2. INSTALLATION

 2.1  Health and safety regulations

Handling Operations Regulations 1992 defines 

manual handling as: “any transporting or support-

ing of a load (including the lifting, putting down, 

pushing, pulling, carrying or moving thereof by 

hand or bodily force”. The Regulations set no spe-

cific requirements such as weight limits. However 

common sense still has to be used based on an 

ergonomic approach for each individual. 

The Super SC should be transported and stored in 

a vertical position.

2.2 Siting the Slimline 

The cylinder should not be positioned un-

til the connecting pipework and cables are 

 

fitted. There are few restrictions on the siting of the 

OSO Slimline, however it should not be sited any-

where open to frost attack. 

The unit should be placed on a stable flat surface 

capable of withstanding the weight of the cylinder 

when full and access must be allowed for mainte-

nance purposes. Provision should also be allowed 

for the routing of the discharge pipe away from the 

cylinder to an outside point according to building 

regulation G3. 

2.3 Component check list

Components supplied with the unit in a separate 

accessory kit for site fitting:

• 

Expansion vessel with wall bracket

• 

Pressure reducing valve multibloc 3 bar with 

expansion relief valve 6 bar

• 

Motorized valve

• 

Tundish (incl. screws)

• 

Plastic cable clamp

• 

Drain cock

Components factory fitted:

• 

P&T valve

• 

Immersion heater - 3 kW

• 

Thermostat(s) / thermal cut-out

Documentation supplied:

• 

Installation manual & service logbook

2.4 Supply requirements

An uninterrupted 22 mm cold water mains supply 

is recommended, however if only a 15 mm supply is 

available, this may be used provided there is suffi-

cient flow rate available. A minimum standing pres-

sure of 2.5 bar and a flow rate of 20 litres per minute 

with a 1 bar dynamic pressure is recommended. The  

cylinder will operate at lower pressures and flow 

rates however the performance will be compro-

mised. The OSO unvented unit is designed for use 

with supply pressure up to 8 bar. For pressures 

over 8 bar an additional pressure reducing valve 

must be fitted in the supply pipe to the unit.

2.5 Expansion  vessel

An expansion vessel with wall bracket and flexible 

hose is supplied with unit. The vessel accommo-

date expanded water when the cylinder is heated 

and prevents the cylinder reaching its maximum 

working pressure.

2.6  Preliminary wiring

Before final installation and pipe fitting it is rec-

ommended to feed the electrical wires to the 

electrical box. The OSO Slimline is supplied with 

all internal wiring factory fitted and a connection 

cable with strain reliever fitted to the top of the 

outer casing. 

For more information about electrical installations 

see chapter 4. ELECTRICAL INSTALLATION. 

 2.7  Pipework

Cold water supply:

1.  To obtain the best performance from your 

OSO unvented system it is advisable to feed 

the unit with an uninterrupted supply.

2.  Before connecting to the multibloc, flush the 

cold supply pipework of all flux and debris.

3.  Locate the water heater in a suitable position 

to facilitate the installation of the cold water 

supply, discharge fittings and pipework. Also 

take into account access to the immersion 

heater.

4.  Fit the combined male elbow drain cock to 

cold supply point so that the compression 

fitting is vertical.

5.  Fit a length (1280 mm) of copper tube 22 

mm to the cold feed elbow to include a Tee 

piece if a secondary return is required

6.  Fit the Pressure Reducing Valve to the top of 

the copper tube.

7.  Connect 15 mm copper tube from the expan-

sion relief valve (4) and also from the T & P 

valve (5) and join together in a Tee as shown 

Содержание Slimline-RI 150

Страница 1: ...y OSO Hotwater AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 Fax 47 32 25 00 90 E mail oso oso no www osohotwater com Slimline RI 150 l EN SAFETY INFORMATION O M INFORMATION INSTALLATION...

Страница 2: ...4 5 S plan wiring layout 12 4 6 Y plan wiring layout 13 5 Maintenance safety and servicing 5 1 Draining flushing 14 5 2 Recommissioning 14 5 3 Safety and maintenance 14 5 4 Corrosion resistance 14 5 5...

Страница 3: ...hould be filled with water before the power is switched on Maintenance settings should only be carried out by persons over 18 years of age with sufficient understanding CAUTION The product must not be...

Страница 4: ...ssioning of the cylinder This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented unit OSO Slimline cylinders are not suitable for gravity fed prim...

Страница 5: ...ently frost free position The product should be placed on a floor or wall suitable for the total weight of the prod uct when in operation See type plate The product must have a clearance for servicing...

Страница 6: ...m standing pres sure of 2 5 bar and a flow rate of 20 litres per minute with a 1 bar dynamic pressure is recommended The cylinder will operate at lower pressures and flow rates however the performance...

Страница 7: ...s tee 9 If a balanced mains pressure cold water supply is required to a shower or bidet over rim type only remove the blanking cap from the pressure reducing valve 3 and connect to the shower or bidet...

Страница 8: ...pi cally be 82 C 16 For electrical connection of the motorised valve and immersion heater please read Electrical Installation Instructions Tundish 17 Install the Tundish 6 in a vertical position withi...

Страница 9: ...low 2 port valve supplied Zone valve not supplied Automatic bypass Radiators UFH Boiler Pump flow 2 port valve supplied Mid pos valve not supplied Radiators UFH Boiler Automatic bypass S plan piping d...

Страница 10: ...ng System flushing will not be necessary under nor mal circumstances as the line strainer will prevent ingress of foreign materials however if flushing is required run at least 50 litres of water from...

Страница 11: ...torized valve To comply with regulations governing the in stallation of indirect unvented cylinders a mo torised valve must be fitted in the primary flow or return Your OSO unit has been supplied with...

Страница 12: ...10 RESE T R E S E T M2 1 2 3 4 RESE T R E S E T M2 1 2 3 4 1 2 E 2 3 1 T6360B B1 Br G O G Y 3 5 7 3 4 N L E N L E N L ST6400 Boiler Pump 3 2 1 3 2 3 2 2 2 3 1 V4043H Room thermostat Zone Valve DHW sup...

Страница 13: ...ed 6 W B1 G Y Gr O 2 3 V4073A1039 10 4 5 9 8 7 RESE T R E S E T M2 1 2 3 4 1 2 E 2 3 1 T6360B B1 O G Br G Y 3 3 1 4 N L E N L E N L ST6400 Boiler Pump 3 2 1 3 2 3 2 2 2 3 1 V4043H Room thermostat Zone...

Страница 14: ...cold water supply and open a ground floor cold tap 2 Unscrew the pressure reducing cartridge 3 Clean the filter mesh and the cartridge under running water 4 Replace cartridge ensuring that strainer is...

Страница 15: ...15 5 5 Spare parts Pressure reducing valve Cartridge Part No REDC 355030 3 bar Expansion valve Cartridge and seat Part No 214005 6 0 Bar Expansion valve Part No PREL 355030...

Страница 16: ...t When dis charge has stopped check thermal con trols and replace as necessary Cold water PRV incorrectly fitted Check and refit as required Intermittent water discharge If problem stil persists conta...

Страница 17: ...tions Check cylinder ther mostat is switch ing on off with programmer hot water on Is 2 port moto rized valve closing when cylinder reaches tempera ture Check wiring on cylinder thermostat Wiring faul...

Страница 18: ...to a roof capable of withstanding high tem perature discharges of water and 3 m from any plastics guttering system that would collect such discharges tundish visible Where a single pipe serves a numbe...

Страница 19: ...Regulations 3 Failure to install and commission this appliance to the manufacturer s instructions may invalidate the guarantee The above does not affect your statutory rights For full details on the H...

Страница 20: ...F DIFFERENT NAME DATE ADDRESS TEL No REGISTERED OPERATIVE ID CARD No IF APPLICABLE REGISTRATION DETAILS IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOGBOOK AND PASS IT ON TO THE CUSTOME...

Страница 21: ...IS THE PRESSURE REDUCING VALVE SETTING IF FITTED WHERE IS OPERATING PRESSURE REDUCING VALVE SITUATED NO YES NO YES NO bar HAS THE EXPANSION VESSEL OR INTERNAL AIR SPACE BEEN CHECKED YES NO WHAT IS THE...

Страница 22: ...al and all relevant Codes of Practice and Regulations in force at the time of installation The Product has not been modified in any way tampered with or subjected to misuse and no factory fitted parts...

Страница 23: ...ENTS SIGNATURE DATE ENGINEER NAME SERVICE 5 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 7 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 9 COMPANY NAME TEL No...

Страница 24: ...Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 oso oso no www osohotwater com This installation manual and all its content is protected by copyright and may be reproduced or distributed only...

Отзывы: