 1 86 kg 4 10 lbs 3 11 kg 6 86 lbs 5 42 kg 11 95 lbs EPA sq ft Front 0 078 Side 0 392 0 630 1 173 2 348 Front 45 0 2771 0 4454 0 8293 1 6600 ProPoint Kontour Rou...

Страница 24: ...e rate of LED degradation is a complex function of many factors such as operating efficiency duration of continuous operation and operating conditions e g ambient temperature Because LEDs are semicond...

Страница 25: ...source Modules are dim Excess products connected Ensure the data injectors are not overloaded due to an excess of products connected Flickering Incorrect power input Excess products connected Ensure...

Страница 26: ...heck for the latest updates and changes on the Traxon website 2021 TRAXON TECHNOLOGIES ALL RIGHTS RESERVED Information is subject to change without prior notice www traxontechnologies com www osram us...

Отзывы: