Display of current secondary (DHW) temperature
Press key (8)
down
once and release to display current secondary (DHW)
temperature. The value is shown for 5 s, after which display reverts to actual
primary temperature in the boiler.
Setting pump overrun for secondary (DHW) water
Press key (8)
down
and hold for 5 seconds to set pump overrun of secondary
(DHW) water
The time for secondary (DHW) pump overrun blinks.
Press key (8) up and down to change time from 0.1 min up to 1.9 min. with the
step of 1 digit. If there is no pressure on the key for more than 5s, the value from
a display is saved as time for secondary (DHW) pump overrun.
Factory default overrun is 1 min.
Setting stand by primary temperature inside boiler
Press the key (8)
down
and hold for 10 seconds to set stand by primary
temperature inside boiler.
LED display will show current stand by primary temperature inside boiler.
Press key (8) up or down to change stand by temperature in range from 10°C to
50°C , by 1°C. If there is no pressure on the key for more than 5s, the value from
a display is saved as stand by primary temperature inside boiler.
Displaying software version and factory reset
>5 sec
1.0
36
>5 sec
>10 sec
>5 sec
20
32
>5 sec
<5 sec
>15 sec
1.4
Press the key (8)
down
and hold for 15 sec, LED will show software version and
factory reset of central heating parameters will occur.