Osram 58289 Скачать руководство пользователя страница 5

Decorator Plate Installation

The tunable white wallstation can also be installed with an off-the-shelf  
decorator-style wall plate. Multi-gang wallstation installations require  
multi-gang decorator wall plates.  
Remove the button assembly from the OSRAM wall plate. This can be achieved 
by pressing the wall plate with your thumbs near the button assembly while 
grasping the OSRAM Wall Plate.
Install the supplied wall strips to the button assembly until they snap in.

Orient the mounting bracket such that the DECORATOR and MULTI GANG  
labels are facing up. Using MULTI GANG orientation with decorator plate  
ensures that the wallstation sinks deep enough into the wall. This allows the 
decorator plate to be flush to the wall surface. Insert the wallstation button  
assembly into the mounting plate until ‘clicks’ are heard. Clicks confirm that  
the pieces are secured.   

5

Содержание 58289

Страница 1: ...OSRAM Tunable White Wallstation Wiring and installation manual www osram us ds Light is OSRAM...

Страница 2: ...found on page 8 of this manual It is powered by the DALI power pack 58290 Important Safeguards Note Tip STOP When using electrical equipment basic safety precautions should always be followed includin...

Страница 3: ...sh to the wall surface the mounting bracket should be installed in MULTI GANG orientation with Low Voltage Device Box 3 Mounting Bracket J Box Wallstation Installation Electrical Metal Device Box Inst...

Страница 4: ...4 Wallstation Installation continued Place the wallstation assembly into the mounting plate and push gently until clicks are heard This confirms that the pieces are secured 115 4...

Страница 5: ...ar the button assembly while grasping the OSRAM Wall Plate Install the supplied wall strips to the button assembly until they snap in Orient the mounting bracket such that the DECORATOR and MULTI GANG...

Страница 6: ...Install the mounting bracket using the supplied screws Install the decorator plate using screws supplied with the decorator plate 6...

Страница 7: ...wallstation and communication to and from the wallstation is achieved using these two wires only Right two ports are dum my and should not be used AWG 18 is recommended Please refer to LMS168 on how...

Страница 8: ...nt buttons when in the factory default mode To save a custom scene setting obtain the desired brightness and color level using the Brightness and Color button respectively After desired level is achie...

Страница 9: ...e designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy...

Отзывы: