![Osram AB444210035 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/osram/ab444210035/ab444210035_setup-manual_1656606015.webp)
15
Network configuration
4.5
Power supply
The e:cue SYMPL e:bus Node can be powered by an external power
supply or via Power-over-Ethernet.
PoE:
For PoE, simply connect an Ethernet connection from a power sourcing
device.
External power supply:
Connect the SYMPL e:bus Node to a certified
NEC
Class 2 24 V DC power
supply unit. Present power supply equates to the status “On” or running of
the SYMPL Node.
To connect the device to a power supply unit, use the provided 2-pole
terminal and lay the wires as stated on the front label. The voltage
assignment is left V+ and right V-.
Turn the power on when all cables are connected to the
SYMPL e:bus Node. The device starts booting. The device has finished
booting and is in operation when the LED Status is flashing.
5
Network configuration
The configuration of the e:cue SYMPL e:bus Node is done via e:cue
SYMPHOLIGHT. See the SYMPHOLIGHT System Manual for details on
configuration, available at www.ecue.com.
The network properties of the SYMPL e:bus Node are preconfigured. The
successful installation of the power supply is required for changing the
!
The SYMPL e:bus Node is not suited for powering over a DC
power supply network. Use a separate certified SELV Class 2
power supply unit in the control cabinet for supplying 24 V
DC to the SYMPL e:bus Node.